EEWORLDEEWORLDEEWORLD

Part Number

Search

51760-11703610CB

Description
Board Connector, Female, Right Angle, Press Fit Terminal, Guide Pin, Receptacle
CategoryThe connector    The connector   
File Size259KB,3 Pages
ManufacturerAmphenol
Websitehttp://www.amphenol.com/
Download Datasheet Parametric View All

51760-11703610CB Overview

Board Connector, Female, Right Angle, Press Fit Terminal, Guide Pin, Receptacle

51760-11703610CB Parametric

Parameter NameAttribute value
Is it Rohs certified?incompatible
MakerAmphenol
Reach Compliance Codecompliant
Board mount optionsHOLE .138-.163
body width0.47 inch
subject depth0.865 inch
body length8.3 inch
Body/casing typeRECEPTACLE
Connector typeBOARD CONNECTOR
Contact completed and terminatedTIN/LEAD
Contact point genderFEMALE
Contact materialCOPPER ALLOY
Contact resistance20 mΩ
Contact styleHYBRID
Dielectric withstand voltage2500VDC V
Durability200 Cycles
maximum insertion force.973 N
Insulation resistance500000000 Ω
insulator materialGLASS FILLED THERMOPLASTIC
Manufacturer's serial number51760
Mixed contactsYES
Installation option 1GUIDE PIN
Installation option 2LOCKING
Installation methodRIGHT ANGLE
Installation typeBOARD
Number of connectorsONE
Maximum operating temperature105 °C
Minimum operating temperature-55 °C
Rated current (signal)3 A
GuidelineUL
reliabilityCOMMERCIAL
Terminal length0.154 inch
Termination typePRESS FIT
Evacuation force-minimum value.17792 N
PDM: Rev:M
STATUS:
Released
Printed: Dec 20, 2010
.
Ask about "random selection"
Could you please help me find what is wrong? Some cases cannot be selected, I don't know why? #include #include #include//Random number function header file #define uint unsigned int #define uchar uns...
wrlsohu 51mcu
Sensor parameters wiring method
:Cry: I am a complete sensor "newbie", and I have to do some related work recently. I saw a protocol and the wiring method of an oil pressure sensor is 120157914. Please help me, prawns!...
louyangdp Sensor
Serial port printing program on LM3S8962
This is my serial port printing program on LM3S8962 . There are no problems running on LM3S . int CommPrintf( INT8U ch, const char *fmt, ... ) { int i; va_list args; static char buf[128]; #if OS_CRITI...
eeleader Microcontroller MCU
Reliability Analysis of Measurement Results of Electromagnetic Flowmeter
1 Experimental conditions 1.1 Environmental conditions Atmospheric temperature 26.5℃, relative humidity 45%RH, atmospheric pressure 93.1kPa. 1.2 Measurement standard Static mass method water flow stan...
jskmyb Test/Measurement
Electronic circuit and EMI/EMC design analysis
Electronic circuit and EMI/EMC design analysis[ Print ][ Return ]For a good electronic product, in addition to the functions of the product itself, the technical level of circuit design and electromag...
fighting Energy Infrastructure?
HyperTerminal and Yuanfeng Experiment Box serial port cannot communicate
I am a beginner in Linux and now want to transplant Linux into S3C2410. The HyperTerminal and the serial port of Yuanfeng experimental box cannot communicate. The HyperTerminal settings are correct, b...
stdio_h_0 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 718  1694  2885  2852  971  15  35  59  58  20 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号