The 1623 ITU G.695 compliant O-Band DWDM forward path DFB laser
components are designed for both broadcast and narrowcast analog applications.
The highly linear, OC-48 pinout compatible components feature options for up to
14 dBm of minimum optical output power with superior distortion performance
over an enhanced temperature range of -40C to +85C.
Performance Highlights
Parameter
Min
1317.90
1321.10
1322.80
1323.97
1325.30
Wavelength
1326.90
1325.60
Typical
1318.10
1321.30
1323.00
1324.17
1325.50
1327.10
1325.80
1327.25
1329.20
1330.50
-
-
-
-
-
-
-
-
-
-
-
-
Max
1318.30
1321.50
1323.20
1324.37
1325.70
1327.30
1326.00
1327.45
1329.40
1330.70
7.9
8.9
9.9
11.9
12.9
13.9
-
+85
1002
-
-60
-66
Units
Applications
O-Band DWDM Forward Path
Broadcast and Narrowcast Networks
DWDM Cuts New Fiber Costs
High Optical Splits
nm
Features
OC-48 Pinout Compatible
Telcordia
Compliant
Technologies
TM
468
1327.05
1329.00
1330.30
6
8
9
Optical Output Power
10
12
13
14
Temperature Range
Frequency Range
Carrier to Noise Ratio
Composite Second Order (multiple versions)
Composite Triple Beat (multiple versions)
-40
5
51
-
-
Up to 110 Channel Count
Up to 14 dBm
Wide Temperature Range – Stable even
in Harsh Environments
RoHS Compliant
dBm
C
MHz
dB
dBc
dBc
| REV 2012.06
Information contained herein is deemed reliable and accurate as of the issue date. EMCORE reserves the right to change the design or specification at any time without notice.
1623A/B O-Band DWDM DFB Laser Module
DATASHEET | JUNE 2012
FIBER OPTICS
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute
stress ratings only. Functional operation of the device is not implied at these or any other conditions in excess of those
given in the operational sections of the data sheet. Exposure to absolute maximum ratings for extended periods can
adversely affect device reliability.
Parameter
Operating Temperature Range
Storage Temperature Range
Laser Forward dc Current
Photodiode Reverse Voltage
Laser Reverse Voltage, dc
ESD
TEC Current
Symbol
T
c
T
STG
-
V
RPD
-
-
I
TEC
Condition
Continuous
-
-
-
-
HBM: R = 1500 OHM,
C = 100pF
Continuous
Min
-40
-40
-
-
-
-500
-1.9
Max
+85
85
150
10
1
500
1.9
Unit
°C
°C
mA
V
V
V
A
Electrical/Optical Characteristics
Laser Temperature (TL) = Laser temp set for center WL, IF=IOP, Beginning of Life (BOL)
Parameter
Symbol
Condition
1318.10 nm option
1321.30 nm option
1323.00 nm option
1324.17 nm option
1325.50 nm option
1327.10 nm option
1325.80 nm option
1327.25 nm option
1329.20 nm option
1330.50 nm option
-06 version (4mW)
-08 version (6mW)
-09 version (8mW)
-10 version (10 mW)
-12 version (16 mW)
-13 version (20 mW)
-14 version (25 mW)
-
-
-
I
F
= I
TH
+ 20 and I
TH
+ 60
Varies with power option
V
RM
=5V
T
OP
=25°C
Min
1317.90
1321.10
1322.80
1323.97
1325.30
1326.90
1325.60
1327.05
1329.00
1330.30
6
8
9
10
12
13
14
30
35
-
0.135
-
14
10
9.5
Typ
1318.10
1321.30
1323.00
1324.17
1325.50
1327.10
1325.80
1327.25
1329.20
1330.50
-
-
-
-
-
-
-
-
-
-
-
-
-
-
10
Max
1318.30
1321.50
1323.20
1324.37
1325.70
1327.30
1326.00
1327.45
1329.40
1330.70
7.9
8.9
9.9
11.9
12.9-
13.9
-
-
-
20
-
120
37
200
10.5
Unit
Wavelength
(1)
λ
OPT
nm
Optical Output Power
-
d
Optical Isolation
Side-Mode Suppression Ration
Threshold Current
Slope Efficiency
Operating Current
Laser Temp Range
Monitor PD Responsivity
Thermistor Resistance
ISO
SMSR
I
TH
I
OP
T
L
r
PD
R
TH
dB
dB
mA
mW/mA
mA
°C
μA/mW
KOhm
| REV 2012.06
Information contained herein is deemed reliable and accurate as of the issue date. EMCORE reserves the right to change the design or specification at any time without notice.
