CAT6+ Patch Cord, Bonded-Pair, 4 Pair, 24 AWG Solid, CMR, T568A/B-T568A/B, White, 3 ft. (0.9 m).
Usage (Overall)
Suitable Applications:
Related Parts:
IBDN System 4800, IBDN System 2400,TIA Category 6, ISO Class E, 1000BASE-T
CAT6+ Modular Jacks, CAT6+ Patch Panels
Multi Conductor
Physical Characteristics
Conductor
AWG:
# Pairs AWG Stranding Conductor Material
4
24
Solid
BC - Bare Copper
Insulation
Insulation Material:
Insulation Material
PO - Polyolefin
Outer Jacket
Outer Jacket Material:
Outer Jacket Material
PVC - Polyvinyl Chloride
Outer Jacket Color Code Chart:
Color
White
Overall Cabling
Overall Cabling Fillers:
Cross Web
Overall Diameter
Overall Nominal Diameter:
Individual Cable Diameter:
0.238 in.
0.250 in.
Physical Characteristics (Connectivity)
Materials
Materials:
Description
Plug
Boot
Type
RJ45
Material
Polycarbonate
Rubber
Front Connection Blades Phosphor Bronze with 50u inch Gold over Nickel Plating
Color
Boot Color:
Translucent
Wiring Scheme
Wiring Scheme:
T568A/B-T568A/B
Weight
Weight:
0.060 lbs.
Packaging
Packaging:
Individually packaged in a clear plastic bag.
Mechanical Characteristics (Connectivity)
Plug / Jack Compatibility:
Termination Interface:
Termination Connection
RJ45
Durabilities
Mated Connection 750 Cycles
RJ45
Page 1 of 3
07-23-2014
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
C601109003 Cable Assemblies - CAT6+ Modular Cord
Storage Temperature Range:
Installation Temperature Range:
Operating Temperature Range:
Max. Recommended Pull Tension:
Min. Bend Radius (Overall Cable):
-40°C To +70°C
-10°C To +60°C
-10°C To +60°C
25 lbs.
1.040 in.
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
UL Rating:
Other Standards:
EU Directive 2002/95/EC (RoHS):
EU RoHS Compliance Date (mm/dd/yyyy):
MII Order #39 (China RoHS):
Telecommunications Standards:
Safety Listing:
Riser
FCC Part 68, Subpart F, IEC 60603-7
Yes
01/01/2006
EUP 50
Category 6 - TIA 568.C.2, ISO/IEC 11801:2002 Ed.2
ACA, Bi-national Standard Listed
Suitability
Suitability - Indoor:
Yes
Transmission Characteristics (Connectivity)
Performance Table 1:
Max.
Min.
Min
Min.
Min.
Frequency Max.
Insertion Loss Insertion Loss PSNEXT PSNEXT
PSACRF PSACRF
(MHz)
TIA* (dB)
Belden (dB)
TIA* (dB) Belden (dB) TIA* (dB) Belden (dB)
1.000
4.000
8.000
10.000
16.000
20.000
25.000
31.250
62.500
100.000
200.000
250.000
300.000
2.400
4.500
6.400
7.100
9.100
10.200
11.400
12.800
18.500
23.800
34.800
39.400
2.000
3.700
5.200
5.900
7.400
8.300
9.300
10.400
14.900
19.000
27.500
31.000
34.200
72.300
63.300
58.800
57.300
54.200
52.800
51.300
49.900
45.400
42.300
37.800
36.300
73.300
64.300
61.300
59.800
56.600
55.100
53.500
52.000
47.100
43.800
38.900
37.300
36.100
64.800
52.800
46.700
44.800
40.700
38.800
36.800
34.900
28.900
24.800
18.800
16.800
67.800
55.800
49.700
47.800
43.700
41.800
39.800
37.900
31.900
27.800
21.800
19.800
18.300
100 Meter Cable Specifications - * TIA-EIA-568-C.2 Category 6 Standard -------- PSACRF is formally
PSELFEXT
Performance Table - Footnote:
Performance Table 2:
Min.
Min.
Min.
Min.
