EEWORLDEEWORLDEEWORLD

Part Number

Search

2639LHA1/43301L220V1

Description
Rocker Switch, On-off-on, 8A, 24VDC, Screw Terminal, Rocker Actuator, Panel Mount
CategoryMechanical and electronic products    switch   
File Size333KB,8 Pages
ManufacturerAPEM
Download Datasheet Parametric View All

2639LHA1/43301L220V1 Overview

Rocker Switch, On-off-on, 8A, 24VDC, Screw Terminal, Rocker Actuator, Panel Mount

2639LHA1/43301L220V1 Parametric

Parameter NameAttribute value
MakerAPEM
Reach Compliance Codecompliant
Actuator colorGREEN
Actuator length0.354 inch
Actuator materialPOLYAMIDE
Actuator typeROCKER
Other features220VAC FLUORESCENT LAMP
body width24.9936 mm
body height16.9926 mm
Body length or diameter32.004 mm
center contact materialSILVER
Maximum contact current (DC)8 A
Contact (DC) maximum rated R load8A@24VDC
Contact functionON-OFF-ON
Contact resistance0.01 mΩ
Maximum contact voltage (DC)24 V
Dielectric withstand voltage2500VRMS V
Electrical life10000 Cycle(s)
End contact materialSILVER
Shell materialPOLYAMIDE
Insulation resistance1000000000 Ω
Manufacturer's serial number2600
Installation featuresPANEL MOUNT
Maximum operating temperature85 °C
Minimum operating temperature-20 °C
surface mountNO
Switch typeROCKER SWITCH
Terminal length0.437 inch
Termination typeSCREW
2600 series
Power rocker switches
Distinctive features and specifications
Three rocker shapes : plain, V-shaped or concave
Various rocker colours
Frame with protection guard on 2600LP models
Illuminated or non-illuminated
UL, CSA, VDE and NF (EN 61058-1) approved
ELECTRICAL SPECIFICATIONS
• Max. current/voltage rating with resistive load and approved ratings : see table below.
• Initial contact resistance : 10mΩ max.
• Insulation resistance : 1.000 MΩ min. at 500VDC
• Dielectric strength : 2.500 Vrms 50 Hz min. between terminals
3.000 Vrms 50 Hz min. between terminals and metal panel
• Electrical life : 10.000 cycles at full load
APPROVED RATINGS
FUNCTIONS
CSA (double pole)
CSA 22-2
DIRECT CURRENT
NF
EN 61058-1
UL (double pole)
UL 1054
VDE
EN 61058-1
24 VDC
12 VDC
D
ON - OFF
ON - ON
1/6 HP 125VAC
16A 125VAC
16A 250VAC
1/3 HP 250VAC
10A 125VAC
10A 250VAC
1/6 HP 125/250VAC
-
10A 125VAC
10A 250VAC
1/6 HP 250VAC
1/6 HP 125VAC
16A 125VAC
16A 250VAC
1/3 HP 250VAC
10A 125VAC
10A 250VAC
1/6 HP 125/250VAC
-
-
10(4)A 250VAC
T 85/55
-
10A
15A
ON - OFF - ON
ON - ON - ON
OTHERS
L I option
10(4)A 250VAC
-
L I option
10(4)A 250VAC
L I option
10(4)A 250VAC
-
L I option
10(4)A 250VAC
8A
5A
8A
10A
8A
10A
MATERIALS
GENERAL SPECIFICATIONS
• Case : melamine/polyester
• Frame : polyamide
• Actuator : polyamide
• Contacts :
A
: silver
C
: copper, silver plated
• Panel thickness : 0,8 mm to 4 mm (.031 to .157)
• Operating temperature :
- silver contacts (A) : -20°C to +85°C
- silver plated contacts (C) : -10°C to +55°C
AGENCY APPROVALS
EN 61058-1
EN 61058-1
Availability
: consult factory for details of approved models.
Marking
: approved models are standard marked.
APEM
www.apem.com
D-45
EEWORLD University - Keysight Two-Minute Mentor Season 2
Keysight Two-Minute Mentor Season 2 : https://training.eeworld.com.cn/course/4658Introduce the basic components and basic knowledge of circuits...
老白菜 Test/Measurement
FAQ_ S2LP FEC Rules
Author: Joshua Zhu, ST engineer Click to download the pdf document:Keywords: S2-LP, sub 1GHZProblem: Customers use S2-lp to develop their products. Now they can enable FEC to communicate between two S...
nmg ST - Low Power RF
Instructions for help with graduation project!
[i=s]This post was last edited by paulhyde on 2014-9-15 09:08[/i] [size=4]First of all, some of the following may not sound good, please forgive me! First, please be more specific when you post your g...
open82977352 Electronics Design Contest
TI CC2640R2F SDK structure and some concept analysis
1. OverviewCC2640R2F is a BLE single SOC solution. TI's SDK divides the project into two parts: application program (APP) and protocol stack (Stack).2. Protocol stackThe protocol stack includes: host ...
Jacktang Wireless Connectivity
Automatic Test System Based on Ethernet Technology
The establishment of an automatic test system often includes one or more instruments, a host computer and test software, a test fixture, and a system bus. The system bus is like a central nervous syst...
wdxyx Industrial Control Electronics
2008 4th International Indian Electronic Components Exhibition
[b][size=22pt]2008[/size][/b][b][font=黑体][size=22pt]The 4th International Indian Electronic Components Exhibition[/size][/font][/b][b][size=22pt][/size][/b] [b][size=22pt]ELOMP INDIA 2008[/size][/b] [...
huihua Energy Infrastructure?

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2294  2087  888  1409  1354  47  43  18  29  28 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号