EEWORLDEEWORLDEEWORLD

Part Number

Search

DTA-060A-01Y170

Description
To 60 Watts Single Output AC/DC Desktop Power Supply
File Size48KB,2 Pages
ManufacturerWall Industries,Inc.
Websitehttps://www.wallindustries.com/
Download Datasheet View All

DTA-060A-01Y170 Overview

To 60 Watts Single Output AC/DC Desktop Power Supply

Rev B
DTA-060A Series
To 60 Watts
Single Output
AC/DC Desktop Power Supply
FEATURES
Single Output
High Reliability
Input: 90~264VAC
100% Hi-Pot Tested
100% Burn-In Tested
Total Power: 40~60 Watts
AC Input: IEC-320-C14 Inlet
Safety Approvals, EMC Compliance
Dimensions: 5.20 x 2.72 x 1.57 Inches
Over Voltage, Over Load, and Short Circuit Protected
DESCRIPTION
The DTA-060A series offers up to 60 Watts of power in a single output universal input AC/DC desktop power supply. Output
voltages are available from 9VDC to 24VDC. This series also has an IEC-320-C14 AC inlet connector and has over voltage,
over load, and short circuit protection. All units are 100% burn-in and hi-pot tested and have safety approvals and EMC
compliance.
SPECIFICATIONS:
DTA-060A Series
All specifications apply @ ±25°C ambient unless otherwise noted
INPUT SPECIFICATIONS
Input Voltage Range ............................. 90 ~ 264 VAC (full range)
Input Frequency ............................................................. 47 - 63Hz
Input Current (rms)................. 2A @ 90VAC; 1A @ 264VAC max.
ENVIRONMENTAL SPECIFICATIONS
Operating Temperature ............................................. 0°C to +40°C
Storage Temperature............................................... -10°C to+70°C
Humidity........................................................................20% ~ 90%
MTBF ................ >80,000 hrs at FL and 25°C ambient temperature
OUTPUT SPECIFICATIONS
Output Current ................................................................ see table
Output Voltage ................................................................ see table
Output Regulation ................................................................ 3~5%
Maximum Power ............................................................. see table
PHYSICAL SPECIFICATIONS
Weight ....................................................................................12 oz
Dimensions (L x W x H) ...........................5.20 x 2.72 x 1.57 inches
132 x 69 x 40 mm
AC Inlet ...................................................................... IEC-320-C14
Ripple/Noise (20 MHz BW) ...................................................... 1%
Hold Up Time .................... >10ms typical at full load and 115VAC
SAFETY & EMI
Safety Standards ...........................................................UL60950-1
...................................................................CSA C22.2-No.60950-1
.............................................................................. TUV EN60950-1
.............................................................................. CB IEC 60950-1
EMI Standards ............................................................FCC Class B
............................................................................ CISPR22 Class B
........................................................................... EN 55022 Class B
................................................................................................... CE
PROTECTION
Short Circuit Protection ........................................... Auto-recovery
Over Load Protection .............................................. Auto-recovery
Over Voltage Protection .......................................... Auto-recovery
GENERAL SPECIFICATIONS
Efficiency....................................... >75% @ full load and 115VAC
Due to advances in technology, specifications subject to change without notice
Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833
603-778-2300 www.wallindustries.com Fax 603-778-9797
Gas sensor data collection
I have summarized some of the information in the forum, hoping it can be helpful. Current research trends and development directions of new gas sensors [url=https://bbs.eeworld.com.cn/thread-2286-1-45...
soso Mobile and portable
Interruption time
If the interrupt program is too long, the running time is 2ms, and the timing time is 1ms, what will happen when the second timing time expires?...
zzbaizhi Microcontroller MCU
Here are some 430 codes that I have collected and collected! They are not often seen!
0) LCD\Debug\Exe\test.d431) Serial communication (send a byte)\Backup of Serial communication (send a byte).ewp2) Output MCLK clock signal\Debug\Exe\test.d433) Watchdog timer\Debug\Exe\test.d434) Time...
wuyanyanke Microcontroller MCU
I fell into a trap of TMC
A certain TMC model stepper driver has a stepper + encoder. The encoder is connected to the driver. There are not many places in the chip to operate the encoder (not too few either). It is connected t...
freebsder Motor Drive Control(Motor Control)
2018 The 14th China Zhengzhou International Machine Tool Exhibition
[color=#000][font=Arial, Verdana, sans-serif][size=14px] [/size][/font][/color][p=null, 2, center][color=rgb(0, 0, 0)][font=Arial, Verdana, sans-serif][size=14px][b]201[/b][b]8[/b][b]The 1st[/b][b]4th...
zzhaiming Robotics Development
Share a wireless Modbus communication routine of Inovance PLC with source code and instructions, download at the required speed
I worked on the wireless Modbus communication routine of Inovance PLC late at night and I will share it with you soon...
2020da Test/Measurement

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 258  1725  393  1075  88  6  35  8  22  2 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号