EEWORLDEEWORLDEEWORLD

Part Number

Search

HLN-40H-36

Description
40W Single Output Switching Power Supply
File Size340KB,5 Pages
ManufacturerMEAN WELL
Websitehttp://www.meanwell.com
Download Datasheet Compare View All

HLN-40H-36 Overview

40W Single Output Switching Power Supply

40W Single Output Switching Power Supply
Features :
HLN-40H
series
Universal AC input / Full range (up to 305VAC)
Built-in active PFC function
Protections: Short circuit / Over current / Over voltage / Over temperature
Cooling by free air convection
OCP point adjustable through output cable or internal potentiometer
IP64 design for indoor or outdoor installations
Class 2 power unit
Three in one dimming function (1~10Vdc or PWM signal or resistance)
Suitable for LED lighting and moving sign applications
Compliance to worldwide safety regulations for lighting
Suitable for dry / damp locations or outdoor application
3 years warranty
F
110
M
M
SELV
IP64
( for 48V,54V only)
( except for 48V,54V )
HLN-40H-12 A
A : IP64 rated. Output voltage and constant current level can be adjusted through internal potentiometer.
B : IP64 rated. Constant current level adjustable through output cable with 1~10Vdc or 10V PWM signal or resistance.
SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
RATED POWER
HLN-40H-12
12V
3.33A
40W
CONSTANT CURRENT REGION
Note.4
7.2 ~12V
HLN-40H-15
15V
9 ~ 15V
2.67A
40W
150mVp-p
HLN-40H-20
20V
12 ~ 20V
2A
40W
150mVp-p
17 ~ 22V
1.2 ~ 2A
1.0%
0.5%
HLN-40H-24
24V
14.4 ~ 24V
1.67A
40.1W
150mVp-p
22 ~ 27V
1 ~ 1.67A
1.0%
0.5%
0.5%
HLN-40H-30
30V
18 ~ 30V
1.34A
40.2W
200mVp-p
27 ~ 33V
0.8 ~ 1.34A
1.0%
0.5%
0.5%
HLN-40H-36
36V
21.6 ~ 36V
1.12A
40.3W
200mVp-p
33 ~ 40V
HLN-40H-42
42V
25.2 ~ 42V
0.96A
40.3W
300mVp-p
40 ~ 46V
HLN-40H-48
48V
28.8 ~ 48V
0.84A
40.3W
300mVp-p
44 ~ 53V
HLN-40H-54
54V
32.4 ~ 54V
0.75A
40.5W
300mVp-p
49 ~ 58V
0.45 ~ 0.75A
1.0%
0.5%
0.5%
RIPPLE & NOISE (max.)
Note.2
150mVp-p
OUTPUT
VOLTAGE ADJ. RANGE
Note.6
10.8 ~ 13.5V 13.5 ~ 17V
CURRENT ADJ. RANGE
VOLTAGE TOLERANCE
Note.3
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
POWER FACTOR (Typ.)
INPUT
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT(Typ.)
LEAKAGE CURRENT
OVER CURRENT
SHORT CIRCUIT
Note.4
Can be adjusted by internal potentiometer or through output cable
2 ~ 3.33A
2.5%
0.5%
1.6 ~ 2.67A
2.0%
0.5%
0.67 ~ 1.12A 0.58 ~ 0.96A 0.5 ~ 0.84A
1.0%
1.0%
1.0%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
1.5%
1.0%
2.0%
Note.7
1500ms, 80ms / 115VAC at full load
16ms/230VAC
Note.5
90 ~ 305VAC
1000ms, 80ms / 230VAC at full load
16ms/115VAC at full load
127 ~ 431VDC
47 ~ 63Hz
PF>0.98/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
87.5%
86.5%
0.43A / 115VAC
0.24A / 230VAC
COLD START 70A/230VAC
<0.75mA / 277VAC
95 ~ 108%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Hiccup mode, recovers automatically after fault condition is removed
41 ~ 49V
15 ~ 21V
18 ~ 24V
23 ~ 30V
35 ~ 43V
48 ~ 58V
28 ~ 35V
Protection type : Shut down o/p voltage, re-power on to recover
70
10 (RTH2)
Protection type : Shut down o/p voltage, re-power on to recover
-40 ~ +50
(Refer to "Derating Curve")
20 ~ 95% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH
0.03%/
(0 ~ 40 )
10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes
UL8750, CSA C22.2 No. 250.0-08 (except for 48V, 54V), EN61347-1, EN61347-2-13 independent , IP64, J61347-1, J61347-2-13
approved ; design refer to UL60950-1, TUV EN60950-1, EN60335-1
I/P-O/P:3.75KVAC
I/P-FG:1.88KVAC
O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55015, EN61000-3-2 Class C ( 60% load) ; EN61000-3-3
Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, EN55024, light industry level (surge 4KV), criteria A
336.5Khrs min. MIL-HDBK-217F (25 )
161*61.5*35mm (L*W*H)
0.35Kg;32pcs/12.2Kg/1.10CUFT
86.5%
88.5%
88%
0.23A / 277VAC
88.5%
88.5%
89%
89%
PROTECTION
OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP.
54 ~ 63V
59 ~ 68V
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
SAFETY & WITHSTAND VOLTAGE
EMC
ISOLATION RESISTANCE
EMC EMISSION
EMC IMMUNITY
MTBF
OTHERS
DIMENSION
PACKING
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Constant current operation region is within 60% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
5. Derating may be needed under low input voltages. Please check the static characteristics for more details.
6. Type A only.
7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
File Name:HLN-40H-SPEC 2012-03-01

HLN-40H-36 Related Products

HLN-40H-36 HLN-40H_12 HLN-40H-12 HLN-40H-15 HLN-40H-24 HLN-40H-42 HLN-40H-48 HLN-40H-54
Description 40W Single Output Switching Power Supply 40W Single Output Switching Power Supply 40W Single Output Switching Power Supply 40W Single Output Switching Power Supply 40W Single Output Switching Power Supply 40W Single Output Switching Power Supply 40W Single Output Switching Power Supply 40W Single Output Switching Power Supply
What is a microcontroller
MCU is the abbreviation of single-chip microcomputer. Since MCU is mainly used in the control field, it is also usually called microcontroller in the world. Both MCU and microcomputer are composed of ...
成都亿佰特 51mcu
DK-LM3S9B96
I'm currently learning CAN, using the CANOPEN protocol. I've already gotten a handle on sending and receiving a single message, but I'm still not clear on how to write a communication program. I'd lik...
kai182 Microcontroller MCU
TI Stellaris M4/M3 MCU Selection Table
The latest 2011 Stellaris series chip selection table has updated the LM4F series products and lists the series to which the chips belong, such as Tempest, Sandstorm, etc. It can help customers choose...
aoxiaoche918 Microcontroller MCU
There are problems with both the transmission and reception of cc1100
There seems to be no problem with transmission. But there are big problems with reception. . . . . . . . . . Could that expert send me a reference program to look at? I would be very grateful... [emai...
cy330206 RF/Wirelessly
Serial port sending program of msp430g2553
[align=left][color=#252525]#include [/color][/align][align=left][color=#252525]#include [/color][/align][align=left][color=#252525]#include#define LCD_EN_PORT P1OUT //The following 2 items should be s...
fish001 Microcontroller MCU
Engineers take you to get started with embedded Linux
ARM+LINUX route, focusing on embedded Linux operating system and its application software development goals: (1) Master the structure and principle of mainstream embedded microprocessors (initially de...
edu1182016 Linux and Android

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1538  94  2458  1620  889  31  2  50  33  18 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号