EEWORLDEEWORLDEEWORLD

Part Number

Search

5145-A026FC00U2-230

Description
Mains Power Connector, 2A, 125/250VAC, Male, ROHS COMPLIANT
CategoryThe connector    The connector   
File Size543KB,5 Pages
ManufacturerSCHURTER
Websitehttp://www.schurterinc.com/
Environmental Compliance  
Download Datasheet Parametric View All

5145-A026FC00U2-230 Overview

Mains Power Connector, 2A, 125/250VAC, Male, ROHS COMPLIANT

5145-A026FC00U2-230 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerSCHURTER
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
Other featuresSTANDARDS: IEC/EN 60320-1/C14; UL 94V-0; CSA; VDE, QUICK CONNECT
Connector typeMAINS POWER CONNECTOR
Contact to complete cooperationTIN/TIN COPPER
Contact completed and terminatedTIN/TIN COPPER
Contact point genderMALE
Contact materialNOT SPECIFIED
Coupling typeSNAP
DIN complianceNO
IEC complianceYES
JESD-609 codee3/e2
MIL complianceNO
Power Connector Ratings2A, 125/250VAC
Installation typePANEL
OptionsGENERAL PURPOSE
Shell materialPOLYETHYLENE
Total number of contacts3
5145
POWER ENTRY MODULES WITH LINE FILTER
Standard- or Medical-Filter
Inlet filter, front side mounting, circuit breaker TA45 2-pole
C14
70° C
Description
- Panel Mount:
Screw-on from front side
- 3 Functions:
Inlet Protection class I, circuit breaker type TA45 2-pole, Line filter in
standard and medical version
- Quick connect terminals 6.3 x 0.8 mm
- Alternative: version without line filter
6145
- We recommend for new applications type
DF12
Characteristics
- All single elements are already wired
Unwired versions available on request
- Line switch non-illuminated or illuminated
Thermal overload protection
Optional with undervoltage release or remote trip release
- Qualified for use in equipment according IEC/EN 60950
Weblinks
Approvals:
http://www.schurter.com/approvals
RoHS:
http://www.schurter.com/rohs
Approvals
- VDE License Number: 117118
- UL License Number: E72928
Technical Data
Ratings IEC
Ratings UL/CSA
Leakage Current
Dielectric Strength
1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz
1 - 15 A @ Ta 40 °C / 125 VAC; 60 Hz
standard < 0.5 mA (250 V / 60 Hz)
medical < 5 µA (250 V / 60 Hz)
> 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (2 sec)
-10 °C to 55 °C
10/055/21acc. to, IEC 60068-1
from front side IP 40 acc. to IEC 60529
Suitable for appliances with protection
class I acc. to IEC 61140
Quick connect terminals 6.3 x 0.8 mm
Screw-on: max 8 mm
Mounting screw torque max 0.5 Nm
Thermoplastic, black, UL 94V-0
Appliance-Inlet /-Outlet
C14 acc. to IEC/EN 60320-1,
UL 498, CSA C22.2 no. 42 (for cold con-
dition) pin-temperature 70 °C, 10 A, Pro-
tection class I
Acc. IEC/EN 60934, UL 1077, CSA 22.2
no. 235
2-pole rocker switch, illuminated or non-il-
luminated. Optional with undervoltage- or
remote trip release
Short circuit capacity Icn:
at In < 3A/240VAC : 10 x In
at In
3A/240VAC : 300A
acc. to IEC 61058-1
Technical details
Standard and Medical Version, IEC
60939, IEC 60601-1, UL 1283, UL 544,
EN 133 200, CSA C22.2 no. 8
Technical details
> 100'000 h acc. to MIL-HB-217 F
Circuit breaker
Allowable Operation Temp.
Climatic Category
Degree of Protection
Protection Class
Terminal
Panel Thickness s
Material: Housing
Line Switch
Line Filter
MTBF
1
www.schurter.com
Restart on VxWorks startup
I have a computer with Vxwork operating system. I copied the hard disk through ghost and then copied it to another computer. Why can't it start up? It reports an error and then restarts. The configura...
sf19840705 Real-time operating system RTOS
The electrician is crazy
A very good activity, support! !...
benghopy Discrete Device
Learning software proteus related information
Learning software proteus related information...
护花使者 FPGA/CPLD
KingView and the board (EVOC pcl818L) cannot communicate. How can I install the driver?
I have used the board EVOC pcl 818L and Kingview to develop. The system driver has been installed, but I don't know how to install the driver in Kingview? Please help! !...
酷联 Embedded System
TI Sitara AM335x system power supply uses TPS650250 to power AM335x
This document details the power solution for the AM335x application processor with the TPS650250 power management unit (PMU) or power management IC (PMIC). The following figure is a connection diagram...
IC爬虫 DSP and ARM Processors
The SPWM software subdivision stepper motor speed cannot be increased. Please discuss where the problem may be.
[i=s]This post was last edited by ethan0ly on 2014-10-27 23:07[/i] Hi everyone, I am a student, and I am currently working on stepper motor driver. I use the STM32 table lookup method to implement SPW...
ethan0ly stm32/stm8

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 768  1710  2342  1272  2630  16  35  48  26  53 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号