EEWORLDEEWORLDEEWORLD

Part Number

Search

3100-15T1999

Description
TE CONNECTIVITY / PRODUCTS UNLIMITED - 3100-20U18999CL - CONTACTOR DPST-NO-DM; 240VAC; 40A; PANEL
Categorysemiconductor    Analog mixed-signal IC   
File Size158KB,2 Pages
ManufacturerMACOM
Websitehttp://www.macom.com
Download Datasheet View All

3100-15T1999 Online Shopping

Suppliers Part Number Price MOQ In stock  
3100-15T1999 - - View Buy Now

3100-15T1999 Overview

TE CONNECTIVITY / PRODUCTS UNLIMITED - 3100-20U18999CL - CONTACTOR DPST-NO-DM; 240VAC; 40A; PANEL

Catalog 1308242
Issued 3-03
PRODUCTS UNLIMITED
Model 96 - 3100
series
Definite Purpose Contactor
1- or 2-pole, 20-40 FLA
AC Coil
File E75492
File EN60947-4-1:1991
IEC 947-4-1
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that users also seek out the pertinent approvals files of
the agencies/laboratories and review them to ensure the product meets the
requirements for a given application.
Features
• Robust 1- and 2-pole contactors.
• Shunt available on 1-pole models.
• Convenient mounting plate.
Environmental Data
Temperature Range:
Storage and Operating: -40°C – +65°C.
Flammability:
UL 94-HB housing.
Mechanical Data
Contact Data @ 25°C
Arrangements:
1 Form X (SPST-NO-DM) with or without shunt and
2 Form X (DPST-NO-DM).
Maximum Ratings:
See Contact Ratings Table.
Material:
Silver Cadmium Oxide.
Contact Termination:
20, 25, 30 FLA Models
Type:
#10-32 Screw with quad 0.250” (6.35 mm) quick connects.
Wire Size:
16-8 AWG (Stranding must be split for 8 AWG wire.)
Tightening Torque:
25 in.-lbs.
40 FLA Models
Type:
Box Lug with dual 0.250” (6.35 mm) quick connects.
Wire Size:
14-4 Cu/Al AWG
Tightening Torque:
40 in.-lbs.
Coil Termination:
Dual 0.250” (6.35 mm) quick connects.
Arc Cover:
Optional on 20-30 FLA models, standard on 40 FLA models.
Weight:
One Pole Types: 8 oz. (227 g) approximately.
Two Pole Types: 9.6 oz. (273 g) approximately
Coil Data @ 25°C
Voltage:
24 - 277 VAC, 50/60 Hz. See Coil Data Table below.
Insulation Class:
UL Class B (130°C).
Duty Cycle:
Continuous.
Contact Ratings
Full
Load
Amps
20
Number
of
Poles
2
Line
Voltage
240/277
480
600
240/277
480
600
240/277
480
600
240/277
480
600
240/277
480
600
240/277
480
600
240/277
480
600
Locked
Rotor
Amps
120
100
80
150
50
40
150
125
100
150
75
50
150
125
100
240
200
160
240
200
160
Resistive
Amps
Rating
30
30
30
30
30
30
35
35
35
40
40
40
40
40
40
50
50
50
50
50
50
Maximum Horsepower
Voltage
Single
Phase
120
2
240
3
120
240
120
240
120
240
120
240
120
240
120
240
1
2
2
3
1
2
2
3
2
3
2
3
25
1
25
2
30
1
30
2
40
1
40
2
Coil Data
Nominal Coil Voltage
Maximum Pickup Volts
Drop-Out Volts Range
Nominal Inrush VA @ 50 Hz
Nominal Inrush VA @ 60 Hz
Nominal Sealed VA @ 50 Hz
Nominal Sealed VA @ 60 Hz
Nominal DC Resistance - Ohms
Dimensions are shown for
24
18
6 - 15
22.5
20
7
5.25
16.5
1-Pole Models
120
88
20 - 70
22.5
20
7
5.25
420
208/240
177
40 - 140
22.5
20
7
5.25
1850
277
221
50 - 165
22.5
20
7
5.25
2650
24
18
6 - 15
37
35
8
7
11
2-Pole Models
120
88
20 - 70
37
35
8
7
250
208/240
177
40 - 140
37
35
8
7
1000
277
221
50 - 165
37
35
8
7
1600
830
reference purposes only.
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Specifications and availability
subject to change.
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
Ask: Change the format (length) of the data sent by the serial port
Hello everyone, the serial port program I am debugging now has no problem in sending and receiving simple data. For example, if I send "A", if it is displayed in ASCII code, I can receive "A" at the o...
sunghx Embedded System
Design of automatic assembly line workpiece counting
Using a single-chip microcomputer and a sensor, the workpiece is conveyed in a single direction on the automatic belt conveyor. When the workpiece passes through the detection area, the sensor detects...
122866320 MCU
Some issues with VxWorks development on 80C186EB!
I would like to ask if I want to use VxWORKS to develop on 80C186, should I use VxWORKS FOR PENTIUM? In addition, I have spent a lot of time searching on the Internet but I can't find the BSP for 80C1...
louiswujg Real-time operating system RTOS
[Based on KW41Z intelligent parking management system] Second post: KW41Z performance learning
[b][color=#5E7384]This content is originally created by [size=3]陌路绝途[/size], a netizen of EEWORLD forum. If you need to reprint or use it for commercial purposes, you must obtain the author's consent ...
陌路绝途 NXP MCU
Stepper motor drive problem
Well, I made a ln298 and ln297 to drive a stepper motor, but when the clock goes into the 18th pin of my ln297, for example, a 40hz square wave, the a, b, c, d four-phase output of the ln297 is not a ...
luowei100 51mcu

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1654  293  2632  92  425  34  6  53  2  9 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号