EEWORLDEEWORLDEEWORLD

Part Number

Search

MS90540-12

Description
General Purpose Inductor, 3300uH, 5%, 1 Element, Iron-Core
CategoryPassive components    inductor   
File Size2MB,2 Pages
ManufacturerGowanda Electronics
Download Datasheet Parametric View All

MS90540-12 Overview

General Purpose Inductor, 3300uH, 5%, 1 Element, Iron-Core

MS90540-12 Parametric

Parameter NameAttribute value
Is it Rohs certified?incompatible
MakerGowanda Electronics
Reach Compliance Codenot_compliant
ECCN codeEAR99
STANDARD RF INDUCTORS - THRU HOLE
19M, 22M, 24M
19MLF, 22MLF, 24MLF
*
TRADITIONAL
Pb
COMPLIANT
RoHS
Wirewound, Molded
PART
NUMBER
19M273J
19M303J
19M333J
19M363J
19M393J
19M433J
19M473J
19M513J
19M563J
19M623J
19M683J
19M753J
19M823J
19M913J
19M104J
22M114J
22M124J
22M134J
22M154J
22M164J
22M184J
22M204J
22M224J
22M244J
22M274J
22M304J
22M334J
22M364J
COTS
MIL SPEC
DESIGNATION
MS90539-01
MS90539-02
MS90539-03
MS90539-04
MS90539-05
MS90539-06
MS90539-07
MS90539-08
MS90539-09
MS90539-10
MS90539-11
MS90539-12
MS90539-13
MS90539-14
MS90539-15
MS90540-01
MS90540-02
MS90540-03
MS90540-04
MS90540-05
MS90540-06
MS90540-07
MS90540-08
MS90540-09
MS90540-10
MS90540-11
MS90540-12
MS90540-13
L
µH
270
300
330
360
390
430
470
510
560
620
680
750
820
910
1000
1100
1200
1300
1500
1600
1800
2000
2200
2400
2700
3000
3300
3600
Q
MIN
65
65
65
65
65
65
65
65
65
60
60
60
60
60
60
60
60
60
65
65
65
65
70
70
70
70
70
70
TEST FREQ
L&Q
MHz
0.79
0.79
0.79
0.79
0.79
0.79
0.79
0.79
0.79
0.79
0.79
0.79
0.79
0.79
0.79
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
SRF
MHz
MIN
5.6
5.3
5.0
4.7
4.5
4.3
4.0
3.8
3.6
3.5
3.4
3.3
3.1
2.9
2.8
2.8
2.7
2.6
2.4
2.3
2.2
2.1
2.0
1.9
1.8
1.7
1.6
1.5
DCR
OHMS
MAX
8.2
8.7
9.1
9.6
10.0
10.6
11.1
11.6
12.3
13.0
13.7
14.4
15.1
15.8
16.5
21.0
22.0
23.0
25.0
26.0
28.0
29.0
30.0
31.0
33.0
35.0
38.0
40.0
CURRENT
RATING
mA DC
110
107
105
102
100
97
95
93
91
88
85
83
81
79
78
78
76
75
72
70
68
67
66
64
62
61
58
57
MS90539 - POWDERED IRON CORE
MS90540 - POWDERED IRON CORE
Suffix “J” for 5% tolerance
Optional tolerances available; please contact factory
Custom designs are available to meet your specific requirements; please contact factory
*Add “LF” suffix for RoHS requirement. Example: 19M273JLF
Gowanda designates a component RoHS-compliant by adding “LF” (lead free) to the
part number. These LF components meet the ≤ .1% lead requirement and they are
compatible with 260°C soldering processes.
continued next page
NOTES:
• Operating Temperature Range:
-55°C to +105°C
• Current Rating is based on a 15°C temperature rise
at an ambient temperature of 90°C
• DWV 700 Vrms @ Sea Level
180 Vrms @ 70,000 Feet
• Laser marking is standard.
1.438 ± 0.188
(36.525 ± 4.77)
TAPE AND REEL SPECS - 19M Series:
Pcs./Reel maximum:
Pitch between parts:
Inside tape spacing:
Reel diameter
Class:
TAPE AND REEL SPECS - 22M Series:
Pcs./Reel maximum:
Pitch between parts:
Inside tape spacing:
Reel diameter
Class:
TAPE AND REEL SPECS - 24M Series:
Pcs./Reel maximum:
Pitch between parts:
Inside tape spacing:
Reel diameter
Class:
2000
0.200 in.
2.062 in.
12 in.
1
1000
0.400 in.
2.500 in.
12 in.
2
1000
0.400 in.
2.500 in.
12 in.
2
B
270µH
± 5%
SERIES
19
22
24
A
C
Color coded in accordance with MIL-C-15305.
Letter suffix on part number denotes tolerance.
Other tolerances available.
in. (mm)
A ± 0.010
0.190
0.215
0.240
B ± 0.010
0.440
0.560
0.740
C
22 AWG
22 AWG
20 AWG
One Magnetics Pkwy, Gowanda, NY 14070 • (t) 716-532-2234 • (f) 716-532-2702 • sales@gowanda.com
www.gowanda.com
122113
Ultrasonic receiving
Excuse me: Why is the ultrasonic receiver configured as floating? ? And not configured as other inputs? ?...
18166 stm32/stm8
Problems with DSPIC's SPI port
The SPI port only sends numbers. When can we determine that it has been sent?...
axlylee Embedded System
I don't understand the fuel tank oil level detection circuit, need some advice.
The picture shows a fuel tank oil level detection circuit on an anti-theft device (the oil float is a resistive oil level sensor), but I really don’t understand the intention of the circuit part surro...
shiyi_jiang Integrated technical exchanges
Several Issues on Lead-Lag Digital PLL
1. How is the phase detector implemented? 2. How is the filter circuit implemented?...
eeleader FPGA/CPLD
About INF files and driver loading issues
I prepared an inf file for the device (generated by windriver). However, in XP, when the device is plugged in, only the hardware wizard pops up and the driver needs to be installed manually. Why can't...
yuhongcai11 Embedded System
[Motor Kit P-NUCLEO-IHM] Check-in for Part 5, Task 2
[i=s] This post was last edited by Changjianze1 on 2018-6-21 08:45 [/i] [size=6] Check-in for the fifth task 2 [/size] Task 2: Get the key variables during FOC control: Ia, Ib, Ic, Ialpha, Ibeta, Id, ...
常见泽1 stm32/stm8

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1878  2033  2923  61  314  38  41  59  2  7 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号