5 Energy Way, P.O. Box 1019, West Warwick, RI 02893 USA Tel. 800-424-9850 / 401-823-5200 Fax 401-823-8723 Email advintcorp@aol.com Internet http://www.advintcorp.com
.100" (2.54 mm) Pitch Board to Board Interconnections
NB/LNB - Single Row
Molded Female
DRS - Dual Row
Molded Female
NA - Single Row
Molded Male
DRA - Dual Row
Molded Male
KSS - Single Row
Peel-A-Way
®
Female
DKS - Dual Row
Peel-A-Way
®
Female
NEW PHOTO
Low Profile
Board to Board
KSA - Single Row
Peel-A-Way
®
Male
DKA - Dual Row
Peel-A-Way
®
Male
Features:
!
High reliability method of
interconnecting.
!
Reliable mechanical support.
!
Complete flexibility. If the board to
board spacing you need is not shown
on pages 54 - 55 , consult factory.
Terminals and Contacts:
Terminal: Brass - Copper Alloy 360,
ASTM-B-16
Contact: Beryllium Copper - Copper
Alloy 172, ASTM-B-194
Plating:
Terminal: Gold over Nickel or
Tin-Lead over Nickel
Contact: Gold over Nickel or
Tin-Lead over Nickel
Body Material:
Molded -
Glass filled thermoplastic
Polyester (P
.B.T.) U.L. Rated 94V-O,
-60
°
C to 140
°
C (-76
°
F to 284
°
F)
High Temp Molded
- High temp. glass
filled thermoplastic, U.L. Rated 94V-O,
-60
°
C to 260
°
C (-76
°
F to 500
°
F)
Peel-A-Way
®
- Polyimide Film - Temp.
range -269
°
C to 400
°
C(-452
°
F to 752
°
F)
Page 52
How To Order
Single and Dual RowFemale
NB
010
-01
T
G
Contact Plating
G - Gold
T - Tin-Lead
Terminal Plating
G - Gold
T - Tin-Lead
Terminal Type
See page 53 for available
terminal types.
Body Type
NB/LNB - Single Row Molded
HNB/HLNB - Single Row High Temp Molded
KSS - Single Row Peel-A-Way
®
DRS - Dual Row Molded
HDRS - Dual Row High Temp Molded
DKS - Dual Row Peel-A-Way
®
Number of Pins
NB/LNB - 3 - 32, KSS - 2 - 100
DRS - 20 - 70, DKS - 4 - 200
How To Order
Single and Dual Row Male
NA
Body Type
NA - Single Row Molded
HNA - Single Row High Temp Molded
KSA - Single Row Peel-A-Way
®
DRA - Dual Row Molded
HDRA - Dual Row High Temp Molded
DKA - Dual Row Peel-A-Way
®
010
-68
T
Terminal Plating
G - Gold
T - Tin-Lead
Terminal Type
See page 53 for available
terminal types.
Number of Pins
NA/HNA - 3 - 32, KSA - 2 - 100
DRA/HDRA - 20 - 70, DKA - 4 - 200
Peel-A-Way® covered by patent rights issued and or pending.
inch/(mm)
Quick turn delivery available on standard terminal types.
.
5 Energy Way, P.O. Box 1019, West Warwick, RI 02893 USA Tel. 800-424-9850 / 401-823-5200 •Fax 401-823-8723 •Email advintcorp@aol.com •Internet http://www.advintcorp.com
®
®
ADVANCED
Board to Board Interconnections
INTERCONNECTIONS
.100" (2.54 mm) Pitch Board to Board Interconnections
Male Terminal Information
Peel-A-Way® Only
.072 Dia.
(1.83)
.125
(3.18)
.070
(2.16)
.030
(.76)
.125
(3.18)
.125
(3.18)
.018 Dia.
(.46) Typ. 2
.018 Dia.
(.46) Typ. 2
Type -79
Peel-A-Way® Only
.072 Dia.
(1.83)
.125
(3.18)
Type -80
Peel-A-Way® Only
.072 Dia.
(1.83)
.125
(3.18)
.085
(2.16)
.125
(3.18)
Type -81
Type -444
.018 Dia.
(.46)
.125
(3.18)
.052
(1.32)
.103
(2.62)
.125
(3.18)
.018 Dia.
(.46)
.018 Dia.
(.46) Typ. 2
Type -68
.018 Dia.
(.46)
.125
(3.18)
.100
(2.54)
Type -43
.018 Dia.
(.46)
.125
(3.18)
Type -399
.018 Dia.
(.46)
.125
(3.18)
Type -185
.018 Dia.
(.46)
.125
(3.18)
.210
(5.33)
.335
(8.51)
.100
(2.54)
.100
(2.54)
.379
(9.63)
.100
(2.54)
.500
(12.70)
Board to Board
.125
(3.18)
.018 Dia.
(.46)
.018 Dia.
(.46)
.125
(3.18)
.018 Dia.
(.46)
.125
(3.18)
.018 Dia.
(.46)
.125
(3.18)
Type -42
.018 Dia.
(.46)
.125
(3.18)
Type -398
.018 Dia.
