EEWORLDEEWORLDEEWORLD

Part Number

Search

1241.2822.013

Description
Pushbutton Switch, SPST, N.o.-n.c., Vertical, 0.125A, 48VDC, 0 PCB Hole Cnt, Solder Terminal, Through Hole-straight
CategoryMechanical and electronic products    switch   
File Size2MB,3 Pages
ManufacturerSCHURTER
Websitehttp://www.schurterinc.com/
Environmental Compliance
Download Datasheet Parametric View All

1241.2822.013 Overview

Pushbutton Switch, SPST, N.o.-n.c., Vertical, 0.125A, 48VDC, 0 PCB Hole Cnt, Solder Terminal, Through Hole-straight

1241.2822.013 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
Reach Compliance Codecompli
ECCN codeEAR99
Actuator angle
Actuator materialSTAINLESS STEEL
Actuator stroke0.4 mm
Actuator typePUSHBUTTON
Other featuresVANDAL PROOF
body height8.8 mm
Body length or diameter21.5 mm
center contact materialBRASS
Center contact platingSILVER
Maximum contact current (DC)0.125 A
Contact (DC) maximum rated power R load1.2VA@48VDC
Contact (DC) maximum rated R load.125A@48VDC
Contact resistance1.5 mΩ
Maximum contact voltage (DC)48 V
Electrical life1000000 Cycle(s)
End contact materialBRASS
End contact platingSILVER
Shell materialSTAINLESS STEEL
Insulation resistance1000000 Ω
JESD-609 codee3
Installation featuresPANEL MOUNT
Maximum operating force3.7 N
Maximum operating temperature60 °C
Minimum operating temperature-20 °C
method of packingBOX
sealIK05; IP40; IP65
surface mountNO
Switch actionMOMENTARY
switch functionSPST
Switch typePUSHBUTTON SWITCH
Terminal surfaceMatte Tin (Sn)
Terminal length0.346 inch
Termination typeSOLDER
Base Number Matches1
DATA VANDAL-PROOF MECHANICAL SWITCHES
BENEFITS
Rugged design
Protection against vandalism
Highest quality and long service life due to high-quality materials
Reliable tactile feedback of input
Exceptional price/performance ratio
Versatile color design and lettering
MCS18/22 ES
Electrical data:
Contact material
Switching voltage max.
Switching voltage min.
Switching current max.
Rated breaking capacity
Lifetime (at rated breaking capacity)
Initial contact resistance new
Initial contact resistance after lifetime 1 Mio.
Insulation resistance
Contact bounce
LED supply voltage
LED forward current (max.)
LED forward voltage (I
F
mA)
Mechanical data:
Actuating force
Contact travel
Degree of protection
Protection against external mechanical use (DIN EN 50102)
MCS19
silver*
48
4V
125
0.72
1
< 50
< 150
> 10
8
<5
SSM
Au/Ni
50
3V
50
2.5
20
MCS30
silver*
48
4V
125
gold
[VDC]
[VDC]
[mA]
[W]
[10
6
]
[m
Ω]
[m
Ω]
[Ω]
[ms]
[VDC]
[mA]
[V]
24
50 mV
50
1.2
0.3
< 10
< 30
> 10
8
<5
1
< 50
< 150
> 10
8
1
<5
24 V
45
red green yellow
1.6
2.0
2.0
2.8
1.7
40
IK 07
3.7
0.4
40
Frontside
65
Switch
[N]
[mm]
[IP]
[IK]
2.8
0.3
65
Frontside
40
Rear
3.7
0.4
40
Frontside
65
Switch
IK 05
IK 03
IK 05
Climatic data:
Operating/storage temperature
*
gold on request
[°C]
-25 - +85
-25 - +60
-40 - +85
-25 - +60
www.schurter.com
19
DSP28 fir low-pass filter design source code
#include"stdio.h" #include"math.h" #include"DSP28_Device.h" #defineorder 26 #defineN 128#definepi 3.1415926 floatFIR_LPF[order] ={-1.52864422149721e-05,-0.000133359311426970,-0.000544636220343477,-0.0...
灞波儿奔 Microcontroller MCU
I went to Huaqiangbei to buy tantalum capacitors, but it was a disaster; I went to the online catalog to buy them, but it was a disaster again!
I have also heard about the shortage of tantalum capacitors. Recently, my company made a batch of prototypes, and the damn Layout engineer actually put a lot of tantalum capacitors on them, and used T...
西点 Buy&Sell
How to use DS18B20 on pcduino? ?
How to use DS18B20 on pcduino? ?...
卡娜莱莱 Embedded System
FPGA Audio Processing Problems
I recently used FPGA to perform AD sampling on UDA1341. Has anyone used UDA1341 before? Can the AD and DA of this chip be used at the same time? In addition, the L3 interface of the chip should have n...
kready FPGA/CPLD
ATMEL Car Access Control and Tire Pressure Monitoring System Solutions
This brochure introduces ATMEL's wireless solutions for car access and tire pressure monitoring systems (TPMS)....
frozenviolet Test/Measurement
Solution to PANID conflict found in zstack.
If there are multiple Zigbee networks in the same space at the same time, a possible problem is the conflict of network ID (PANID), which will cause confusion in the Zigbee network. There is no soluti...
kata RF/Wirelessly

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2646  2875  2737  2596  1308  54  58  56  53  27 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号