HLP-80H
series
Universal AC input / Full range (up to 305VAC)
Built-in active PFC function
Protections: Short circuit / Over current / Over voltage / Over temperature
Cooling by free air convection
Output constant current level adjustable
Class 2 power unit
Three in one dimming function (1~10Vdc or PWM signal or resistance)
Suitable for built in LED lighting system
Suitable for dry / damp locations
100% full load burn-in test
3 years warranty
SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
RATED POWER
VOLTAGE ADJ. RANGE
CURRENT ADJ. RANGE
12V
5A
60W
15V
9 ~ 15V
5A
75W
M
M
SELV
Bauar t gepruft
Sicherheit
egel ma ge
od
o s
be wac
g
S&E
( for 48V,54V only) ( except for 48V,54V )
www. tuv.com
ID 2000000000
HLP-80H-12 HLP-80H-15 HLP-80H-20 HLP-80H-24 HLP-80H-30 HLP-80H-36 HLP-80H-42 HLP-80H-48 HLP-80H-54
20V
12 ~ 20V
4A
80W
150mVp-p
17 ~ 22V
3.2 ~ 4A
±1.0%
±0.5%
±1.0%
24V
14.4 ~ 24V
3.4A
81.6W
150mVp-p
22 ~ 27V
2.72 ~ 3.4A
±1.0%
±0.5%
±0.5%
30V
18 ~ 30V
2.7A
81W
200mVp-p
27 ~ 33V
2.16 ~ 2.7A
±1.0%
±0.5%
±0.5%
36V
21.6 ~ 36V
2.3A
82.8W
200mVp-p
33 ~ 40V
1.84 ~ 2.3A
±1.0%
±0.5%
±0.5%
42V
25.2 ~ 42V
1.95A
81.9W
200mVp-p
38 ~ 46V
48V
28.8 ~ 48V
1.7A
81.6W
200mVp-p
43 ~ 53V
54V
32.4 ~ 54V
1.5A
81W
200mVp-p
49 ~ 58V
1.2 ~ 1.5A
±1.0%
±0.5%
±0.5%
CONSTANT CURRENT REGION
Note.4
7.2 ~12V
RIPPLE & NOISE (max.)
Note.2
150mVp-p
OUTPUT
150mVp-p
10.8 ~ 13.5V 13.5 ~ 17V
4 ~ 5A
±0.5%
4 ~ 5A
±2.0%
±0.5%
Can be adjusted by internal potentiometer
1.56 ~ 1.95A 1.36 ~ 1.7A
±1.0%
±1.0%
±0.5%
±0.5%
±0.5%
±0.5%
VOLTAGE TOLERANCE
Note.3
±2.5%
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
POWER FACTOR (Typ.)
TOTAL HARMONIC DISTORTION
INPUT
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT(Typ.)
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
LEAKAGE CURRENT
OVER CURRENT
SHORT CIRCUIT
Note.4
±1.5%
±2.0%
Note.6
1200ms,200ms/115VAC
16ms at full load
Note.5
90 ~ 305VAC
500ms,200ms/230VAC at 95% load
230VAC /115VAC
127 ~ 431VDC
47 ~ 63Hz
PF>0.96/115VAC, PF>0.96/230VAC, PF>0.94/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
THD< 20% when output loading
60% at 115VAC/230VAC input and output loading
75% at 277VAC input
89.5%
90%
88.5%
90%
0.85A / 115VAC
0.425A / 230VAC
0.4A / 277VAC
COLD START 70A(twidth=525
μ
s measured at 50% Ipeak) at 230VAC
87.5%
90%
90%
90%
90%
3 units (circuit breaker of type B) / 5 units (circuit breaker of type C) at 230VAC
<0.75mA / 277VAC
95 ~ 108%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Hiccup mode, recovers automatically after fault condition is removed
48 ~ 58V
35 ~ 43V
18 ~ 24V
28 ~ 35V
41 ~ 49V
14 ~ 17V
23 ~ 30V
Protection type : Shut down o/p voltage, re-power on to recover
Shut down o/p voltage, re-power on to recover
-40 ~ +70
(Refer to "Derating Curve")
20 ~ 95% RH non-condensing
-40 ~ +80
, 10 ~ 95% RH
±
0.03%/
(0 ~ 50
)
10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes
UL8750, CSA C22.2 No. 250.0-08 (except for 48V, 54V), EN61347-1, EN61347-2-13, GB19510.14 , GB19510.1,
EAC TP TC 004 approved ; Design refer to UL60950-1, TUV EN60950-1
I/P-O/P:3.75KVAC
I/P-FG:2KVAC
O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25
/ 70% RH
Compliance to EN55015, GB17743, GB17625.1, EN61000-3-2 Class C (
60% load, 12V model
65% load) ; EN61000-3-3, EAC TP TC 020
PROTECTION
OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP.
54 ~ 63V
59 ~ 68V
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
SAFETY & WITHSTAND VOLTAGE
EMC
ISOLATION RESISTANCE
EMC EMISSION
EMC IMMUNITY
OTHERS
NOTE
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level (surge 4KV), criteria B, EAC TP TC 020
MTBF
316.2Khrs min. MIL-HDBK-217F (25
)
167*53*29.5mm (L*W*H)
DIMENSION
0.27Kg; 36pcs/11.2Kg/0.67CUFT
PACKING
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25
of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Please refer to "DRIVING METHODS OF LED MODULE".
5. Derating may be needed under low input voltages. Please check the static characteristics for more details.
6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on
a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to
perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com)
8. Heat Sink HS1,HS2 can not be shorted.
9. Direct connecting to LEDs is suggested, but is not suitable for using additional drivers.
10. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently
connected to the mains.
File Name:HLP-80H-SPEC 2018-01-09

