to minimize resistive DC losses. Long-term hermeticity
is assured through use of parallel seam welded lid
attachment along with International Rectifier’s rugged
ceramic pin-to-package seal. Axial orientation of the
leads facilitates preferred bulkhead mounting to the
principal heat-dissipating surface.
Manufactured in a facility fully qualified to MIL-PRF-38534,
these converters are fabricated utilizing DSCC qualified
processes. For available screening options, refer to
device screening table in the data sheet.
Variations in electrical, mechanical and screening
specifications can be accommodated. Contact IR Santa
Clara for special requirements.
28V Input, Triple Output
ART
Features
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
Total Dose > 100 krad (Si), 2:1margin
SEE Hardened to LET up to 83 Mev
.
cm
2
/mg
Derated per MIL-STD-975 & MIL-STD-1547
Output Power Range 3 to 30 Watts
19 to 50 Volt Input Range
Input Undervoltage Lockout
High Electrical Efficiency > 83%
Full Performance from -55°C to +125°C
Continuous Short Circuit and Overload
Protection
12.8 W/in
3
Output Power Density
True Hermetic Package
External Inhibit Port
Externally Synchronizable
Fault Tolerant Design
5V,
±
12V or
±
15 V Outputs Available
Standard Microcircuit Drawings Available
www.irf.com
1
08/10/06
ART28XXT Series
SPECIFICATIONS
Absolute Maximum/Minimum Ratings
Note 1
Input voltage range
Minimum Output Current
Soldering temperature
Storage temperature
-0.5V to +80V
5% maximum rated
current, any output
300°C for 10 seconds
-65°C to +135°C
Output Power range
Operating temperature
Recommended Operating Conditions
Note 2
Input Voltage range
+19V to +60V
+19V to +50V for full
derating to MIL-STD-975
3.0W to 30W
-55°C to +125°C
-55°C to +85°C for full
derating to MIL-STD-975
Electrical Performance
-55°C < T
CASE
< +125°C, V
IN
=28V, C
L
=0
unless otherwise specified.
Parameter
Output voltage accuracy
Symbol
V
OUT
Conditions
I
OUT
= 1.5Adc, T
C
= +25°C
(main)
Min
4.95
±11.50
±14.50
3.0
(main)
150
75
-15
-60
-180
-300
-10
-500
4.8
±11.1
±13.9
Max
5.05
Units
Vdc
I
OUT
= ±250mAdc, T
C
= +25°C ART2812(dual)
I
OUT
= ±250mAdc, T
C
= +25°C ART2815(dual)
Output power
Note 5
Output current
Note 5
P
OUT
I
OUT
19 Vdc< V
IN
< 50Vdc
19 Vdc< V
IN
< 50Vdc
(dual)
150 mAdc < I
OUT
< 3000 mAdc
Line regulation
Note 3
VR
LINE
19 Vdc< V
IN
< 50Vdc
±75 mAdc < I
OUT
< ±750 mAdc
150 mAdc < I
OUT
< 3000 mAdc
Load regulation
Note 4
VR
LOAD
19 Vdc< V
IN
< 50Vdc
±75 mAdc < I
OUT
< ±750 mAdc
Cross regulation
Note 8
VR
CROSS
(dual)
(main)
19 Vdc< V
IN
< 50Vdc
(dual)
Total regulation
VR
All conditions of Line, Load,
(main)
Cross Regulation, Aging,
Temperature and Radiation ART2812(dual)
ART2815(dual)
I
OUT
= minimum rated, Pin 3 open
Input current
Output ripple voltage
Note 6
Input ripple current
Note 6
Switching frequency
Efficiency
I
IN
Pin 3 shorted to pin 2 (disabled)
V
RIP
I
RIP
F
S
Eff
19 Vdc< V
IN
< 50Vdc
I
OUT
= 3000 mAdc (main), ±500 mAdc (dual)
19 Vdc< V
IN
< 50Vdc
I
OUT
= 3000 mAdc (main), ±500 mAdc (dual)
Sychronization input open. (pin 6)
I
OUT
= 3000 mAdc (main), ±500 mAdc (dual)
(dual)
(main)
(main)
±12.50
±15.15
30
3000
mAdc
750
+15
mV
+60
+180
mV
+300
+10
mV
+500
5.2
V
±12.9
±16.0
250
mA
