80W Single Output Switching Power Supply
■
Features :
HLP-80H
series
Universal AC input / Full range (up to 305VAC)
Built-in active PFC function
Protections: Short circuit / Over current / Over voltage / Over temperature
Cooling by free air convection
Output constant current level adjustable
Class 2 power unit
Three in one dimming function (1~10Vdc or PWM signal or resistance)
Suitable for built in LED lighting system
Suitable for dry / damp locations
100% full load burn-in test
3 years warranty
SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
RATED POWER
VOLTAGE ADJ. RANGE
CURRENT ADJ. RANGE
12V
5A
60W
15V
9 ~ 15V
5A
75W
M
M
SELV
Bauar t gepruft
Sicherheit
egel ma ge
od
o s
be wac
g
S&E
( for 48V,54V only) ( except for 48V,54V )
www. tuv.com
ID 2000000000
HLP-80H-12 HLP-80H-15 HLP-80H-20 HLP-80H-24 HLP-80H-30 HLP-80H-36 HLP-80H-42 HLP-80H-48 HLP-80H-54
20V
12 ~ 20V
4A
80W
150mVp-p
17 ~ 22V
3.2 ~ 4A
±1.0%
±0.5%
±1.0%
24V
14.4 ~ 24V
3.4A
81.6W
150mVp-p
22 ~ 27V
2.72 ~ 3.4A
±1.0%
±0.5%
±0.5%
30V
18 ~ 30V
2.7A
81W
200mVp-p
27 ~ 33V
2.16 ~ 2.7A
±1.0%
±0.5%
±0.5%
36V
21.6 ~ 36V
2.3A
82.8W
200mVp-p
33 ~ 40V
1.84 ~ 2.3A
±1.0%
±0.5%
±0.5%
42V
25.2 ~ 42V
1.95A
81.9W
200mVp-p
38 ~ 46V
48V
28.8 ~ 48V
1.7A
81.6W
200mVp-p
43 ~ 53V
54V
32.4 ~ 54V
1.5A
81W
200mVp-p
49 ~ 58V
1.2 ~ 1.5A
±1.0%
±0.5%
±0.5%
CONSTANT CURRENT REGION
Note.4
7.2 ~12V
RIPPLE & NOISE (max.)
Note.2
150mVp-p
OUTPUT
150mVp-p
10.8 ~ 13.5V 13.5 ~ 17V
4 ~ 5A
±0.5%
4 ~ 5A
±2.0%
±0.5%
Can be adjusted by internal potentiometer
1.56 ~ 1.95A 1.36 ~ 1.7A
±1.0%
±1.0%
±0.5%
±0.5%
±0.5%
±0.5%
VOLTAGE TOLERANCE
Note.3
±2.5%
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
POWER FACTOR (Typ.)
TOTAL HARMONIC DISTORTION
INPUT
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT(Typ.)
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
LEAKAGE CURRENT
OVER CURRENT
SHORT CIRCUIT
Note.4
±1.5%
±2.0%
Note.6
1200ms,200ms/115VAC
16ms at full load
Note.5
90 ~ 305VAC
500ms,200ms/230VAC at 95% load
230VAC /115VAC
127 ~ 431VDC
47 ~ 63Hz
PF>0.96/115VAC, PF>0.96/230VAC, PF>0.94/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
THD< 20% when output loading
≧
60% at 115VAC/230VAC input and output loading
≧
75% at 277VAC input
89.5%
90%
88.5%
90%
0.85A / 115VAC
0.425A / 230VAC
0.4A / 277VAC
COLD START 70A(twidth=525
μ
s measured at 50% Ipeak) at 230VAC
87.5%
90%
90%
90%
90%
3 units (circuit breaker of type B) / 5 units (circuit breaker of type C) at 230VAC
<0.75mA / 277VAC
95 ~ 108%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Hiccup mode, recovers automatically after fault condition is removed
48 ~ 58V
35 ~ 43V
18 ~ 24V
28 ~ 35V
41 ~ 49V
14 ~ 17V
23 ~ 30V
Protection type : Shut down o/p voltage, re-power on to recover
Shut down o/p voltage, re-power on to recover
-40 ~ +70
℃
(Refer to "Derating Curve")
20 ~ 95% RH non-condensing
-40 ~ +80
℃
, 10 ~ 95% RH
±
0.03%/
℃
(0 ~ 50
℃
)
10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes
UL8750, CSA C22.2 No. 250.0-08 (except for 48V, 54V), EN61347-1, EN61347-2-13, GB19510.14 , GB19510.1,
EAC TP TC 004 approved ; Design refer to UL60950-1, TUV EN60950-1
I/P-O/P:3.75KVAC
I/P-FG:2KVAC
O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25
℃
/ 70% RH
Compliance to EN55015, GB17743, GB17625.1, EN61000-3-2 Class C (
≧
60% load, 12V model
≧
65% load) ; EN61000-3-3, EAC TP TC 020
PROTECTION
OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP.