1623A/B O-Band DWDM DFB Laser Module
DATASHEET | JUNE 2012
FIBER OPTICS
Electrical/Optical Characteristics
Continued
Parameter
Thermistor Temp. Coefficient
TEC Current
Tracking Error
Fiber Length
Fiber Buffer
Fiber Core/Cladding
Symbol
TC
TH
I
TEC
-
-
-
-
Condition
T
OP
=25°C
-40<T
C
<+85C, I
F
= 100 mA
T
OP
=25
C
May include splice
-
-
Min
-
-1.5
-1
1.0
-
-
Typ
-4.4
-
-
1.5
900
9/125
Max
-
1.6
1
-
-
-
Unit
%/°C
A
dB
M
m
m
(1) Center Wavelength is temperature tuned to be within specs.
In order to prevent reflection-induced distortion, the laser must be connected to an optical cable having a return loff of at
least 55 dB for discrete reflections and 30 dB for distributed reflections.
Outline Drawing (dimensions are in inches & mm)
| REV 2012.06
Information contained herein is deemed reliable and accurate as of the issue date. EMCORE reserves the right to change the design or specification at any time without notice.
1623A/B O-Band DWDM DFB Laser Module
DATASHEET | JUNE 2012
FIBER OPTICS
Electrical Schematics
1
ISOLATOR
10K
ESD
12nH
NC
14
2
(+)
13
3
3.3V
RF CHOKE
22
12
0.01uF
100
LD
(-)
(+)
4
(-)
11
5
(+)
MPD
10
6
(+)
9
CASE
GND
7
(-)
TEC
8
Figure 1. 1623 O-Band DWDM Laser Schematic
Figure 2. 1623 O-Band DWDM Circuit Schematic
Pin Definitions
Pin
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Description
Thermistor
Thermistor
Dc Laser Bias (-)
MPD Anode (-)
MPD Cathode (+)
Thermal Electric Cooler (+)
Thermal Electric Cooler (-)
Case Ground
Case Ground
NC
Laser Common (+)
Laser Modulation (-)
Laser Common (+)
NC
| REV 2012.06
Information contained herein is deemed reliable and accurate as of the issue date. EMCORE reserves the right to change the design or specification at any time without notice.
1623A/B O-Band DWDM DFB Laser Module
DATASHEET | JUNE 2012
FIBER OPTICS
Laser Safety
This product meets the appropriate standard in Title 21 of the Code of Federal Regulations (CFR). FDA/CDRH Class 1 laser
product. This device has been classified with the FDA/CDRH under accession number 0220191.
All Versions of this laser are Class 1 laser product, tested according to IEC 60825-1:2007/EN 60825-1:2007
Single-mode fiber pigtail with SC/APC connectors (standard).
Wavelength = 1.3
m.
Maximum power = 50 mW.
Because of size constraints, laser safety labeling (including an FDA class 1 label) is not affixed to the module, but attached
to the outside of the shipping carton.
Product is not shipped with power supply.
Caution: Use of controls, adjustments and procedures other than those specified herein may result in hazardous
laser radiation exposure.