8.0
70
100
mV
p.p
mA
p.p
KHz
kHz
W
225
83
275
%
For Notes to SPECIFICATIONS, refer to page 3
2
www.irf.com
ART28XXT Series
Electrical Performance
(Continued)
Parameter
Enable Input
open circuit voltage
drive current (sink)
voltage range
Synchronization Input
frequency range
pulse high level
pulse low level
pulse rise time
pulse duty cycle
Synchronization Output
pulse high level
pulse low level
Power dissipation, load fault
Output response to step load
changes
Notes 7, 11
Recovery time from step load
changes
Notes 11, 12
Output response to step line
changes
Notes 10, 11
Recovery time from step line
changes
Notes 10, 11,13
Turn on overshoot
V
OS
Turn on delay
Note 14
Capacitive load
Notes 9, 10
Isolation
T
DLY
CL
ISO
I
OUT
= minimum and full rated
I
OUT
= minimum and full rated
No effect on DC performance
(main)
(dual)
100
P
D
V
TLD
T
TLD
V
TLN
External clock signal on Sync. input (pin 4)
225
4.5
-0.5
40
20
Signal compatible with synchronization input
3.7
0.0
Short circuit, any output
10% Load to/from 50% load
50% Load to/from 100% load
10% Load to/from 50% load
50% Load to/from 100% load
I
OUT
= 3000 mAdc
V
IN
= 19 V to/from 50 V
I
OUT
= ±500 mAdc
I
OUT
= 3000 mAdc
V
IN
= 19 V to/from 50 V
I
OUT
= ±500 mAdc
(main)
(dual)
(main)
(dual)
(main)
(dual)
5.0
-350
-1050
-200
-200
4.3
0.25
16
200
200
200
200
350
mV
PK
1050
500
500
100
500
20
500
100
mV
V
W
mV
PK
310
10.0
0.25
80
Symbol
Conditions
MIN
3.0
0.1
-0.5
MAX
5.0
50.0
Units
V
mA
V
KHz
Khz
V
V
s
V/µS
%
µs
µS
T
TLN
µs
µS
ms
mS
µF
MΩ
500VDC Input to Output or any pin to case
(except pin 12)
Notes to SPECIFICATIONS
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
Operation outside absolute maximum/minimum limits may cause permanent damage to the device. Extended operation at the limits may permanently
degrade performance and affect reliability.
Device performance specified in Electrical Performance table is guaranteed when operated within recommended limits. Operation outside
recommended limits is not specified.
Parameter measured from 28V to 19 V or to 50V while loads remain fixed.
Parameter measured from nominal to minimum or maximum load conditions while line remains fixed.
Up to 750 mA is available from the dual outputs provided the total output power does not exceed 30W.
Guaranteed for a bandwidth of DC to 20MHz. Tested using a 20KHz to 2MHz bandwidth.
Load current is stepped for output under test while other outputs are fixed at half rated load.
Load current is fixed for output under test while other output loads are varied for any combination of minimum to maximum.
A capacitive load of any value from 0 to the specified maximum is permitted without comprise to DC performance. A capacitive load in excess of the
maximum limit may interfere with the proper operation of the converter’s short circuit protection, causing erratic behavior during turn on.
Parameter is tested as part of design characterization or after design or process changes. Thereafter, parameters shall be guaranteed to the limits
specified in the table.
Load transient rate of change, di/dt
≤
2 A/µSec.
Recovery time is measured from the initiation of the transient to where V
OUT
has returned to within ±1% of its steady state value.