Frequency (MHz) Return Loss Return Loss Balanced TCL Balanced TCL
TIA* (dB)
Belden (dB) TIA* (dB)
Belden (dB)
1.000
4.000
8.000
10.000
16.000
20.000
25.000
31.250
62.500
100.000
200.000
250.000
300.000
Dielectric Strength:
Current Rating:
Insulation Resistance:
Max. Contact Resistance:
20.000
23.000
24.500
25.000
25.000
25.000
24.200
23.300
20.700
19.000
16.400
15.600
20.000
23.000
24.500
25.000
25.000
25.000
24.300
23.600
21.500
20.800
18.700
18.000
17.500
1,000 V RMS @ 60 Hz for 1 minute
1.500 A
500 M-Ohm Minimum
20 m-Ohm
40.000
40.000
40.000
40.000
38.000
37.000
36.000
35.100
32.000
30.000
27.000
26.000
40.000
40.000
40.000
40.000
38.000
37.000
36.000
35.100
32.000
30.000
27.000
26.000
Notes (Overall)
Notes:
C601109003 is subdivided as following C6-01-1-09-003 C6 stands for performance, 01 stands for cable type, 1 stands for termination type, 09 stands for color, 003stands
Page 2 of 3
07-23-2014
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
C601109003 Cable Assemblies - CAT6+ Modular Cord
Notes:
C601109003 is subdivided as following C6-01-1-09-003 C6 stands for performance, 01 stands for cable type, 1 stands for termination type, 09 stands for color, 003stands
for length Use last 3 digits of the code to specify length in feet - 001-015 ft in increments of 1 ft than 20 ft or 25 ft
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to
change without notice, and the listing of such information and specifications does not ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for
any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether
in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities
and in our Distributor’s inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is
correct to the best of Belden’s knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the
safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification.
Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the
I want to make a reading and writing program for AT24C64A written in VC. If anyone has the information, please provide it to me. The ones on the Internet are all in assembly and C. Now I need VC....
How to defend the switch from DDoS attack and robot dog virus? I have searched a lot of information on the Internet, but there is no good way. I was assigned this task when I just joined the company, ...
I made two versions of the ZIGBEE core board. The first version can burn the program normally. The second version only changed the position of some components and modified the wiring. However, the sec...
Emergency hand-held lamps powered by 6V maintenance-free batteries are widely used in rural areas. The charger used is a transformer step-down and single diode half-wave rectifier, and the charging...[Details]
The Portable Digital Data Acquisition System (PDDAS) uses LabVIEW Real-Time and PXI to control the wind tunnel test and record air pressure data from 128 different channels.
"The LabVIEW Real-...[Details]
There are three types of mobile TV: one is based on analog TV broadcasting network, another is based on mobile communication network, and the other is based on digital broadcasting network. The f...[Details]
This paper establishes a fuel cell engine test platform based on the NI integrated hardware and software environment. This platform can realize the test and control of fuel cell engines and their a...[Details]
The data collector of the automatic weather station is generally designed based on a single-chip microcomputer or a PC/104 bus controller. It has the characteristics of good compatibility with PC, low...[Details]
1. Introduction
With the gradual automation and modernization of industrial control systems, fieldbus control systems have received more and more attention and application. CAN bus is currentl...[Details]
1. Introduction to CIF Board
Fieldbus integration based on PC system
Whether it is a master or a slave, fieldbus has won unanimous praise in the field of PC-based automation. For more...[Details]
1 Introduction
The Third Steel Plant of Jigang Group is a key investment project of Jigang Group during the "15th Five-Year Plan". It has introduced first-class domestic and foreign advanced eq...[Details]
Toyohashi University of Technology demonstrated electric field coupled wireless power supply technology using life-size car tires and roads at the wireless technology exhibition "Wireless Technolog...[Details]
1. When the slip speed regulating motor is undergoing frequency conversion and energy saving transformation, the original excitation box (referred to as the speed regulating box) and the original s...[Details]
1 Introduction
Ultrasound refers to elastic vibration with a frequency higher than the audible frequency limit (i.e., in the frequency band above 20 kHz). The propagation process of this vib...[Details]
The DisplayPort interface standard is approved by the Video Electronics Standards Association (VESA) to provide an open, scalable standard for the entire industry. The development of DisplayPort ca...[Details]
The above is to use MB1404 as a stereo composite signal transmitter. You can use the internal high-frequency amplifier and oscillator or not! According to my experience, I still recommend beginners...[Details]
1 Embedded Systems
Embedded System refers to a collection of computer hardware and software with specific functions or purposes, which is divided into embedded software system and embe...[Details]
store
To prevent moisture, LEDs should be stored in a dry and ventilated environment with a storage temperature of -40°C to +100°C and a relative humidity below 85%.
The LED should be use...[Details]