CFE400M12-5C-N1-CML-NT

Description
300W Convection / 400W Fan Cooled Medical Power Supplies
File Size379KB,2 Pages
ManufacturerTDK Corporation
Websitehttp://www.tdk.com
Download Datasheet View All

CFE400M12-5C-N1-CML-NT Overview

300W Convection / 400W Fan Cooled Medical Power Supplies

CFE400M Series
300W Convection / 400W Fan Cooled Medical Power Supplies
Features
u
Medical & ITE Safety Certifications (BF Rated)
u
94% Efficient
u
0.5W Standby Power
u
Meets ERP/Eco-Design (2009/125/EC)
u
Meets Climate Savers Gold Level
u
450W Peak Loading (10s)
u
High Power Density (7” x 4” x 1.6”)
u
Suitable for 1U applications
u
Five Year Warranty
Key Market Segments & Applications
Specifications
Model
Input Voltage range
Input Frequency
Inrush Current
Power Factor Harmonics
Voltage Setting Accuracy
Regulation
Ripple & Noise
Efficiency (230VAC, 80% load)
Overcurrent Protection
Overvoltage Protection
Overtemperature Protection
Hold Up Time (Typ)
Leakage Current (max)
Fan Supply
Standby Voltage
Remote Sense
Signals & Features
Operating Temperature
(1)
VAC
Hz
A
-
%
%
mV
%
-
V
-
ms
mA
-
-
-
-
°C
CFE400M
85 - 264VAC
47 - 63Hz, 440Hz with reduced PFC
<20A at 25°C and 230VAC input, Cold Start
EN61000-3-2 Compliant. Class A (Class C >100W output power)
±1% at 50% Load
Line: 0.25%; Load: 1%; Thermal Coefficient: 0.02%/°C
1% peak-peak
94% typical (48V & 24V), 91% (12V), 0.5W power draw in standby mode
Automatic recovery upon overload removal
Cycle AC line to reset
Yes
15ms at full load
140mA 120VAC 60Hz, 280mA 240VAC 60hz, <300mA 240VAC 63Hz (Type Test results)
12V 0.25A (Not available if the top fan option is selected)
5V 80mA or 5V 2A (chosen at time of ordering)
None
Remote on/off - Inhibit or Enable operation (chosen at time of ordering)
Power Good - High indicates DC output & AC input is good. ORing FET - (Option)
Convection cooled: 0 to +60°C. Derate linearly to 50% load from 40°C to 60°C
Forced air cooled: 0 to +70°C. Derate linearly to 50% load from 50°C to 70°C
-40 to +70°C
5 - 95%RH
Convection, internal fan or external 1.5m/s forced air , approx. 12 CFM (see oper. temp.)
Input to Ground 1500VAC, Input to Output 4kVAC (Reinforced), Output to Ground 1500VAC
2G, 10-500Hz in all 3 planes. MIL-STD-810E, Method 514.4, Pro I, Cat 1, 9
30G per IEC68-2-27, MIL-STD-810E/F, Method 516.5, Pro I, IV, VI
IEC/UL/EN/CSA22.2 60601-1, IEC/UL/EN 61010-1, IEC/UL/EN/CSA22.2 No 60950-1, CE for LVD
EN61000-4-2, -3, -4, -5, -6, -8, -11, -12, -14
EN55011, EN55022 Class B (per CISPR.11/22), EN61000-3-3
EN55011, EN55022 Class B (per CISPR.11/22)
U Channel: 0.71kg, Top fan: 0.86kg
U channel: 7 x 3.94 x 1.6, With cover: 7 x 3.94 x 2, Top Fan: 7 x 3.94 x 2.8
Five Years
Storage Temperature
°C
Humidity (non condensing)
%RH
Cooling
-
Isolation
-
Vibration (non operating)
-
Shock
-
Safety Agency Certifications (2)
-
Immunity
-
Conducted Emissions and Flicker
-
Radiated Emissions
-
Weight (open frame)
kg
Size
in
Warranty
yrs
(1) -20°C cold start
(2) Designed to meet IEC/EN/UL/CSA 61010-1 Edition 2
1-800-526-2324 • www.us.tdk-lambda.com/lp/
19
Disclaimer: us.tdk-lambda.com/lp/legal.htm
Wireless Module Selection Guide 433MHz 2.4G
Welcome to download. Very detailed. Application documentation. Some code....
xiazhaojian RF/Wirelessly
How to use pseudo IP to communicate with client TCP
----------- * Software environment: WinXP sp2 The Ndis5.0 driver for intercepting data packets has been written. At the user level, the IP address of the data packet sent by the driver can be modified...
sabrinatang Embedded System
ADC0809
I have a problem with how to write a program to collect voltage using ADC0809. Can anyone provide a complete reference program? By the way, can I use a function generator to provide 500khz clock? If I...
hzp08041234 DIY/Open Source Hardware
[Help] Can the SPI port and UART port of MSP430F169 be used at the same time?
As the title says, can SPI0 and USART0 be used at the same time? Can SPI1 and USART1 be used at the same time? On msp430f149, they cannot be used at the same time. Please give me some advice....
karise Microcontroller MCU
Balancing ADC Size, Power, Resolution, and Bandwidth for Precision Data Acquisition Systems
[i=s]This post was last edited by qwqwqw2088 on 2021-12-24 08:41[/i]The trend toward smaller industrial products is creating new challenges for precision data acquisition systems. Designers must balan...
qwqwqw2088 Analogue and Mixed Signal
Can ultrasound detect the net?
[i=s]This post was last edited by paulhyde on 2014-9-15 03:31[/i] I really don’t know if ultrasound can detect the grid around the four axes because I don’t have the materials. . . I read in the liter...
yangshichang110 Electronics Design Contest

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2825  1880  9  1242  1016  57  38  1  25  21 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号