71A30-01-1-02S

Description
Rotary Switch, 2 Positions, SPDT, Latched, Solder Terminal, Shaft Type Actuator, Panel Mount-threaded, ROHS COMPLIANT
CategoryMechanical and electronic products    switch   
File Size1MB,14 Pages
ManufacturerGrayhill
Websitehttp://www.grayhill.com
Environmental Compliance  
Download Datasheet Parametric View All

71A30-01-1-02S Overview

Rotary Switch, 2 Positions, SPDT, Latched, Solder Terminal, Shaft Type Actuator, Panel Mount-threaded, ROHS COMPLIANT

71A30-01-1-02S Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerGrayhill
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
ECCN codeEAR99
Actuator typeSHAFT TYPE
body height18.54 mm
Body length or diameter17.45 mm
Graduation angle30 deg
JESD-609 codee4
Installation featuresPANEL MOUNT-THREADED
Number of positions2
Number of switching segments1
surface mountNO
Switch actionLATCHED
switch functionSPDT
Switch typeROTARY SWITCH
Terminal surfaceGold (Au) - with Nickel (Ni) barrier
Termination typeSOLDER
Multi-Deck Rotary Switches
SERIES 71
.5-.75" Diameter, 1/4 Amp
FEATURES
• Performance and Value Leader
• Molded-In Position Terminals
• Choice of Shaft/Bushing Diameters
• 30° and 36° Angles of Throw
• Military Qualified MIL-DTL-3786/39
DIMENSIONS: Standard and Military
In inches (and millimeters)
0.125" Diameter Shaft–Styles A and MA (and sealed versions)
.687 ± .015
(17,45 ± 0,38)
DIA.
.094 ± .010
(2,39 ± 0,25)
.312 ± .020
(7,92 ± 0,51)
.375 ± .020
(9,53 ± 0,51)
.250 ± .020
(6,35 ± 0,51)
SEE
CHART
C
.203 ± .005
(5,16 ± 0,13)
C
OF POSITION NO. 1
L
C
OF BUSHING FLATS
L
DIM. A ± .046 (1,17)
DIM. B REF.
STUD PROJECTION
(SEE CHARACTER-
ISTICS)
Rear Views–Style A, B, MA, MB
(and sealed versions)
30° and 36° Angle of Throw may be
interposed on either shaft diameter.
30° Angle of Throw
SEE DETAIL
.500 ± .015
(12,7 ± 0,38)
DIA.
.562
± .015
(14,27
± 0,38)
GRAYHILL
10
9
8
1
12
1
1
7
1/4 32UNEF-2A THREAD
SEE NOTE
0.250" Diameter Shaft–Styles B and MB (and sealed versions)
.687 ± .015
(17,45 ± 0,38)
DIA.
.219 ± .004
(5,56 ± 0,10)
.312 ± .020
(7,92 ± 0,51)
.375 ± .020
(9,53 ± 0,51)
.250 ± .020
(6,35 ± 0,51)
SEE
CHART
C
.250 + .001
–.002 DIA.
(6,36 + 0,25
–0,05)
BUSHING KEYWAY
.066 ± .002 (1,68 ± 0,05) WIDE BY
.036 ± .003 (0,91 ± 0,08) DEEP
FROM A .375 (9,53) DIA.
3/8-32UNEF-2A THREAD
Approx.
Weight
Grams
14
16
18
20
22
24
Approx.
Weight
Grams
26
28
30
32
34
36
All dimensions not shown
are the same as above.
.750 ± .020
(19,05 ± 0,51)
OVER TERMINALS
36° Angle of Throw
SEE DETAIL
.500 ± .015
(12,7 ± 0,38)
DIA.
8
7
GRAYHILL
10
9
1
C
OF POSITION NO. 1
L
C
OF BUSHING KEYWAY
L
SEE NOTE
.750 ± .020
(19,05 ± 0,51)
OVER TERMINALS
Note:
Common location for a single pole per
deck switch. For common location on
multipole switches see circuit diagrams.
No. of
Decks
1
2
3
4
5
6
Dimension
A
.761 (19,33)
.979 (24,87)
1.197 (30,40)
1.415 (35,94)
1.633 (41,48)
2.131 (54,13)
Dimension
B
.031
.031
.031
.031
.031
.312
(0,79)
(0,79)
(0,79)
(0,79)
(0,79)
(7,92)
No. of
Decks
7
8
9
10
11
12
Dimension
A
2.349
2.567
2.785
3.003
3.221
3.439
(59,66)
(65,20)
(70,74)
(76,28)
(81,81)
(87,35)
Dimension
B
.312
.312
.312
.312
.312
.312
(7,92)
(7,92)
(7,92)
(7,92)
(7,92)
(7,92)
Terminal Detail
Angle C
is 15° in 12 position switches and 36 ° in 10 position switches.
Grayhill part number and date code marked on detent cover label. Customer part
number marked on request. Military part number marked when required.
.034 ± .003
(0,86 ± 0,08)
Rotary
2
Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois
60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com
5
3
4
2
3
.125 + .001
–.002 DIA.
(3,18 + 0,25
–0,05)
6
2
Rotary Switches
6
5
4
.068 ± .005
(1,73 ± 0,13)
WinC FTP service problem?
Dear experts: I have a problem as follows: I have made an FTP client program under evc and it can run on the simulator, but when I download it to the board and run it, when I log in to the FTP server,...
qyan332713590 Embedded System
An In-depth Conversation on Bypass Capacitors
In-depth dialogue on bypass capacitors [b][size=4][color=#a0522d][/color][/size][/b]...
qwqwqw2088 Analogue and Mixed Signal
Practical C language for MSP430 series microcontrollers (Zhang Xi)
Practical C language for MSP430 series microcontrollers (Zhang Xi)...
yehaiyan Microcontroller MCU
Apply
I have just come into contact with NXP's products and hope to gain a deeper understanding of them and be able to put them into practical use....
mozeat MCU
After installing XP, vmware cannot enter the XP debugging system
I used WinDbg and a virtual machine to debug a Windows driver. However, according to the settings on the webpage, when I entered the virtual machine XP system and chose to enter the XP debugging syste...
fpgafuns Embedded System
How to classify LED driver power supply reliably?
1. LED power supplies can be divided into two categories according to the driving method : A. Constant current type : 1. Constant current drive circuit is ideal for driving LEDs , but the disadvantage...
weleddianyuan LED Zone

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1558  1280  256  1989  2900  32  26  6  41  59 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号