EEWORLDEEWORLDEEWORLD

Part Number

Search

801-010-02ZN9-4PB

Description
Circular Connector, 4 Contact(s), Aluminum Alloy, Male, Crimp Terminal, Receptacle,
CategoryThe connector    The connector   
File Size317KB,4 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Download Datasheet Parametric View All

801-010-02ZN9-4PB Overview

Circular Connector, 4 Contact(s), Aluminum Alloy, Male, Crimp Terminal, Receptacle,

801-010-02ZN9-4PB Parametric

Parameter NameAttribute value
MakerGlenair
Reach Compliance Codecompliant
Other featuresPOLARIZED
Back shell typeSOLID
Body/casing typeRECEPTACLE
Connector typeCIRCULAR CONNECTOR
Contact to complete cooperationNOT SPECIFIED
Contact point genderMALE
Coupling typeTHREADED
DIN complianceNO
empty shellYES
Filter functionNO
IEC complianceNO
MIL complianceNO
Plug informationMULTIPLE MATING PARTS AVAILABLE
Mixed contactsNO
Installation typePANEL
OptionsGENERAL PURPOSE
Shell surfaceZINC-NICKEL WITH CHROMATE
Shell materialALUMINUM ALLOY
Housing size9
Termination typeCRIMP
Total number of contacts4
A
B
C
D
E
F
G
H
J
K
L
-07
Jam Nut for Rear
M
© 2007 Glenair, Inc.
Series 801
Series 801 “Mighty Mouse”
Double-Start ACME Thread
Series 801 Receptacles – Crimp Termination
In-Line
801-009-01
Rear Panel Jam Nut Mount
801-009-07
Square Flange Mount
801-009-02
Integral Band Platform
for direct attachment of a cable
shield using a
BAND-IT®
strap. Install a boot, or overmold
onto the band platform. An accessory thread is available
for attaching strain reliefs and backshells.
Three Shell Options:
Jam nut with o-ring for rear panel
mounting, square flange or in-line receptacle for free-hanging
cables.
HOW TO ORDER
Sample Part Number
80 1- 0 1 0
Series
-02
Shell Style
Z1
Shell Material /
Finish
C
Aluminum / Black
Anodize
16-5 5
Shell Size- Insert
Arrangement
5-3
6-1
6-4
6-7
7-1
7-10
8-13
9-4
9-19
10-26
13-2
13-37
16-55
17-85
3 #23
1 #16
4 #23
7 #23
1 #12
10 #23
13 #23
4 #16
19 #23
26 #23
2 #12
37 #23
55 #23
85 #23
S
Contact Type
A
Shell Key
Position
M
801-009
Receptacle with
Banding Platform
-01
In-Line
Aluminum / Electroless
Nickel
Standard #23 contacts
A
accept #22 through
Normal
#28 AWG wire. Use the
following contact codes
to specify these contacts: Alternate Key
Positions:
P
Pin
NF
Aluminum / Cadmium
with Olive Drab
Chromate
S
Socket
Special contacts for
#26 to #30 AWG are
also available. Use the
following contact codes
to specify these contacts:
B
C
D
ZN
801-010
Receptacle with
Accessory Thread
-02
Square Flange
for Front or Rear
Mounting
Aluminum / Zinc-
Nickel with Olive Drab
Chromate
ZNU
Aluminum / Zinc-Nickel
with Black Chromate
#23 contacts are packaged
with connectors. #16 and #12
contacts must be ordered
separately.
G
Pin
Z1
Stainless Steel /
Passivated
H
Socket
CAGE Code 06324
Printed in U.S.A.
GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497 • 818-247-6000 • FAX 818-500-9912
www.glenair.com
D-6
Rev. 05-APR-2007
E-Mail: sales@glenair.com
High performance electronic ballast system and its dedicated integrated controller
Abstract: This paper discusses the circuit structure and basic principle of power factor correction circuit that must be possessed by high-performance electronic ballast system, and introduces the ele...
zbz0529 Industrial Control Electronics
About the accuracy of DCO frequency of MSP430G2553
I need an expert to explain this. I want to make a frequency meter for high frequency. I need to use a 1ms delay to measure the number of pulses in this 1ms. However, the result has a large error. I s...
nlls1990 Microcontroller MCU
Foreigner's keyboard scanning library program
/********************************************************************************* PIC ADVANCED UNIVERSAL KEYPAD LIBRARY********************************************************************************...
呱呱 MCU
There is no industry standard for field networks (8) - what are we worried about?
[b][u][size=16px]Myth #8 - Wireless won't integrate with my legacy host system[/size][/u][/b] Wireless networking is new to process automation, but it's not new to your legacy DCS, PLC, data historian...
小瑞 RF/Wirelessly
An error when asking sysgen
Error during sysgen: CEBUILD: Running sysgen -p rdp postproc Starting sysgen phase for project (rdp ) Sysgening platform D:\WINCE500\platform\CEPC Sysgening platform D:\WINCE500\platform\CEPC \WINCE50...
dhmgwb333 Embedded System
About Circuit Attenuation
:funk: What does this circuit mean? It is said to be a signal attenuation circuit. What is the specific principle?...
youngcraft Analog electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1678  396  1837  1147  2449  34  8  37  24  50 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号