EEWORLDEEWORLDEEWORLD

Part Number

Search

86010C-J-4HA

Description
MIL Series Connector, 56 Contact(s), Metal, Male, Crimp Terminal, Receptacle
CategoryThe connector    The connector   
File Size65KB,1 Pages
ManufacturerHiRel Connectors Inc
Websitehttps://hirelco.net
Download Datasheet Parametric View All

86010C-J-4HA Overview

MIL Series Connector, 56 Contact(s), Metal, Male, Crimp Terminal, Receptacle

86010C-J-4HA Parametric

Parameter NameAttribute value
MakerHiRel Connectors Inc
Reach Compliance Codeunknown
Other featuresSTANDARD: MIL-DTL-38999
Back shell typeSOLID
Body/casing typeRECEPTACLE
Connector typeMIL SERIES CONNECTOR
Contact to complete cooperationNOT SPECIFIED
Contact point genderMALE
Coupling typeTHREADED
DIN complianceNO
empty shellNO
Environmental characteristicsCORROSION RESISTANT; ENVIRONMENT RESISTANT; FLUID RESISTANT
Filter functionNO
IEC complianceNO
MIL complianceYES
Manufacturer's serial number86010
Plug informationMULTIPLE MATING PARTS AVAILABLE
Mixed contactsNO
Installation typeCABLE AND PANEL
OptionsGENERAL PURPOSE
Shell materialMETAL
Housing sizeJ
Termination typeCRIMP
Total number of contacts56
D38999/24
Jam Nut Mount Environment Resistant Receptacle
MIL-DTL-38999
Series III – Threaded Coupling
NOTES:
1. PANEL THICKNESS .126/.050 [3.20/1.58]
2. CONNECTOR CONTAINS REQUIRED FEATURES FOR
PROPER FIT IN A TYPE "E" PANEL
3. FOR CONNECTOR COMPONENTS AND ACCESSOROES,
SEE PAGE C-5
ØA
2 PLCS
1.279 [32.5]
MAX
.889 [22.6] MAX.
.519/.500 [13.2/12.7]
(FULLY MATED INDICATOR
BAND - RED)
S
P
SEE CONTACT
STYLE
DESIGNATOR
ON ORDERING
INFORMATION
PAGE
B Flat
BB Thd
G Thd
O-Ring
W
VV Thd
SHELL SHELL
SIZE
SIZE CODE
9
11
13
15
17
19
21
23
25
A
B
C
D
E
F
G
H
J
ØA
±.011
[±0.3]
1.189 [30.2]
1.374 [34.9]
1.500 [38.1]
B Flat BB Thd G Thd
CLASS 2A
+.004/-.006
[+0.10/-0.15] 0.1P-0.3L-TS
.651 [16.53]
.751 [19.07]
.938 [23.82]
.6250
.7500
.8750
1.0000
1.1875
1.2500
1.3750
1.5000
1.6250
M17 x 1.0
M20 x 1.0
M25 x 1.0
M28 x 1.0
*M32 x 1.0
M35 x 1.0
M38 x 1.0
M41 x 1.0
M44 x 1.0
P
S
±.016
[±0.4]
VV Thd
-6g 0.100R
M12 x 1.0
M15 x 1.0
M18 x 1.0
M22 x 1.0
M25 x 1.0
M28 x 1.0
M31 x 1.0
M34 x 1.0
M37 x 1.0
W
+.035/-.004
[+0.9/-0.1]
.087 [2.2]
.087 [2.2]
.087 [2.2]
.087 [2.2]
.087 [2.2]
.118 [3.0]
.118 [3.0]
.118 [3.0]
.118 [3.0]
-6g 0.100R +.024/-.000
[+0.6/-0.0]
.555 [14.1] 1.063 [27.0]
.555 [14.1] 1.252 [31.8]
.555 [14.1] 1.374 [34.9]
.555 [14.1] 1.500 [38.1]
.555 [14.1] 1.626 [41.3]
.555 [14.1] 1.811 [46.0]
.555 [14.1] 1.937 [49.2]
.555 [14.1] 2.063 [52.4]
.555 [14.1] 2.189 [55.6]
1.626 [41.3] 1.062 [26.97]
1.752 [44.5] 1.187 [30.15]
1.937 [49.2] 1.312 [33.32]
2.063 [52.4] 1.437 [36.50]
2.189 [55.6] 1.562 [39.67]
2.311 [58.7] 1.687 [42.85]
* = MODIFIED MAJOR DIA. 1.258/1.252 [31.95/31.80]
DIMENSIONS ARE IN INCHES [MILLIMETERS]
United States
– 760 W. Wharton Drive, Claremont CA. 91711
Ph: 909-626-1820
FAX: 909-399-0626
Web:
www.HIRELCO.com
Europe
– 5 Rue Des Longues Raies, Z.I. Des Garennes, 78440; Gargenville, France
Ph: 33(0) 1-309-38999 or U.K. 44(0)1-980-843887
FAX 33(0) 1-309-38913
Web:
www.HIRELCO.com
C-16
Microwave Transmission Technology and Application of Television Signals
[i=s]This post was last edited by jameswangsynnex on 2015-3-3 19:58[/i][Abstract]The microwave transmission technology of television signals is introduced, the characteristics of microwave transmissio...
JasonYoo Mobile and portable
Why does the data received by 430 from hx711 not change?
[font=宋体]It's just my program[/font] [font=宋体]The LCD only shows a fixed number and it doesn't change[/font] [font=宋体]I don't know why? [/font] [font=宋体]Is there anyone who knows how to do this? [/fon...
宇飞天 Electronics Design Contest
FPGA beginners getting started, please give me some advice
Let me talk about my own situation first: I just finished learning Verilog HDL by myself, downloaded ModelSim-Altera 6.4a, and can use it to do some simple simulations, and the test program is mainly ...
scm FPGA/CPLD
[Newbie Help] Routing nodes broadcast information to other routing nodes
If I have 1 coordinator and N routers, I hope that after networking, I can realize information exchange between N points, and any routing node broadcasts to other routing nodes. But I can't find simil...
a102308667 RF/Wirelessly
Electronic Transformer
[i=s]This post was last edited by paulhyde on 2014-9-15 09:21[/i] Electronic Transformer...
wuhanjikaifei Electronics Design Contest
Battery internal resistance measurement methods used in two industries
[size=14px] In industry applications, the precise measurement of battery internal resistance is carried out through special equipment. Let me talk about the battery internal resistance measurement met...
bjhyyq Power technology

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 974  2831  36  784  2098  20  57  1  16  43 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号