EEWORLDEEWORLDEEWORLD

Part Number

Search

2200JGG5002A3EB

Description
Strain Guage Sensor, Gage, 0Psi Min, 500Psi Max, 0.15%, 0.50-5.50V, Cylindrical
CategoryThe sensor    Sensor/transducer   
File Size507KB,4 Pages
ManufacturerGems Sensors & Controls
Download Datasheet Parametric View All

2200JGG5002A3EB Overview

Strain Guage Sensor, Gage, 0Psi Min, 500Psi Max, 0.15%, 0.50-5.50V, Cylindrical

2200JGG5002A3EB Parametric

Parameter NameAttribute value
Is it Rohs certified?incompatible
Reach Compliance Codeunknow
Maximum accuracy(%)0.15%
shellSTAINLESS STEEL
Nominal offset0.50V
Maximum operating temperature125 °C
Minimum operating temperature-40 °C
Output range0.50-5.50V
Output typeANALOG VOLTAGE
Package Shape/FormCYLINDRICAL
port type1/4 NPT
Maximum pressure range500 Psi
Minimum pressure range
Pressure sensing modeGAGE
Sensor/Transducer TypePRESSURE SENSOR,STRAIN GUAGE
Maximum supply voltage35 V
Minimum supply voltage1.5 V
Termination typeDIN 9.4MM W/MATE
Base Number Matches1
Several suggestions for new piping engineers
I have been engaged in piping work for three years. Time flies by like flowing water. I started this job after I graduated from university three years ago. At that time, I was like a headless fly and ...
proudjeff PCB Design
Cross-clock domain
How to synchronize the signal generated by the 300KHz clock domain to the 10MHz clock domain? Because one cycle of 300KHz includes 33 cycles of 10MHz, but I want to generate only one valid-syn signal ...
573481734 FPGA/CPLD
Demodulation of AM Waves
I would like to ask you a question, what kind of circuit is suitable for demodulating 70MHz AM waves?...
aabbcc Analog electronics
Magnetic beads
What are magnetic beads? What is their function?...
zhonghuadianzie PCB Design
I originally used AVRMEGA64 and now I want to change the chip. If I use STM8
I originally used AVR MEGA64 and now I want to change the chip. If I use STM8, can someone recommend a similar model? Thank you!...
Nechi stm32/stm8
How to judge the occurrence of self-excited oscillation in question D of 2015
How to judge whether a circuit has self-excitation? Should I adjust the DDS amplitude to 0, short-circuit the DDS signal probe, or unplug the probe and leave nothing connected? ?...
loadinghl Electronics Design Contest

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1115  2171  139  1267  2287  23  44  3  26  47 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号