EEWORLDEEWORLDEEWORLD

Part Number

Search

GS90A12-P1M

Description
PowerSupply;AC-DC;24V@3.75A;90-264VIn;Desktop;Retail;Switching;90W;GSSeries
Categoryunclassified   
File Size144KB,2 Pages
ManufacturerMEAN WELL
Websitehttp://www.meanwell.com
Download Datasheet Compare View All

GS90A12-P1M Online Shopping

Suppliers Part Number Price MOQ In stock  
GS90A12-P1M - - View Buy Now

GS90A12-P1M Overview

PowerSupply;AC-DC;24V@3.75A;90-264VIn;Desktop;Retail;Switching;90W;GSSeries

90W AC-DC Single Output Desktop
Features :
Universal AC input / Full range
3 pole AC inlet IEC320-C14
GS90
series
Built-in active PFC function, PF>0.91
Protections: Short circuit / Overload / Over voltage / Over temperature
Fully enclosed plastic case
Approvals: UL / CUL / PSE / TUV / BSMI / CCC / CB / FCC / CE
Class power (with earth pin)
Pass LPS
LED indicator for power on
No load power consumption<0.5W
ErP step2 compliant
NRCan compliant
Meet EISA 2007 (Energy Independence and Security Act)
2 years warranty
SPECIFICATION
ORDER NO.
SAFETY MODEL NO.
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER (max.)
OUTPUT
VOLTAGE TOLERANCE
Note.4
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
POWER FACTOR (Typ.)
INPUT
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (max.)
LEAKAGE CURRENT(max.)
OVERLOAD
PROTECTION OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
SAFETY & WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC
(Note. 7)
EMC EMISSION
EMC IMMUNITY
OTHERS
MTBF
DIMENSION
PACKING
PLUG
CABLE
Note.5
Note.6
(except for 48V)
TUV
Rheinland
Product Safety
geprUfre
Sicherheit
GS90A12-P1M
GS90A12
Note.2
12V
GS90A15-P1M
GS90A15
15V
6A
0 ~ 6A
90W
100mVp-p
5.0%
1.0%
5.0%
GS90A19-P1M
GS90A19
19V
4.74A
0 ~ 4.74A
90W
150mVp-p
4.0%
1.0%
4.0%
GS90A24-P1M
GS90A24
24V
3.75A
0 ~ 3.75A
90W
180mVp-p
3.0%
1.0%
3.0%
GS90A48-P1M
GS90A48
48V
1.87A
0 ~ 1.87A
90W
240mVp-p
2.0%
1.0%
2.0%
6.67A
0 ~ 6.67A
80W
5.0%
1.0%
5.0%
RIPPLE & NOISE (max.)
Note.3
80mVp-p
Note.8
1000ms, 20ms / 230VAC
1000ms, 20ms / 115VAC at full load
20ms / 230VAC
20ms / 115VAC at full load
Note.9
90 ~ 264VAC 127 ~ 370VDC
47 ~ 63Hz
PF>0.91 / 230VAC
88%
2A / 115VAC
70A / 230VAC
1mA / 240VAC
110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
105 ~ 135% rated output voltage
Protection type : Shut down o/p voltage, re-power on to recover
RTH30 > 100
Protection type : Shut down o/p voltage, re-power on to recover
-30 ~ +50 (Refer to "Derating Curve")
20% ~ 90% RH non-condensing
-40 ~ +85
, 10 ~ 95% RH
0.03% / (0~50 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1, BSMI CNS14336, CCC GB4943,
J60950-1(except for 48V)
approved
I/P-O/P: 3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 class B, EN61000-3-2,3, FCC PART 15 / CISPR22 class B, CNS13438 class B, GB9254 class B, GB17625.1
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A
348.7Khrs min. MIL-HDBK-217F(25 )
145*60*32mm (L*W*H)
0.45Kg; 30pcs/14.05Kg/1CUFT
Standard type P1M: 2.5 * 5.5 * 11mm, tuning fork type, center positive for stock ; Other type available by customer requested
See page 2 ; Other type available by customer requested
PF>0.95 / 115VAC at full load
89%
1A / 230VAC
89%
89.5%
91%
CONNECTOR
NOTE
1. All parameters are specified at 230VAC input, rated load, 25 70% RH ambient.
2. DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3. Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4. Tolerance: includes set up tolerance, line regulation, load regulation.
5. Line regulation is measured from low line to high line at rated load.
6. Load regulation is measured from 10% to 100% rated load
7. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives.
8. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
9. Derating may be needed under low input voltages. Pleas check the derating curve for more details.
File Name:GS90-SPEC 2012-03-06

GS90A12-P1M Related Products

GS90A12-P1M GS90_12 GS90A15-P1M GS90A24-P1M
Description PowerSupply;AC-DC;24V@3.75A;90-264VIn;Desktop;Retail;Switching;90W;GSSeries PowerSupply;AC-DC;24V@3.75A;90-264VIn;Desktop;Retail;Switching;90W;GSSeries PowerSupply;AC-DC;24V@3.75A;90-264VIn;Desktop;Retail;Switching;90W;GSSeries PowerSupply;AC-DC;24V@3.75A;90-264VIn;Desktop;Retail;Switching;90W;GSSeries
Newbie asks about basic questions of WINCE development
I would like to ask what tools (software + hardware) are needed to learn WINCE development? What knowledge is needed? Where can I download or buy the tools? If you know, please tell me, thank you! I w...
mecerdes Embedded System
[Evaluation of domestic FPGA Gaoyun GW1N series development board]——(2) Lighting and running lights
[i=s]This post was last edited by chg0823 on 2021-12-16 00:39[/i]I received the Gaoyun FPGA GW1N-4B development board and was surprised when I opened it. There were so many LEDs connected to it that I...
chg0823 Domestic Chip Exchange
Does anyone know the detailed steps on how to integrate Visual Studio.NET 2005 with Platform Builder for Windows CE 6.0?
I want to learn Windows CE embedded development and system customization, but after installing Visual Studio.NET 2005, I don’t know how to integrate Platform Builder for Windows CE 6.0 into Visual Stu...
wzp9999 Embedded System
ADI Process Control and Industrial Automation Anthology
[i=s]This post was last edited by damiaa on 2018-4-29 11:23[/i] [b][color=#5E7384]This content is originally created by EEWORLD forum user [size=3]damiaa[/size]. If you need to reprint or use it for c...
damiaa ADI Reference Circuit
Will frequent power-off and power-on of the system change the MCU program?
I tested two samples. Due to restrictions, I had to power them off and then power them on. Now I find that the data returned is completely different from when the program was first burned.These two sa...
zeng_jinliang Microcontroller MCU
Mitsubishi PLC Online Learning System
Mitsubishi's pipe network is much better now than before. There are many Chinese software and manuals for download. There is also an online learning system. After taking the online exam, you can get a...
sankyo_feng Industrial Control Electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1920  2750  2382  239  2768  39  56  48  5  8 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号