EEWORLDEEWORLDEEWORLD

Part Number

Search

803-009-DC2Z16-6PY-72

Description
Interconnection Device
CategoryThe connector    The connector   
File Size525KB,4 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Download Datasheet Parametric View All

803-009-DC2Z16-6PY-72 Overview

Interconnection Device

803-009-DC2Z16-6PY-72 Parametric

Parameter NameAttribute value
MakerGlenair
Reach Compliance Codecompliant
Connector typeINTERCONNECTION DEVICE
803-009
Abrasion-Resistant Polyurethane Jacket
provides cold temperature flexibility and
high strength. Low smoke/zero halogen
material meets requirements for low
toxicity.
90% Tinned Copper Braid
is terminated
directly to connector with stainless steel
BAND-IT®
strap.
Watertight Overmold
provides strain
relief and protection.
Overmolded Cordset
Series 803 Harsh Environment Shielded Cordsets
These overmolded cordsets withstand abrasion and chemical exposure. Low smoke zero halogen jacket reduces the amount of
toxic and corrosive gasses emitted during combustion. Cable construction features silver coated stranded conductors with TFE
insulation, tinned copper braid shield and extruded polyurethane jacket. Choose single-ended pigtails or double-ended "back-
to-back" versions. Braid shield is attached directly to connector with
BAND-IT®
straps. Semi-rigid polyamide overmold provides
strain relief and environmental sealing.
Series 801 cordsets are now available with size #20HD, #16 and #12 contacts. Ordering information is found on the following
pages.
F
HARSH ENVIRONMENT CORDSET SPECIFICATIONS
Cable Jacket Material
Cable Shield
Conductors
BAND-IT®
Shield Termination Band
Current Rating
Test Voltage (Dielectric Withstanding Voltage)
Insulation Resistance
Operating Temperature
Solvent Resistance, Polyamide Overmold
Shielding Effectiveness
Cable jacket Flammability and Toxicity
Thermoplastic Polyurethane, Black, Low-Smoke, Zero-Halogen
Tin-Coated Copper Braid, 90% Minimum Coverage
Silver Coated Stranded Wire, TFE Insulated, Per M22759/11
Stainless Steel
#23 5 Amps, #20HD 7.5 Amps, #16 13 Amps, #12 23 Amps
#23 500 VAC, #20HD 700 VAC, #16 and #12 1800 VAC Sea Level
200 megohms minimum
-30° C. to +105° C.
Excellent Resistance to Most Solvents, Fuels, and Oils; Poor Resistance to
Strong Acids and Bipolar Solvents (Alcohol)
50 dB minimum from 100MHz to 1000MHz.
Toxicity Index 3.9 per NES 713
Oxygen Index 28% per ASTM D-2863
Smoke Index 24 per NES 711
© 2010 Glenair, Inc.
www.glenair.com
Dimensions in inches (millimeters) and are subject to change without notice.
CAGE Code 06324
Printed in U.S.A.
E-Mail: sales@glenair.com
GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497 • 818-247-6000 • FAX 818-500-9912
F-15
01-JANUARY-2010
Series 803
Series 803 Mighty Mouse ¼ Turn Bayonet Coupling
Overmolded ASAP Cordset Ordering Information
"【TGF4042 Signal Generator】" Narrow pulse signal output measurement
The signal generator can emit signals of various waveforms, including common sine, square, pulse, Gaussian, etc., uncommon cardiac waveforms, pulse waveforms, various customized waveforms, etc., as sh...
fine0406 Test/Measurement
That green PCB board is tested with these 7 methods
The process of electronic hardware design includes hardware requirements, schematic design, PCB design, PCB manufacturing, UT and integrated testing, etc. Among them, in the PCB board processing and m...
mwkjhl PCB Design
Remote debugging hardware via TCPIP of Altera SoC
Here is an application note from the official website of Altera that I spent half a day translating today....
小梅哥 FPGA/CPLD
The ADC test of STM32 is pretty good, but unfortunately there is no differential channel (pictured)
The picture shows the actual data acquisition board, which is Embest's DEMO board; the program is a random program in the ADC directory, the hardware settings are not changed, the output mode is modif...
kmmmmy stm32/stm8
C-band monopulse radar frequency source
Starting from the basic requirements of modern radar for frequency source, this paper introduces the engineering scheme of excitation source and coherent local oscillator of single pulse precision mea...
JasonYoo Power technology
Repost: Elevators 60 years later, the motherland tells you to save energy! !
[i=s]This post was last edited by paulhyde on 2014-9-15 09:11[/i] If you were asked to design the elevator of the future, what would you start with? Cool appearance, creative structure, extraordinary ...
大骞骞 Energy Infrastructure?

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2559  570  375  1395  1376  52  12  8  29  28 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号