Line transient rate of change, dv/dt
≤
50 V/µSec.
Turn on delay time is for either a step application of input power or a logical low to high transition on the enable pin (pin 3) while power is present at the
input.
www.irf.com
3
ART28XXT Series
Group A Tests
V
IN
= 28Volts, C
L
=0
unless otherwise specified.
Test
Output voltage accuracy
Symbol
V
OUT
Conditions unless otherwise specified
I
OUT
= 1.5 Adc
I
OUT
= ±250mAdc
I
OUT
= ±250mAdc
(main)
ART2812(dual)
ART2815(dual)
Group A
Subgroups
1, 2, 3
1, 2, 3
1, 2, 3
1, 2, 3
MIN
4.95
±11.70
±14.50
3.0
150
75
4.8
±11.1
±14.0
MAX
5.05
Units
V
±12.30
±15.15
30
3000
mA
(dual)
1, 2, 3
1, 2, 3
1, 2, 3
1, 2, 3
1, 2, 3
1, 2, 3
1, 2, 3
1, 2, 3
4, 5, 6
1
2, 3
1, 2, 3
4, 5, 6
4, 5, 6
4, 5, 6
4, 5, 6
(main)
4, 5, 6
4, 5, 6
4, 5, 6
1
5.0
100
-200
-200
225
83
81
16
200
mV
PK
50% Load to/from 100% load
200
200
200
100
mV
(dual)
500
20
mS
ms
MΩ
10% Load to/from 50% load
500
5.2
V
2812(dual)
2815(dual)
±12.9
±15.8
250
mA
Pin 3 shorted to pin 2 (disabled)
8.0
70
100
275
mV
P-P
mA
P-P
KHz
%
W
V
IN
= 19 V, 28V, 50 V
I
OUT
= 3000mA main, ±500mA dual
V
IN
= 19 V, 28V, 50 V
I
OUT
= 3000mA main, ±500mA dual
Synchronization pin (pin 6) open
I
OUT
= 3000mA main, ±500mA dual
Short circuit, any output
10% Load to/from 50% load
(main)
W
Output power
Note 1
Output current
Note 1
Output regulation
Note 4
P
OUT
I
OUT
V
IN
= 19 V, 28V, 50 V
(main)
V
IN
19 V, 28V, 50 V
I
OUT
= 150, 1500, 3000mAdc
V
IN
= 19 V, 28V, 50 V
I
OUT
= ±75, ±310, ±625mAdc
I
OUT
= ±75, ±250, ±500mAdc
1, 2, 3
VR
I
OUT
= minimum rated, Pin 3 open
Input current
Output ripple
Note 2
Input ripple
Note 2
Switching frequency
Efficiency
Power dissipation,
load fault
Output response to step
load changes
Notes 3, 5
Recovery time from step
load changes
Notes 5, 6
I
IN
V
RIP
I
RIP
F
S
Eff
P
D
V
TL
T
TL
50% Load to/from 100% load
µs
µS
Turn on overshoot
Turn on delay
Note 7
Isolation
V
OS
T
DLY
ISO
I
OUT
= minimum and full rated
I
OUT
= minimum and full rated
500VDC Input to output or any pin to case
(except pin 12)
Notes to Group A Test Table
1.
2.
3.
4.
5.
6.
7.
8.
Parameter verified during dynamic load regulation tests.
Guaranteed for DC to 20 MHz bandwidth. Test conducted using a 20KHz to 2MHz bandwidth.
Load current is stepped for output under test while other outputs are fixed at half rated load.
Each output is measured for all combinations of line and load. Only the minimum and maximum readings for each output are recorded.
Load step transition time
≥
10µS.
Recovery time is measured from the initiation of the transient to where V
OUT
has returned to within ±1% of its steady state value.
Turn on delay time is tested by application of a logical low to high transition on the enable pin (pin 3) with power present at the input.
Subgroups 1 and 4 are performed at +25ºC, subgroups 2 and 5 at -55ºC and subgroups 3 and 6 at +125ºC.
