EEWORLDEEWORLDEEWORLD

Part Number

Search

MMSS-05-28C-S-03.25-D-K-MDS

Description
Interconnection Device
CategoryThe connector    The connector   
File Size188KB,3 Pages
ManufacturerSAMTEC
Websitehttp://www.samtec.com/
Environmental Compliance  
Download Datasheet Parametric View All

MMSS-05-28C-S-03.25-D-K-MDS Overview

Interconnection Device

MMSS-05-28C-S-03.25-D-K-MDS Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerSAMTEC
Reach Compliance Codecompliant
Connector typeINTERCONNECTION DEVICE
REVISION W
DO NOT
SCALE FROM
THIS PRINT
W
W
NOTES:
1.
C
REPRESENTS A CRITICAL DIMENSION.
2. BURR ALLOWANCE: .003[0.08] MAX.
3. PARTS TO BE MOLDED TO POSITION.
4. MINIMUM PULLOUT FORCE: 5 lbs [22.24 N].
5. CONTACT MUST BE INSERTED UNTIL RETENTION FEATURE LOCKS
INTO PLACE.
C
6. ALL FINISHED GOODS ARE TO BE ELECTRICAL TESTED INCLUDING
HI-POT TEST @ 1000 VOLTS DC. AFTER FINAL ELECTRICAL TEST,
LABEL EACH ASSEMBLY WITH 1 LABEL-ET.
7. TINNED COPPER WIRE CONTAINS LEAD.
8. PARTS ARE TO BE LAYER PACKAGED.
9. CONTACTS OFFSET FOR POLARIZATION.
C
10. REFER TO CRIMP SPECIFICATIONS PRINT FOR CRIMP AND STRIP
DIMENSIONS, TOLERANCES, TOOLING AND ITS REQUIREMENTS.
11. FOR LENGTHS LESS THAN 12 IN, TOLERANCE SHALL BE ±.125[3.18].
FOR OTHER LENGTHS, TOLERANCES SHALL BE ± 2%.
MMSSX-XX-XXX-X-XX.XX-X-X-XXX
FEP CABLE OPTION
-T: FEP INSULATION
(LEAVE BLANK FOR
STANDARD PVC INSULATION)
No OF POSITIONS
-02 THRU -25
WIRE GAUGE (AWG)
PVC:-20, -22, -24, -26, -28, -30
FEP:-20, -24, -28, 30
COLOR CODE
C (SEE TABLE 2)
(LEAVE BLANK FOR
STANDARD BLACK CABLE)
(NOT AVAILABLE WITH FEP OPTION)
PLATING SPECIFICATION
-F: FLASH SELECTIVE (USE C-179-XX-F)
-L: LIGHT SELECTIVE (USE C-179-XX-L)
-S: SELECTIVE (USE C-179-XX-S)
OPTION
SINGLE
-M: METAL LATCH (USE IPD1-XX-S-X-M)
(LEAVE BLANK FOR PLASTIC)
DOUBLE
[MUST BE USED ON -D END OPTION ONLY
& APPLIES TO END 2 HOUSING]
-LUS: PLASTIC LATCH UP, STRAIGHT
-LDS: PLASTIC LATCH DOWN, STRAIGHT
-MUS: METAL LATCH UP, STRAIGHT
-MDS: METAL LATCH DOWN, STRAIGHT
OPTION
-K: KEYED POLARIZATION
(USE IPD1-XX-S-K)
(SEE FIG 3, SHEET 2)
(LEAVE BLANK FOR NO POLARIZATION;
AVAILABLE TO EXISTING CUSTOMERS ONLY)
END OPTION
-S: SINGLE END
-D: DOUBLE END(MUST CHOOSE XUS OR XDS OPTIONS.)
ASSEMBLED LENGTH
SPECIFY IN INCHES [USE DWCX-XX-XX]
(SINGLE END: 03.00[76.2] INCH MINIMUM,
DOUBLE END: 03.25[82.6] INCH MINIMUM)
02 01
(No OF POS x .100[2.54])
+ .055[1.40] REF
C
L
.200 5.08
REF
.300 7.62
REF
.010 0.25 REF
(SEE NOTE 9)
"A"
IPD1-XX-S
.505 12.83
REF
C-179-XX-X
.285 7.24
REF
XX.XX
(SEE NOTE 11)
C
DWC-XX-10-300
C
XX.XX
(SEE NOTE 11)
FIG 1
"A"
MMSS-05-22-X-XX.XX-S SHOWN
SECTION "A"-"A"
FIG 2
MMSS-05-22-X-XX.XX-D-LUS SHOWN
UNLESS OTHERWISE SPECIFIED,
