220W Single Output Battery Charger
GC220
2 stage charging characteristic
Universal AC input / Full range
Built-in active PFC function, PF>0.90
No load power consumption<1W
3 pole AC inlet IEC320-C14
Class
I
power ( with earth pin)
series
■
Features :
Charger for lead-acid batteries (flooded,Gel
and AGM) and Li-ion
batteries (lithium iron and lithium manganese) (Note.1)
Protections: Short circuit / Overload / Over voltage / Over temperature
Cooling
by free air convection
Fully enclosed plastic case
2 color LED indicator for charging status
Approvals: UL / TUV / EAC / CB / FCC / CE
2 years warranty
( for GC220Axx-AD1 only)
ORDER NO.
GC220Axx-R7B (standard model)
GC220Axx-AD1 (optional model)
GC220Axx-
xx=12,24,48 ;
=R7B,AD1
GC220A12-
SAFETY MODEL NO.
DC VOLTAGE (Typ.)
GC220A12
13.6V
OUTPUT CONNECTOR
4pin power din
Anderson connector
SAFETY
TUV / CB / FCC / CE
/ EAC
UL / TUV / CB / FCC / CE
/ EAC
SPECIFICATION
ORDER NO.
GC220A24-
GC220A24
27.2V
40 ~ 125Ah
8A
217.6W
GC220A48-
GC220A48
54.4V
20 ~ 65Ah
4A
217.6W
OUTPUT
RECOMMENDED BATTERY
80 ~ 200Ah
Note.3
CAPACITY
CONTINUOS OUTPUT
CURRENT (Typ.)
RATED POWER
LED INDICATOR
VOLTAGE RANGE
FREQUENCY RANGE
POWER FACTOR (Typ.)
13.5A
183.6W
Note.4
90 ~ 264VAC
Charging(CC) : RED
Floating charging(CV) : GREEN
127 ~ 370VDC
PF>0.98 / 115VAC at full load
92.5%
2A / 230VAC
93%
47 ~ 63Hz
PF>0.90 / 230VAC
89%
4A / 115VAC
120A / 230VAC
1.5mA / 240VAC
90 ~ 110% rated output power
Protection type : Constant current limiting recovers automatically after fault condition is removed
Protection type :
Hiccup mode, recovers automatically after fault condition is removed
105 ~ 135% rated output voltage
Protection type :
Shut down o/p voltage, re-power on to recover
95
℃±
10
℃
(TSW1) detect on heatsink of power transistor
Protection type :
Shut down o/p voltage, recovers automatically after temperature goes down
-30 ~ +60
℃
(Refer to "Derating Curve")
20% ~ 90% RH non-condensing
-40 ~ +85
℃
, 10 ~ 95% RH
±
0.03% /
℃
(0~50
℃
)
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL1012 (for GC220Axx-AD1 only), TUV EN60950-1
,
EAC TP TC 004
approved
I/P-O/P: 3KVAC
I/P-O/P:100M Ohms / 500VDC / 25
℃
/ 70% RH
Compliance to EN55032 class B, EN61000-3-2,3, FCC PART 15 / CISPR22 class B, CAN ICES-3(B)-NMB-(B), EAC TP TC 020
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A, EAC TP TC 020
190Khrs min. MIL-HDBK-217F(25
℃
)
210*85*46mm (L*W*H)
1.1Kg; 12pcs/14.2Kg/0.73CUFT(GC220Axx-R7B)
1.2Kg; 12pcs/15.4Kg/1CUFT(GC220Axx-AD1)
See page 2 ; Other type available by customer requested
See page 2 ; Other type available by customer requested
INPUT
EFFICIENCY (Typ.)
AC CURRENT
INRUSH CURRENT (max.)
LEAKAGE CURRENT(max.)
OVERLOAD
SHORT CIRCUIT
Note.5
PROTECTION
OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
SAFETY &
ISOLATION RESISTANCE
EMC
(Note. 6)
EMC EMISSION
EMC IMMUNITY
OTHERS
CONNECTOR
NOTE
MTBF
DIMENSION
PACKING
PLUG
CABLE
1. Modification for charger specification may be required for different battery specification
.
Please contact battery vendor and MEAN WELL for details
.
2. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25
℃
of ambient temperature.
3. This is MeanWell's suggested range, please consult your battery manufacturer for their suggestions about maximum charging current limitation.
4. Derating may be needed under low input voltage. Please check the derating curve for more details.
5. Constant current operation region is within 50~100% rated output voltage.
6. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that whole system complies with the EMC directives.
7. The ambient temperature derating of 3.5
℃
/1000m with fanless models and of 5
℃
/1000m with fan models for operating altitude higher than 2000m(6500ft).
File Name:GC220-SPEC 2018-01-12