90W AC-DC Single Output Desktop
Features :
Universal AC input / Full range
3 pole AC inlet IEC320-C14
GS90
series
Built-in active PFC function, PF>0.91
Protections: Short circuit / Overload / Over voltage / Over temperature
Fully enclosed plastic case
Approvals: UL / CUL / PSE / TUV / BSMI / CCC / CB / FCC / CE
Class power (with earth pin)
Pass LPS
LED indicator for power on
No load power consumption<0.5W
ErP step2 compliant
NRCan compliant
Meet EISA 2007 (Energy Independence and Security Act)
2 years warranty
SPECIFICATION
ORDER NO.
SAFETY MODEL NO.
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER (max.)
OUTPUT
VOLTAGE TOLERANCE
Note.4
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
POWER FACTOR (Typ.)
INPUT
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (max.)
LEAKAGE CURRENT(max.)
OVERLOAD
PROTECTION OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
SAFETY & WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC
(Note. 7)
EMC EMISSION
EMC IMMUNITY
OTHERS
MTBF
DIMENSION
PACKING
PLUG
CABLE
Note.5
Note.6
(except for 48V)
TUV
Rheinland
Product Safety
geprUfre
Sicherheit
GS90A12-P1M
GS90A12
Note.2
12V
GS90A15-P1M
GS90A15
15V
6A
0 ~ 6A
90W
100mVp-p
5.0%
1.0%
5.0%
GS90A19-P1M
GS90A19
19V
4.74A
0 ~ 4.74A
90W
150mVp-p
4.0%
1.0%
4.0%
GS90A24-P1M
GS90A24
24V
3.75A
0 ~ 3.75A
90W
180mVp-p
3.0%
1.0%
3.0%
GS90A48-P1M
GS90A48
48V
1.87A
0 ~ 1.87A
90W
240mVp-p
2.0%
1.0%
2.0%
6.67A
0 ~ 6.67A
80W
5.0%
1.0%
5.0%
RIPPLE & NOISE (max.)
Note.3
80mVp-p
Note.8
1000ms, 20ms / 230VAC
1000ms, 20ms / 115VAC at full load
20ms / 230VAC
20ms / 115VAC at full load
Note.9
90 ~ 264VAC 127 ~ 370VDC
47 ~ 63Hz
PF>0.91 / 230VAC
88%
2A / 115VAC
70A / 230VAC
1mA / 240VAC
110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
105 ~ 135% rated output voltage
Protection type : Shut down o/p voltage, re-power on to recover
RTH30 > 100
Protection type : Shut down o/p voltage, re-power on to recover
-30 ~ +50 (Refer to "Derating Curve")
20% ~ 90% RH non-condensing
-40 ~ +85
, 10 ~ 95% RH
0.03% / (0~50 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1, BSMI CNS14336, CCC GB4943,
J60950-1(except for 48V)
approved
I/P-O/P: 3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 class B, EN61000-3-2,3, FCC PART 15 / CISPR22 class B, CNS13438 class B, GB9254 class B, GB17625.1
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A
348.7Khrs min. MIL-HDBK-217F(25 )
145*60*32mm (L*W*H)
0.45Kg; 30pcs/14.05Kg/1CUFT
Standard type P1M: 2.5 * 5.5 * 11mm, tuning fork type, center positive for stock ; Other type available by customer requested
See page 2 ; Other type available by customer requested
PF>0.95 / 115VAC at full load
89%
1A / 230VAC
89%
89.5%
91%
CONNECTOR
NOTE
1. All parameters are specified at 230VAC input, rated load, 25 70% RH ambient.
2. DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3. Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4. Tolerance: includes set up tolerance, line regulation, load regulation.
5. Line regulation is measured from low line to high line at rated load.
6. Load regulation is measured from 10% to 100% rated load
7. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives.
8. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
9. Derating may be needed under low input voltages. Pleas check the derating curve for more details.
File Name:GS90-SPEC 2012-03-06