CAPACITOR, METALLIZED FILM, POLYPROPYLENE, 20uF, CHASSIS MOUNT, CAN, ROHS COMPLIANT
CategoryPassive components    capacitor   
File Size742KB,5 Pages
ManufacturerCDE [ CORNELL DUBILIER ELECTRONICS ]
Environmental Compliance  
Download Datasheet Parametric View All

SFP44S20K288E-F Overview

CAPACITOR, METALLIZED FILM, POLYPROPYLENE, 20uF, CHASSIS MOUNT, CAN, ROHS COMPLIANT

SFP44S20K288E-F Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerCDE [ CORNELL DUBILIER ELECTRONICS ]
package instruction,
Reach Compliance Codecompliant
ECCN codeEAR99
Other featuresRATED AC VOLTAGE (V): 440
capacitance20 µF
Capacitor typeFILM CAPACITOR
diameter47.498 mm
dielectric materialsPOLYPROPYLENE
JESD-609 codee3
length73.152 mm
Manufacturer's serial numberSF
Installation featuresCHASSIS MOUNT
negative tolerance10%
Number of terminals2
Maximum operating temperature70 °C
Minimum operating temperature-40 °C
Package shapeCYLINDRICAL PACKAGE
Package formQuick Connect
positive tolerance10%
Rated (AC) voltage (URac)440 V
seriesSF
surface mountNO
Terminal surfaceTin (Sn)
Terminal shapeBINDING POST
Type SF
Motor-Run and Power Supply Capacitors
Oil Filled/Impregnated, AC Rated, Metallized Polypropylene Capacitors
Type SF, AC rated metallized polypropylene capacitors pro-
vide starting torque and power factor correction for split
phase motors typically used in refrigeration and air condi-
tioning motor-run applications. Type SF also may be used
to provide noise suppression, voltage regulation and line
current reduction in power supply applications.
Highlights
Specifications
Self healing
Fault Current Protection up to 10,000 amps AFC
Low energy consumption
4 - tine, 1/4" quick connect lug terminals are standard
Meets EIA Standard EIA-456-A
UL recognized File Number E71645
CSA File Number 223507
Capacitance Range:
Voltage Range:
Capacitance Tolerance:
Temperature Range:
Dissipation Factor:
5.0 µF to 120.0 µF
240 Vac to 660 Vac
±10% standard, ± 6% and ±3% available
–40 ºC to 70 ºC standard, 90 º C available
<0.1%
Service Life Objective
The service life objective for this series is 60,000 hours of
operating life with a 94% survival rate when operated at full
voltage, 60 Hz, and rated ambient temperature. AC
capacitors are frequently used at voltages and ambient
temperatures other than rated conditions. Service life may
be estimated under specific conditions of temperature and
voltage by using the curves as shown
below and
to the right.
Capacitance vs. Temperature
The Capacitance vs. Temperature curve may be used to
determine the capacitance change as a function of
temperature. capacitance varies by no more than ±3 % over
the operating temperature range.
Capacitance vs. Temperature
Capacitance Change %
4
2
0
–2
–4
–6
–40
–20
0
20
40
60
80 100
Life vs. Temperature
100000
10000
1000
100
10
0
25
50
75
100
125
% of Rated Life
Temperature °C
Life vs. Voltage
% of Rated Life
% of Rated Temperature
1.002
% of Rated Voltage
Cornell Dubilier
1605 E. Rodney French Blvd.
New Bedford, MA 02744
Phone: (508)996-8564
Fax: (508)996-3830
www.cde.com
ZTE's turnaround in the 4G era is difficult
[color=#333333][font=Arial, Helvetica, sans-serif, 宋体]After its efforts in 2013, ZTE has received a "report card" that is both good and bad. [/font][/color] [p=22, null, left][color=rgb(51, 51, 51)][f...
azhiking Talking
Knowing the complement code, how to calculate the original code?
The conversion result given by ADS1220 is in the form of two's complement. In order to calculate the size of the input analog quantity, it needs to be converted to the original code. Question: Knowing...
yhye2world Integrated technical exchanges
Share the example program using STemWin control
[i=s]This post was last edited by 1428662475 on 2016-11-22 19:32[/i] [font=微软雅黑][size=4]First let's take a look at the main control. The WB-RedDragon429 development board is a learning board based on ...
1428662475 stm32/stm8
Has anyone used the PCM1860 AD? How many channels does it have?
[font=微软雅黑][size=5]Has anyone used the PCM1860 AD? How many channels does it have? ? Please help me. [/size][/font] eeworldpostqq...
蓝猫淘气 ADI Reference Circuit
Ask for advice: Errors loading SDK(S)
After installing the BSP package, Errors loading SDK(S) appears when opening it: E:E:\WINCE600\OSDesigns\S3C6410_DEMO\S3C6410_DEMO\SDKs\SDK1\SDK1.sdkcfg does not exist How can I solve this problem? I ...
renkes Embedded System
ORCAD reports an error when exporting the netlist. I want to ask why
[i=s]This post was last edited by haha丶 on 2022-5-24 20:39[/i]ORCAD reports an error when exporting the netlist. I want to ask why #1 ERROR(ORCAP-36035): Multiple pin 12's which have different nets co...
haha丶 PCB Design

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1619  2406  2461  73  890  33  49  50  2  18 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号