54 ~ 63V
59 ~ 68V
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
SAFETY & WITHSTAND VOLTAGE
EMC
ISOLATION RESISTANCE
EMC EMISSION
EMC IMMUNITY
OTHERS
NOTE
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level (surge 4KV), criteria B, EAC TP TC 020
MTBF
316.2Khrs min. MIL-HDBK-217F (25
℃
)
167*53*29.5mm (L*W*H)
DIMENSION
0.27Kg; 36pcs/11.2Kg/0.67CUFT
PACKING
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25
℃
of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Please refer to "DRIVING METHODS OF LED MODULE".
5. Derating may be needed under low input voltages. Please check the static characteristics for more details.
6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on
a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to
perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com)
8. Heat Sink HS1,HS2 can not be shorted.
9. Direct connecting to LEDs is suggested, but is not suitable for using additional drivers.
10. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently
connected to the mains.
File Name:HLP-80H-SPEC 2018-01-09
80W Single Output Switching Power Supply
DIMMING OPERATION
HLP-80H
series
FG
AC/N
AC/L
-V
-V
+V
+V
DIM-
DIM+
※
Built-in 3 in 1 dimming function, output constant current level can be adjusted through output connector by 1~10VDC, PWM signal, or connecting
a resistance between DIM+ and DIM-.
※
Please DO NOT connect "DIM-" to "-V".
※
Reference resistance value for output current adjustment (Typical)
10KΩ 20KΩ 30KΩ 40KΩ 50KΩ 60KΩ 70KΩ 80KΩ 90KΩ 100KΩ
Single driver
Resistance
Multiple drivers
value
(N=driver quantity for synchronized
10K
Ω
/N 20K
Ω
/N 30K
Ω
/N 40K
Ω
/N 50K
Ω
/N 60K
Ω
/N 70K
Ω
/N 80K
Ω
/N 90K
Ω
/N 100K
Ω
/N
dimming operation)
OPEN
-----
95%~108%
Percentage of rated current
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
※
1 ~ 10V dimming function for output current adjustment (Typical)
Dimming value
Percentage of rated current
1V
10%
2V
20%
3V
30%
4V
40%
5V
50%
6V
60%
7V
70%
8V
80%
9V
90%
10V
100%
OPEN
95%~108%
※
10V PWM signal for output current adjustment (Typical): Frequency range :100Hz ~ 3KHz
Duty value
Percentage of rated current
10%
10%
20%
20%
30%
30%
40%
40%
50%
50%
60%
60%
70%
70%
80%
80%
90%
90%
100%
100%
OPEN
95%~108%
※Using
the built-in dimming function can't turn the lighting fixture totally dark. Please refer to the connection method below to achieve 0% brightness
of the lighting fixture connecting to the LED power supply unit.
Dimming connection diagram for turning the lighting fixture ON/OFF :
N
FG
L
Relay
Switch
Adjuster
0~100K Ohms resistance
1~10V DC Voltage
10V PWM Signal
Green/
Yellow
Brown
Blue
AC/L
AC/N
HLP-80H
DIM+
DIM-
V(-)
V(+)
Blue
White
Black
Red
LED Lighting Fixture
Using a switch and relay can turn ON/OFF the lighting fixture.
1.Output constant current level can be adjusted through output cable by connecting a resistance or 1~10Vdc or 10V PWM signal between DIM+ and DIM-.
2.The LED lighting fixture can be turned ON/OFF by the switch.
File Name:HLP-80H-SPEC 2018-01-09