DIMENSIONS ARE IN INCHES.
TOLERANCES ARE:
DECIMALS
PROPRIETARY NOTE
THIS DOCUMENT CONTAINS INFORMATION
CONFIDENTIAL AND PROPRIETARY TO
SAMTEC, INC. AND SHALL NOT BE REPRODUCED
OR TRANSFERRED TO OTHER DOCUMENTS OR
DISCLOSED TO OTHERS OR USED FOR ANY
PURPOSE OTHER THAN THAT WHICH IT WAS
OBTAINED WITHOUT THE EXPRESSED WRITTEN
CONSENT OF SAMTEC, INC.
.XX: .01 [0.3]
2
.XXX: .005 [0.13]
.XXXX: .0020 [0.051]
ANGLES
520 PARK EAST BLVD, NEW ALBANY, IN 47150
PHONE: 812-944-6733
FAX: 812-948-5047
e-Mail info@SAMTEC.com
code 55322
DESCRIPTION:
DWG. NO.
MATERIAL:
DO NOT SCALE DRAWING
SHEET SCALE: 1.5:1
HOUSING: NYLON 6/6, COLOR: WHITE
CONTACT: PHOS BRONZE
CABLE; INSULATION: SEE CALLOUT
WIRE: TINNED COPPER
F:\DWG\MISC\MKTG\MMSSX-XX-XXX-X-XX.XX-X-X-XXX-MKT.SLDDRW
.100[2.54] SOCKET DISCREET CABLE ASSEMBLY
MMSSX-XX-XXX-X-XX.XX-X-X-XXX
BY:
DEAN P
05/03/2005
SHEET
1
OF
3
Capacitor discharge circuit problem
As shown in the figure, the half-bridge inverter topology In the case of power failure, if the ±Vbus bus voltage is greater than 36V, the drive signals of the two power tubes Q1 and Q2 still exist, ca...
shaorc Analog electronics
[Power Supply Q&A] + Closed-loop circuit issues of switching power supplies
Should the feedback loop of the buck switching power supply include the ferrite bead connected to the output terminal in the loop? What impact will it have if it is included? Generally, it should not ...
百万千万 Power technology
PSoC: Programmable System on Chip
[table=450] [tr][td=2,1]Cypress releases new high-performance, low-power PSoC3 and PSoC5 programmable system-on-chip architectures[i][2009.10.1][/i] [/td][/tr] [tr][td=2,1]Cypress Semiconductor has la...
makechinawei FPGA/CPLD
Has anyone ever debugged USB?
I recently looked at USB. I wonder if you have experience in learning USB. Can you share some tips? For example, what are the precautions and difficulties?...
daicheng Embedded System
Problems encountered when reading and writing ds1302 with msp430f149
I just started to use msp430 and don't understand many things. I hope experts can give me some advice on how to read and write ds1302 with msp430f149. The program is as follows: #include typedef unsig...
小菜小菜 Microcontroller MCU
Urgent, please tell me how to use ActiveX controls in smart device projects
As the title says, I have made an MFC ActiveX control. According to the information on the Internet, I have registered this control on the Windows Mobile simulator, but I cannot register it on the PC....
yangjie050322 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1611  370  2866  2329  198  33  8  58  47  4 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号