4
www.irf.com
ART28XXT Series
Radiation Performance
The radiation tolerance characteristics inherent in the
ART28XXT converter are the direct result of a carefully
planned ground-up design program with specific radiation
design goals. After identification of the general circuit
topology, a primary task of the design effort was selection
of appropriate elements from the list of devices for which
extensive radiation effects data was available. By imposing
sufficiently large margins on those electrical parameters
subject to the degrading effects of radiation, designers
were able to select appropriate elements for incorporation
into the circuit. Known radiation data was utilized for input
to PSPICE and RadSPICE in the generation of circuit
Double 11 is coming soon. Tektronix flagship store not only prepares super cost-effective passive voltage probes of 199 yuan and digital storage oscilloscopes of 2499 yuan for everyone, but also prepa...
[i=s]This post was last edited by sonicfirr on 2022-3-10 13:10[/i]In the process of using RVB2601, it is inevitable to use printf() or the LOG output provided by the SDK. In addition, I participated i...
I would like to ask about the example in the spec of TI Led Driver 3406. The formula for calculating Ron is as follows: RON = 1/fSW x 1 x 10-11. Fsw is 500KHz. The calculated Ron should be 200K. But w...
Recently, Teng Li and Liangbing Hu of the University of Maryland in the United States have conducted an experiment that may be able to do this. Their experiment shows that if wood can be used effectiv...
The following two circuits, the former has defects, the output port voltage is unstable. The latter is improved and the problem is solved. Now I need an analysis of the circuit (the cause of the defec...
At present, the development of wireless power supply technology for electric vehicles (EVs) is becoming more and more active. In 2012, Volvo of Sweden established Volvo Technology Japan in Tokyo as...[Details]
1 Introduction
The high temperature tester is mainly used for temperature tracking measurement and data acquisition during the heating process. By systematically analyzing the test data, the...[Details]
As a wireless broadband metropolitan area network standard, WiMAX technology has greater advantages than previous 3.5GHz MMDS products in terms of non-line-of-sight transmission and spectrum utiliz...[Details]
Automotive applications are particularly sensitive to EMI events, which are unavoidable in a noisy electrical environment consisting of a central battery, bundled wiring harnesses, various inductiv...[Details]
In order to highlight the concept of "energy saving and environmental protection" of intelligent buildings, solar street lights are designed for intelligent communities. The inclination and capacit...[Details]
I. Introduction
In the field of power conversion, isolated converters (forward, flyback, and double-ended) with low output DC voltage all use MOSFET as the rectifier device. Since these devi...[Details]
Although it is relatively easy to check the stability of a simple amplifier at lower frequencies, it may be much more difficult to evaluate the stability of a more complex circuit. This artic...[Details]
The automotive lighting and signal control system is responsible for controlling the vehicle's lighting, signal lights, electric horns, reversing and brake buzzers. Traditional automotive lighting...[Details]
The typical fault troubleshooting listed below is for reference of maintenance personnel.
When the computer is turned on, the indicator light is off and there is no screen display
Mainte...[Details]
introduction
MEMS is a high-tech that has flourished on the basis of integrated circuit production technology and dedicated micro-electromechanical processing methods. Pressure sensors develop...[Details]
Today, with energy becoming increasingly scarce, the utilization of natural energy has become the focus of people's attention. Among various natural energies, the endless solar energy is highly fav...[Details]
Only a small number of LED manufacturers can produce high-quality LEDs. For applications that are only used for simple indication, low-quality LEDs are sufficient. However, high-quality LEDs must...[Details]
1. Introduction
With the increasing popularity of fully automatic washing machines, consumers have higher and higher requirements for their environmenta...[Details]
1 Embedded Systems
Embedded System refers to a collection of computer hardware and software with specific functions or purposes, which is divided into embedded software system and embe...[Details]
Currently, the commonly used solar cell technologies include monocrystalline silicon solar cells and polycrystalline silicon thin-film solar cells. Production process: Monocrystalline silicon solar...[Details]