DATA SHEET
The FCX –A2 small flange remote seal type pressure trans-
mitter accurately measures gauge pressure and transmits a
proportional 4 to 20mA signal.
The transmitter utilizes a unique micromachined capaci-
tance silicon sensor with state-of-the-art microprocessor
technology to provide exceptional performance and func-
tionality.
Totally welded construction of the seals assures excellent
reliability in high temperature and highly corrosive process
conditions.
FKW...4
FEATURES
1. Directly connectable to 1-1/2in and 2in flanges
The transmitter is connectable to 1-1/2in and 2in pipes
without a reducer.
2. Connectable to 1/2in and 3/4in pipes
Use of direct mounting adapter allows the transmitter to
be connected to the following process.
1/2in and 3/4in flanges
Screw connection 1/2-14NPT, 3/4-14NPT, Rc1/2, Rc3/4
3. Minimum environmental influence
The “Floating Cell” design which protects the pressure
sensor against changes in temperature, and overpressure
substantially reduces total measurement error in actual
field applications.
4. Fuji/HART
®
bilingual communications protocol and
FOUNDATION™ fieldbus and Profibus™ compatibility
FCX–A2 series transmitter offers bilingual communica-
tions to speak both Fuji proprietary protocol and HART
®
.
Any HART
®
compatible devices can communicate with
FCX–A2. Further, by upgrading electronics FOUNDA-
TION™ fieldbus and Profibus™ are also available.
5. Application flexibility
Various options that render the FCX–A2 suitable for
almost any process applications include:
– Analog indicator at either the electronics side or ter-
minal side
– Full range of hazardous area approvals
– Built-in RFI filter and lightning arrester
– 5-digit LCD meter with engineering unit
– Stainless steel electronics housing
– Wide selection of materials
– High temperature, vacuum seals
6. Burnout current flexibility (Under Scale: 3.2 to 3.8mA,
Over Scale: 20.8 to 21.6mA)
Burnout signal level is adjustable using Model FXW Hand
Held Communicator (HHC) to comply with NAMUR NE43.
7. Dry calibration without reference pressure
Thanks to the best combination of unique construction
of mechanical parts (Sensor unit) and high performance
electronics circuit (Electronics unit), reliability of dry
calibration without reference pressure is at equal level
as wet calibration.
EDSX5-82k
Date
Apr. 3, 2007
DM9000 cannot connect in eboot
RT, the platform is 2440+wince5.0. Now I want to download the image through Ethernet in eboot. I found the code in DM9000 on the Internet, modified the iobase, read the ID correctly, and then after th...
zzzzmmmm Embedded System
Headhunting company hardware positions
Recruitment positions 1. Management positions Technical department director 1. Master degree or above, major in computer, integrated circuit design or embedded system; 2. More than 5 years of technica...
mfxbb Embedded System
Emifa nandflash driver for tms320c6747
Is there any emifa nandflash driver for tms320c6747 (evmomapl137)? It's urgent, it's related to my salary issue, I need to get it done this week. There are still three days left. I read the emifa manu...
georon DSP and ARM Processors
Zigbee routing analysis
The routing analysis process involves routing tables, routing discovery tables, neighbor node tables, RREQ, RREP, and RERR.Routing table : contains the next hop node address, routing status, and desti...
wateras1 RF/Wirelessly
Proteus simulation timestep too small
When using proteus simulation, a prompt "timestep too small" appears. The circuit seems quite simple. Could you please tell me how to solve this problem? If I need to adjust the settings, how do I adj...
renliang25 Microchip MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1022  2852  2085  1628  796  21  58  42  33  17 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号