EEWORLDEEWORLDEEWORLD

Part Number

Search

DTIPU45-103

Description
Up to 50 Watts Single, Dual, & Triple Outputs AC/DC Desktop Power Supply
File Size187KB,3 Pages
ManufacturerWall Industries,Inc.
Websitehttps://www.wallindustries.com/
Download Datasheet View All

DTIPU45-103 Overview

Up to 50 Watts Single, Dual, & Triple Outputs AC/DC Desktop Power Supply

Rev. A
DTIPU45 Series
Up to 50 Watts
Single, Dual, & Triple Outputs
AC/DC Desktop Power Supply
FEATURES
Splash Proof
Scanners
Class I Insulation
LCD Monitors
Two Year Warranty
Thermal Printers
IEC-320-C14 Input Inlet
Humidity Temperature Meters
Optional Output Connectors
Single, Dual, and Triple Outputs
Over Voltage Protection (Crowbar Design)
-20°C~+70°C Operating Temperature Range
Wide Input Voltage Range: 90~264VAC, 47~63Hz
Input Surge Current, Over Voltage, and Over Load Protection
APPLICATIONS
DESCRIPTION
The DTIPU45 series of AC/DC switching mode power supplies provide up to 50 watts of continuous output power. Models have a universal
input range and are available with single, dual, or triple outputs. Some features include -20°C ~ +70°C operating temperature and input
surge current, over voltage, and over load protection. All supplies are UL94V-1 compliant and include an IEC-320-C14 input for worldwide
applications. These supplies meet FCC Part-15 class B and CISPR-22 class B emission limits and are designed to comply with UL/c-UL
(UL 60950-1), TUV/GS (EN 60950-1), and new CE requirements. All units are 100% burn-in tested.
SPECIFICATIONS:
DTIPU45 Series
All specifications are based on 25°C, Nominal Input Voltage, and Maximum Output Current unless otherwise noted.
We reserve the right to change specifications based on technological advances.
SPECIFICATION
INPUT (V
in
)
Input Voltage
Input Frequency
Input Current (Low Line)
Input Current (High Line)
Inrush Current (Low Line)
Inrush Current (High Line)
Safety Ground Leakage Current
Start-Up Time
OUTPUT (V
o
)
Output Voltage Range
Load Regulation
Line Regulation
Output Power Range
Output Current Range
*Ripple
& Noise (peak to peak)
Transient Response
Hold-Up Time
PROTECTION
Over Voltage Protection
Over Current Protection
GENERAL
Efficiency
Dielectric Withstanding Voltage
For Primary to Secondary
Dielectric Withstanding Voltage
For Primary to Ground
Isolation Resistance
ENVIRONMENTAL
Operating Temperature
Storage Temperature
Relative Humidity
Temperature Coefficient
MTBF
PHYSICAL
Weight
Dimensions
Warranty
SAFETY
EMI Requirements for CISPR-22
EMI Requirements for FCC PART-15
TEST CONDITIONS
Min
90
47
Nom
Max
264
63
1.35
0.8
15
30
0.75
2
Unit
VAC
Hz
A
A
A
A
mA
s
%
%
W
%
ms
ms
%
%
%
VDC
VDC
MΩ
Io = Full Load, Vin = 115VAC
Io = Full Load, Vin = 230VAC
Io = Full Load, 25°C, Cool Start, Vin = 115VAC
Io = Full Load, 25°C, Cool Start, Vin = 230VAC
Io = Full Load, Vin = 240VAC
Io = Full Load, Vin = 100VAC
Vin = 230VAC
Io = Full Load
Vin = 90 to 264VAC
Full Load, Vin = 90VAC
Io = Full Load to Half Load, Vin = 100VAC
Io = Full Load, Vin = 110VAC
0.3
12
26
0.5
1
0
See Rating Chart
3
15
0.5
1
50
See Rating Chart
0.5
1
4
132
150
83
88
16
112
110
Io = Full Load, Vin = 230VAC
Primary to Secondary
Primary to Ground
Test Voltage = 500VDC
Derate linearly from 100% Load at 40°C to 50% load at 70°C
All Outputs
Operating temperature at 25°C, Calculated per MIL-HDBK-217F
75
4242
2121
50
-20
-40
5
-0.04
70
85
95
+0.04
100,000 hours
°C
°C
%
%/°C
Approximately 535 ~ 560 grams
5.75(L) x 2.99(W) x 1.69(H) inches
146.0(L) x 76.0(W) x 43.0(H) mm
2 years
Vin = 220VAC
Vin = 110VAC
B
B
Class
Class
*Note: The Ripple & Noise for output voltages under 3.3VDC is 2% max.
Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833
603-778-2300 www.wallindustries.com Fax 603-778-9797
A very simple question, to construct an adder and a timer
Suddenly I had an idea, I want to make an accessory for my car, to estimate how long it can run. The main idea is this, a sensor measures the current fuel level (night face height or directly read the...
kangxin Embedded System
Samsung announced that it has developed a graphene battery that can be fully charged in 12 minutes. What product do you most want graphene batteries to be used in first?
Samsung Electronics has announced that it has developed graphene battery technology that increases battery capacity while boosting charging speeds to five times the current standard, The Korea Herald ...
eric_wang Power technology
Bluetooth 4.0 SensorTag Active UsbDongle board welding successful
The signal is pretty good....
littleshrimp Wireless Connectivity
Doubts in 2440init.s
;//copy program from nandflash to sdram ;============================================================ nand_boot_beg bl ClearSdram mov r5, #NFCONF ;set timing value ldr r0, =(7<<12)|(7<<8)|(7<<4) str r...
bonjovi2003 Embedded System
Embedded operating system, when tasks are allowed to have the same priority, how to handle event waiting? (Add more points if the score is not enough)
When adding tasks of the same priority, the event waiting table cannot simply hang the task in the event waiting table, because when multiple tasks of the same priority are waiting, it is impossible t...
pinkgerbera Embedded System
Friends, please remember not to touch the SPI routine (register-based) in the MSP342 routine, otherwise, tears will flow immediately!
[i=s]This post was last edited by minjiang on 2015-10-24 10:33[/i] When I was making the eUSC module, I broke 3 development boards in a row. I cried so hard that I wanted to warn everyone! The SPI rou...
minjiang Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 454  2160  1767  2564  2013  10  44  36  52  41 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号