EEWORLDEEWORLDEEWORLD

Part Number

Search

803-004-01M7-10PZ

Description
Circular Connector, 10 Contact(s), Aluminum Alloy, Male, Crimp Terminal, Receptacle,
CategoryThe connector    The connector   
File Size263KB,4 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Environmental Compliance  
Download Datasheet Parametric View All

803-004-01M7-10PZ Overview

Circular Connector, 10 Contact(s), Aluminum Alloy, Male, Crimp Terminal, Receptacle,

803-004-01M7-10PZ Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerGlenair
Reach Compliance Codecompliant
Other featuresPOLARIZED
Back shell typeSOLID
Body/casing typeRECEPTACLE
Connector typeCIRCULAR CONNECTOR
Contact to complete cooperationNOT SPECIFIED
Contact point genderMALE
Contact materialNOT SPECIFIED
Coupling typeBAYONET
DIN complianceNO
empty shellNO
Filter functionNO
IEC complianceNO
MIL complianceNO
Plug informationMULTIPLE MATING PARTS AVAILABLE
Mixed contactsNO
Installation typeCABLE
OptionsGENERAL PURPOSE
Shell surfaceELECTROLESS NICKEL
Shell materialALUMINUM ALLOY
Housing size7
Termination typeCRIMP
Total number of contacts10
Series 803 “Mighty Mouse”
¼ Turn Bayonet Coupling
Series 803 Bayonet Crimp Receptacles
A
B
F
D
E
6–7
Shell Size- Insert
Arrangement
5-3
6-1
6-4
6-7
7-1
7-10
8-13
9-4
9-19
10-26
12-2
12-37
14-55
15-85
3 #23 Contacts
1 #16 Contact
4 #23 Contacts
7 #23 Contacts
1 #12 Contact
10 #23 Contacts
13 #23 Contacts
4 #16 Contacts
19 #23 Contacts
26 #23 Contacts
2 #12 Contacts
37 #23 Contacts
55 #23 Contacts
85 #23 Contacts
Push-To-Mate, ¼ Turn to Lock.
These quick-mating connectors feature
bayonet pins on the receptacle. Simply
push the connectors together, then
rotate the plug coupling nut 90° to lock
the connectors together.
Three Shell Mounting Options:
Jam nut with o-ring for rear panel
mounting, elliptical flange for front
or rear panel mounting, or in-line
receptacles for free-hanging cables.
Two Shell Styles:
Choose the integral
band platform for direct attachment
of a cable shield. Install a heat-shrink
boot, or overmold directly onto the
band platform. An accessory thread is
available for attaching strain reliefs and
backshells.
HOW TO ORDER
Sample Part Number
80 3 - 003
Series
803-003
Receptacle with
Banding Platform
for Direct
Attachment of
Cable Shield and
Overmold
-0 7
Shell Style
NF
Shell Material /
Finish
C
Aluminum / Black
Anodize
S
Contact Type
P
Pin
N
Shell Key
Position
N
Normal
Alternate
Key
Positions:
-07
Jam Nut
S
Socket
Standard #23 contacts
accept #22 through
#28 AWG wire. Special
contacts for #26 to #30
AWG are available. Use
the following contact
codes to specify these
contacts:
M
Aluminum / Electroless
Nickel
NF
-02
Flange Mount
Aluminum / Cadmium
with Olive Drab
Chromate
X
Y
Z
ZN
803-004
Receptacle with
Rear Accessory
Thread
Aluminum / Zinc-
Nickel with Olive Drab
Chromate
G
Pin #2630
ZNU
-01
In-Line
Aluminum / Zinc-Nickel
with Black Chromate
#23 contacts are packaged
with connectors. #16 and #12
contacts must be ordered
separately.
H
Socket #2630
Z1
Stainless Steel /
Passivated
© 2007 Glenair, Inc.
CAGE Code 06324
Printed in U.S.A.
GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497 • 818-247-6000 • FAX 818-500-9912
www.glenair.com
F-5
Rev. 05-APR-2007
E-Mail: sales@glenair.com
Series 803
F
G
H
J
K
L
M
DMA serial port output
I redirected the redirection function to the DMA send buffer. Now I want to read the data in the send buffer. How can I read it out? Can I display it on the serial port after reading it out?...
注孤终 GD32 MCU
Live broadcast with prizes: Renesas Electronics Secure IoT Suite provides you with secure cloud connection solutions
Event details >> [url=https://www.eeworld.com.cn/huodong/Renesas_20181030/][b][font=Segoe UI][size=4][color=#ff0000]Reward live broadcast: Renesas Electronics Secure IoT Suite provides you with secure...
千里千寻722 Integrated technical exchanges
uC/OS-II 51 MCU transplantation, assembly part link error
I want to port a uC/OS-II to a 51 (C8051F040) microcontroller. The C language part is compiled and linked successfully, but the assembly part related to the MCU is compiled successfully but cannot be ...
vvsanny Embedded System
It would be nice if there is a high-speed train from Beijing to Jiangxi.
I went back home recently, and I didn't expect to have to go through so much trouble again. It was really stressful to sit for more than 10 or 20 hours. It would be great if a high-speed train from Be...
wateras1 Talking
Porting modbus/tcp on lm3s9b90
Same topic, want to port modbus protocol on 9B90.I found the freemodbus program and I can roughly understand the underlying definition, but the official website says that it can be used with the TCPIP...
collean Microcontroller MCU
[Help] W5300 UDP cannot receive data
dsp controls W5300 to use UDP to send and receive data with PC. W5300 has no problem with UDP sending, but cannot receive UDP packets from PC. The code is as follows. When debugging in CCS4.2, rxlen (...
warcraftiii Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 997  22  2871  1551  1614  21  1  58  32  33 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号