(.46)
.125
(3.18)
Type -403
.018 Dia.
(.46)
.125
(3.18)
Type -71
.018 Dia.
(.46)
.125
(3.18)
.585
(14.86)
.100
(2.54)
.100
(2.54)
.679
(17.25)
.100
(2.54)
.750
(19.06)
.100
(2.54)
.835
(21.21)
.018 Dia.
(.46)
.125
(3.18)
.018 Dia.
(.46)
.125
(3.18)
.018 Dia.
(.46)
.125
(3.18)
.018 Dia.
(.46)
.125
(3.18)
Female Terminal Information
Peel-A-Way® Only
.058 Dia.
(1.47)
Type -210
Peel-A-Way® Only
.058 Dia.
(1.47)
Type -85
Type -299*
.050(1.27) Molded Insulator Thickness
.072 Dia.
(1.83)
Type -49*
.072 Dia.
(1.83)
.015
(.38)
.083
(2.11)
.155
(3.94)
.031
(.79)
.095
(2.41)
.155
(3.94)
.082
(2.08)
.095
(2.41)
.028 Dia.
(.71)
.034 Dia.
(.86)
.038 Dia.
(.97)
.025 Dia.
(.64)
Type -04*
.072 Dia.
(1.83)
Type -51*
.072 Dia.
(1.83)
Type -01
Molded Body Only
.072 Dia.
(1.83)
Peel-A-Way® Only
.072 Dia.
(1.83)
Type -33
.120
(3.05)
.130
(3.30)
.165
(4.19)
.165
(4.19)
.110
(2.79)
.028 Dia.
(.71)
.020 Dia.
(.51)
.110
(2.79)
.125
(3.18)
.020 Dia.
(.51)
.125
(3.18)
.020 Dia.
(.51)
inch/(mm)
* These terminal types are available in either molded or Peel-A-Way®.
Peel-A-Way® covered by patent rights issued and or pending.
Today we disassembled the car computer of Toyota RAV4, which is an older model. It can be bought on a certain fish website for about 100 yuan. In the past, some netizens would modify it to use as a so...
In the 220V AC protection circuit, the choice of fuse only needs to be lower than its rated voltage; do we not need to consider the peak voltage here? I remember that when selecting a varistor, we als...
Some time ago, especially when I was working on C2000, I also shed some sweat and posted some original posts, and found that they were reprinted on many websites. I am also pleased that my experience ...
Nonlinear Control Systems : https://training.eeworld.com.cn/course/5484The basics of nonlinear dynamic systems
Stability of nonlinear systems
Controller designs for nonlinear systems...
On August 24th, Jin Yuzhi, CEO of Huawei's Intelligent Automotive Solutions BU, announced the first automotive application of Huawei Qiankun's unique Limera technology. This technology eliminates t...[Details]
Some time ago, I attended the 4th Energy Chemistry Forum of the Chinese Chemical Society and learned about high-energy-density and high-safety batteries. I would like to summarize and share this wi...[Details]
Amidst the wave of intelligent automotive transformation, advanced driver assistance is gradually emerging from cutting-edge technology into the mainstream, becoming a new frontier of industry comp...[Details]
Common Mode Semiconductor has officially released its latest generation of power management ICs—the GM6506 series. This fully integrated high-frequency synchronous rectification step-down p...[Details]
With the rapid development of electric vehicles in my country, people are beginning to pay attention to the issue of radiation from electric vehicles. We all know that mobile phones emit radiation,...[Details]
Electric vehicles are becoming increasingly popular, with increasingly longer ranges. There are two ways to charge electric vehicles: slow charging and fast charging. Which is the most suitable? Sl...[Details]
Charging is a familiar process for new energy vehicles, and as a source of battery energy, charging piles are crucial. New energy vehicle charging can be divided into fast charging and slow chargin...[Details]
Coal mines typically contain gas and coal dust. When gas and coal dust reach a certain concentration, they can cause explosions. Electrical equipment generates arcs during normal operation or durin...[Details]
During daily operation of an R-type power transformer, the voltage used varies as the equipment being used adjusts. This raises the question: can the transformer change voltage at this point? The a...[Details]
Bosch has released a new SoC series to support L2+ advanced driver assistance functions. The chip integrates high resolution and long-range detection capabilities, and has built-in support for neur...[Details]
Consumer demand for premium listening experiences has driven rapid evolution in the wireless headphone market in recent years. Hybrid designs, which utilize two drivers per earbud to enhance sound ...[Details]
introduction
In today's busy society, people experience chronic high stress, which in turn poses a significant threat to our health. Therefore, effectively relieving stress has become a pr...[Details]
Cadence and NVIDIA Collaborate to Revolutionize Power Analysis Technology, Accelerating Development of Billion-Gate AI Designs
Cadence's new Palladium Dynamic Power Analysis applicat...[Details]
With the development of vehicle technology, there are more types of cars. Cars are divided into hybrid, pure electric vehicles, and fuel vehicles. For hybrid cars, they are divided into plug-in hyb...[Details]
The basic structure of the power grid dispatching automation system includes three parts: control center, master station system, plant terminal (RTU) and information channel. According to the diffe...[Details]