EEWORLDEEWORLDEEWORLD

Part Number

Search

803-003-07ZNU9-19SY

Description
Circular Connector, 19 Contact(s), Aluminum Alloy, Female, Crimp Terminal, Receptacle,
CategoryThe connector    The connector   
File Size263KB,4 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Download Datasheet Parametric View All

803-003-07ZNU9-19SY Overview

Circular Connector, 19 Contact(s), Aluminum Alloy, Female, Crimp Terminal, Receptacle,

803-003-07ZNU9-19SY Parametric

Parameter NameAttribute value
MakerGlenair
Reach Compliance Codecompliant
ECCN codeEAR99
Factory Lead Time17 weeks 1 day
Other featuresPOLARIZED
Back shell typeSOLID
Body/casing typeRECEPTACLE
Connector typeCIRCULAR CONNECTOR
Contact to complete cooperationNOT SPECIFIED
Contact point genderFEMALE
Coupling typeBAYONET
DIN complianceNO
empty shellNO
Filter functionNO
IEC complianceNO
MIL complianceNO
Plug informationMULTIPLE MATING PARTS AVAILABLE
Mixed contactsNO
Installation typeCABLE AND PANEL
OptionsGENERAL PURPOSE
Shell surfaceZINC NICKEL WITH CHROMATE PLATED
Shell materialALUMINUM ALLOY
Housing size9
Termination typeCRIMP
Total number of contacts19
Series 803 “Mighty Mouse”
¼ Turn Bayonet Coupling
Series 803 Bayonet Crimp Receptacles
A
B
F
D
E
6–7
Shell Size- Insert
Arrangement
5-3
6-1
6-4
6-7
7-1
7-10
8-13
9-4
9-19
10-26
12-2
12-37
14-55
15-85
3 #23 Contacts
1 #16 Contact
4 #23 Contacts
7 #23 Contacts
1 #12 Contact
10 #23 Contacts
13 #23 Contacts
4 #16 Contacts
19 #23 Contacts
26 #23 Contacts
2 #12 Contacts
37 #23 Contacts
55 #23 Contacts
85 #23 Contacts
Push-To-Mate, ¼ Turn to Lock.
These quick-mating connectors feature
bayonet pins on the receptacle. Simply
push the connectors together, then
rotate the plug coupling nut 90° to lock
the connectors together.
Three Shell Mounting Options:
Jam nut with o-ring for rear panel
mounting, elliptical flange for front
or rear panel mounting, or in-line
receptacles for free-hanging cables.
Two Shell Styles:
Choose the integral
band platform for direct attachment
of a cable shield. Install a heat-shrink
boot, or overmold directly onto the
band platform. An accessory thread is
available for attaching strain reliefs and
backshells.
HOW TO ORDER
Sample Part Number
80 3 - 003
Series
803-003
Receptacle with
Banding Platform
for Direct
Attachment of
Cable Shield and
Overmold
-0 7
Shell Style
NF
Shell Material /
Finish
C
Aluminum / Black
Anodize
S
Contact Type
P
Pin
N
Shell Key
Position
N
Normal
Alternate
Key
Positions:
-07
Jam Nut
S
Socket
Standard #23 contacts
accept #22 through
#28 AWG wire. Special
contacts for #26 to #30
AWG are available. Use
the following contact
codes to specify these
contacts:
M
Aluminum / Electroless
Nickel
NF
-02
Flange Mount
Aluminum / Cadmium
with Olive Drab
Chromate
X
Y
Z
ZN
803-004
Receptacle with
Rear Accessory
Thread
Aluminum / Zinc-
Nickel with Olive Drab
Chromate
G
Pin #2630
ZNU
-01
In-Line
Aluminum / Zinc-Nickel
with Black Chromate
#23 contacts are packaged
with connectors. #16 and #12
contacts must be ordered
separately.
H
Socket #2630
Z1
Stainless Steel /
Passivated
© 2007 Glenair, Inc.
CAGE Code 06324
Printed in U.S.A.
GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497 • 818-247-6000 • FAX 818-500-9912
www.glenair.com
F-5
Rev. 05-APR-2007
E-Mail: sales@glenair.com
Series 803
F
G
H
J
K
L
M
Minimizing Radiated Emissions from uk Regulators
The topology is ideal for generating a negative output voltage from a positive supply voltage. Many systems require a negative supply voltage in order to read signals from certain sensors. Therefore, ...
fish001 Analogue and Mixed Signal
Angry, I'm going to ARM
I looked at the development board I bought and I don’t know what meaningful things I can make to play with. I feel that if I do something bad, I will waste a lot of time. In recent days, I have been t...
终极菜鸟 ARM Technology
What method should be used to detect whether the fan has stopped or is stuck?
How can I detect whether the fan has stopped or is stuck? The fan has 3 wires, one of which is the frequency feedback signal. Is there any way to do this?...
abusama 51mcu
[Transfer] How to protect two-wire transmitter
With an understanding of transmitter design and operation, this article will discuss how to design circuits to protect these systems. Figure 1 shows a basic two-wire transmitter design for reference.F...
dontium Analogue and Mixed Signal
Wish the Electronic Engineering World a Happy Mid-Autumn Festival
The annual Mid-Autumn Festival is coming soon. Sweet mooncakes and special gifts are now the hottest topics among people. It is strange to say that all kinds of strange things can happen in the world....
gaoyanmei Talking
[Keysight Technology Thanksgiving Month Essay Contest] + Voice Recognition Control Keysight Oscilloscope
Oscilloscopes are the "eyes" of hardware engineers and are often used in circuit debugging and hardware fault location. Keysight oscilloscopes are basically multi-channel oscilloscopes that can test m...
qingfeng08 Test/Measurement

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1909  1013  790  2608  1516  39  21  16  53  31 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号