EEWORLDEEWORLDEEWORLD

Part Number

Search

5145.ABTWF130C0.831

Description
Mains Power Connector, 15A, 125/250VAC, Male,
CategoryThe connector    The connector   
File Size524KB,4 Pages
ManufacturerSCHURTER
Websitehttp://www.schurterinc.com/
Download Datasheet Parametric View All

5145.ABTWF130C0.831 Overview

Mains Power Connector, 15A, 125/250VAC, Male,

5145.ABTWF130C0.831 Parametric

Parameter NameAttribute value
MakerSCHURTER
Reach Compliance Codecompliant
ECCN codeEAR99
Other featuresSTANDARDS: IEC/EN 60950; UL 94V-0; CSA; VDE, QUICK CONNECT
Connector typeMAINS POWER CONNECTOR
Contact to complete cooperationTIN COPPER
Contact completed and terminatedTIN
Contact point genderMALE
Coupling typeSNAP
DIN complianceNO
IEC complianceYES
JESD-609 codee3
MIL complianceNO
Power Connector Ratings15A, 125/250VAC
Installation typePANEL
OptionsGENERAL PURPOSE
Shell materialPOLYETHYLENE
Total number of contacts3
POWER ENTRY MODULES /
GERÄTESTECKER-KOMBIELEMENTE
Power entry module Type 5145
– Panel mount: screw-on version, front-side
– Appliance inlet, circuit breaker type TA 45 and line filter
5145
Standard or
Medical filter
50
75
100
Characteristics
• Circuit breaker with line switch, 2-pole, non-illuminated or
illuminated
• Combined with thermal overload protection
• Optional with undervoltage- or remote trip release
• All single elements wired
Unwired versions available on request
Technical data
Rated voltage
Rated currents I
n1
)
125/250 VAC; 50/60 Hz
1–10 A; @T
a
40 °C; SEV, VDE, Semko
1–15 A; @T
a
40 °C; UL, CSA
0,1–10 A; VDE, see table 1
0,1–15 A; UL/CSA, see table 1
< 0,5 mA (250 V/60 Hz)
< 5 µA (250 V/60 Hz)
1,7 kVDC between L-N
2,7 kVDC between L/N-PE
–10 °C to +55 °C
10/055/21 acc. to IEC/EN 60068-1
IP 40 acc. to IEC 60529
suitable for equipment with prot. cl. I,
acc. to IEC 61140
quick-connect 6,3 x 0,8 mm
max. 8 mm
Thermoplastic, black, UL94 V–0
Filter
TA 45
Leackage current, Standard
Medical
Test voltage (2 sec)
Allowable ambient air
temperatures T
a
Climatic category
Degree of protection (front-side)
Protection class
Terminals
Panel thickness s
Materials: Housing
Appliance-inlet
acc. to. IEC/EN 60320-1/C14,
Protection class I, pin-temperature 70 °C
(cold condition)
Circuit breaker
acc. to IEC/EN 60934, UL 1077,
type TA45
CSA 22.2 no. 235.
2-pole rocker switch, illuminated or
non-illuminated.
Optional with undervoltage- or remote
trip release
Short circuit capacity Icn:
at In < 3 A / 240 VAC: 10 x In
at In
3 A / 240 VAC: 300 A
Line filter, standard and medical acc. to. IEC 60939, EN 133 200,
UL 1283, CSA C 22.2 no. 8
Technical details see page 202
Application note
The rated current of the line filter must be equal or higher than the
rated current of the circuit-breaker.
1)
126
www.schurter.com
Design of intelligent charging lighting control system based on MSP430 single chip microcomputer
At present, energy shortage has become an important factor restricting social and economic development. How to achieve efficient use of energy is an important issue we face. As a new type of green lig...
fish001 Microcontroller MCU
Is there anyone who has done Question H?
[i=s]This post was last edited by paulhyde on 2014-9-15 09:38[/i] Help...
wangxiatiger Electronics Design Contest
Origin of Switching Power Supply Interest Group
The switching power supply interest group has started activities.  This group adopts the method that each member reads the designated books and considers several thinking questions within a certain pe...
maychang Switching Power Supply Study Group
How to obtain the license for the osxMotion library for your own project [Solved]
[i=s]This post was last edited by cocoasuny on 2016-12-13 13:36[/i] Does the library license provided by osxMotion support the license applied for by the official board? The license is node-locked to ...
cocoasuny ST Sensors & Low Power Wireless Technology Forum
IPTV Operation Conflict
[i=s]This post was last edited by jameswangsynnex on 2015-3-3 19:59[/i]IPTV third-party operation reduces conflicts between radio, television and telecommunications 2006-8-1Internet transformation is ...
hkn Mobile and portable
Temperature problems solved for you (VI) Fluid temperature monitoring
In previous articles, we have introduced the basic principles of temperature sensors. For many metering and industrial processes, it is necessary to directly measure the temperature of the fluid, or u...
EEWORLD社区 TI Technology Forum

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 389  562  1928  2019  2416  8  12  39  41  49 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号