HLP-80H_12 Related Products

HLP-80H_12 HLP-80H-12 HLP-80H-15 HLP-80H-24 HLP-80H-36 HLP-80H-48 HLP-80H-54
Description 80W Single Output Switching Power Supply 80W Single Output Switching Power Supply 80W Single Output Switching Power Supply 80W Single Output Switching Power Supply 80W Single Output Switching Power Supply 80W Single Output Switching Power Supply 80W Single Output Switching Power Supply
Problems with simulating stm32 using proteus8.6
This problem occurs when using proteus8.6 to simulate stm32. How to solve it? Thank you!...
linjs123 stm32/stm8
National Semiconductor Launches LVDS Buffer with Low Signal Jitter and High ESD Protection
[i=s]This post was last edited by jameswangsynnex on 2015-3-3 20:00[/i]National Semiconductor Launches LVDS Buffer with Low Signal Jitter and High ESD ProtectionNational Semiconductor's LVDS transmitt...
hkn Mobile and portable
Problems in using C51 counter
I am learning about microcontrollers recently. I wrote a small program for a microcontroller counter in C. It is as follows: #includesbit P1_1=P1^1; void main() { TMOD=0x05; P1_1=1; while(1) { TR0=1; ...
afobbi Embedded System
Can the STM32 RTC replace the dedicated RTC chip?
Like the general clock chip 4543 (with external power supply) and DS12887 (with independent power supply), there is internal power-off protection and can output in the format of year, month, day, and ...
s21118666 stm32/stm8
Please help, I need the USB to serial port code under Wince 6.0
I want to implement USB to serial port conversion under WINCE 5.0. I saw on the Internet that WINCE 6.0 has already implemented this function, so please help me if you have installed WINCE 6.0. Send m...
zhangheng Embedded System
EEWORLD University ---- 2015 TI MCU Day (3) C2000
2015 TI MCU Day (3) C2000:https://training.eeworld.com.cn/course/2250...
hi5 Talking

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 735  2901  493  205  2544  15  59  10  5  52 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号