EEWORLDEEWORLDEEWORLD

Part Number

Search

2200DGF150822SB

Description
Strain Guage Sensor, Gage, 0Psi Min, 15Psi Max, 0.15%, 1-11V, Cylindrical
CategoryThe sensor    Sensor/transducer   
File Size507KB,4 Pages
ManufacturerGems Sensors & Controls
Download Datasheet Parametric View All

2200DGF150822SB Overview

Strain Guage Sensor, Gage, 0Psi Min, 15Psi Max, 0.15%, 1-11V, Cylindrical

2200DGF150822SB Parametric

Parameter NameAttribute value
Is it Rohs certified?incompatible
Reach Compliance Codeunknow
Maximum accuracy(%)0.15%
shellSTAINLESS STEEL
Nominal offset1V
Maximum operating temperature80 °C
Minimum operating temperature-20 °C
Output range1-11V
Output typeANALOG VOLTAGE
Package Shape/FormCYLINDRICAL
port type1/8 NPT
Maximum pressure range15 Psi
Minimum pressure range
Pressure sensing modeGAGE
Sensor/Transducer TypePRESSURE SENSOR,STRAIN GUAGE
Maximum supply voltage35 V
Minimum supply voltage1.5 V
Termination typePLASTIC CABLE GLAND
Base Number Matches1
TI TMS320C6678 Evaluation Module
TMS320C6678 Lite Evaluation ModuleThe TMS320C6678 Lite Evaluation Module (EVM) is an easy-to-use, cost-effective development tool that helps developers quickly start designing with the C6678 or C6674 ...
灞波儿奔 DSP and ARM Processors
The output voltage of the Zener diode is too low
Z1 uses ON Semiconductor's MMSZ5231BT1G. The voltage on C12 was about 4.6V before, but now it is only about 4.4V. If it is too low, the battery will start, and the power consumption is high, so it can...
MMSZ5231BT1G Analog electronics
Openwrt webif open source router control page development (CGI based on shell script)
Hello everyone: Recently, the company has launched a new project, but they are short of manpower, so they temporarily transferred me to develop the control page of Openwrt webif open source router. Th...
iyj Embedded System
Understand data center solutions in seconds
Today’s data centers need to process massive amounts of data from millions of mobile devices and other items that make up the Internet of Things. To keep these facilities running properly, data center...
EEWORLD社区 Discrete Device
BlueNRG ADC2 reads back incorrect voltage value
I am using the development board (STEVAL-IDB009V1) to test the ADC Polling Demo program and found that when the ADC1 pin is selected for input, the voltage value read back is normal, 2.7V, but when th...
Roy_LDH ST - Low Power RF
ATmega2560 output signal inversion
I am a beginner in AVR and I output a PWM signal, but the output signal level is negative.How can I perform the flip processing to make the signal level positive?...
yatjay Microchip MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2490  450  2618  1977  2776  51  10  53  40  56 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号