DANGER
INVISIBLE LASER
RADIATION
AVOID DIRECT EXPOSURE TO BEAM
Wavelength: 1.3
m
Max. Output: 50 mW,
Class 1 Laser Product
DANGER
INVISIBLE LASER RADIATION
IS EMITTED FROM THE END
OF FIBER OR CONNECTOR
Avoid direct exposure to beam
Do not view beam directly with
optical instruments
INVISIBLE LASER RADIATION EMITTED FROM END OF FIBER OR CONNECTOR
Avoid exposure to beam
Class 1 Laser Product IEC-60825-1:20007 Max. Output:50 mw
Wavelength: 1.3
m
| REV 2012.06
Information contained herein is deemed reliable and accurate as of the issue date. EMCORE reserves the right to change the design or specification at any time without notice.
[i=s]This post was last edited by paulhyde on 2014-9-15 09:08[/i] It is mainly about control questions.Shandong Province is more difficult to find questionsYou can go to the official website of the Na...
I found that no matter how I changed the project path and the properties of 28027_RAM_lnk and F28027, these errors would appear... I really don't know what to do......
The NAND disk is K9F2G08 series. The program is modified from the 512K page driver. Is the most basic operation to do page operation? Then the 1 page is divided into 4 sectors, and the 64BYTE SPARE se...
In C++ or C, different development platforms have different main function forms.1.int main();1.1 int indicates that the return value is int. When ending the function, you need to use the return keywor...
1. Several nouns
ABI:
The specifications that an executable file must follow in order to run in a specific execution environment;
Separately generated relocatabl...[Details]
The core of a machine vision system is image acquisition and processing. All information comes from images, and image quality is crucial to the entire vision system. A good image can improve the st...[Details]
EtherCAT (Ethernet for Control Automation Technology) is a real-time industrial fieldbus communication protocol based on an Ethernet-based development framework. EtherCAT is one of the fastest indu...[Details]
A line scan lens is an industrial lens used with line scan cameras. Its imaging principle is to capture the image of the workpiece using a linear sensor and then perform digital signal processing t...[Details]
"Have you set your calendar reminder?"
On August 24, Nvidia Robotics' official account posted a photo of a black gift box on a social media platform, with an attached greeting card sig...[Details]
Whether it is an electric car or an ordinary fuel car, for the vast majority of car buyers, the final cost of use is what they care about most. For fuel cars, how to save fuel is what drivers care ...[Details]
As time goes by, people are increasingly concerned about their own and their families' health. However, existing monitoring devices for individual vital signs have struggled to gain market share du...[Details]
In June 2014, the Ministry of Industry and Information Technology issued 4G FD-LTE licenses to China Unicom and China Telecom. Together with the 4G TD-LTE licenses issued to China Mobile, China Uni...[Details]
UPS stands for Uninterruptible Power Supply, which includes energy storage devices. It is mainly used to provide uninterruptible power supply for devices that require high power stability.
...[Details]
Industrial computers with GPUs leverage powerful parallel processing to build deep learning models to analyze and respond to optical inputs. The systems develop an understanding of visual data to i...[Details]
To improve the lateral active safety of intelligent connected vehicles, the identification and definition of unexpected functional safety scenarios for the EPS (Electronic Steering System) ...[Details]
Analog Devices held a third-quarter fiscal 2025 earnings conference call. Vincent T. Roche, CEO and Chairman of the Board, and Richard C. Puccio, Executive Vice President and Chief Financial Office...[Details]
I believe everyone has heard of memory. If your computer is slow, your experts may recommend upgrading it to a larger capacity. But what exactly is computer memory used for? Why does memory capacit...[Details]
0 Introduction
Portable terminals integrate a computer and display screen into a single device. Due to limited space in portable devices, previous designs often used a single-chip microcompute...[Details]
The power transmission system between a car's engine and drive wheels is called its drivetrain. It ensures the necessary traction and speed under various driving conditions, and coordinates these t...[Details]