EEWORLDEEWORLDEEWORLD

Part Number

Search

55.13.8.006.0021

Description
Electromechanical Relay, 3PDT-CO, MBB, AC/DC Output
CategoryMechanical and electronic products    relay   
File Size3MB,14 Pages
ManufacturerFINDER
Download Datasheet Parametric View All

55.13.8.006.0021 Overview

Electromechanical Relay, 3PDT-CO, MBB, AC/DC Output

55.13.8.006.0021 Parametric

Parameter NameAttribute value
MakerFINDER
Reach Compliance Codecompliant
body width20.7 mm
body height35.8 mm
Body length or diameter27.7 mm
Coil operating voltage (AC)4.8 V
Coil resistance12 Ω
Maximum coil voltage (AC)6.6 V
Nominal coil voltage6 V
Coil/Input Power TypeAC
Contact (AC) maximum rated power R load2500VA@400VAC
Contact (AC) maximum rated R load20A@400VAC
Maximum contact current (AC)20 A
Maximum contact voltage (AC)400 V
Contact/Output Power TypeAC/DC
Dielectric strength between coil and contacts2000 Vrms
Dielectric strength between breaking contacts1000 Vrms
Electrical life200000 Cycle(s)
End contact materialSILVER NICKEL
Number of terminals11
operating hours10 ms
Maximum operating temperature85 °C
Minimum operating temperature-40 °C
PCB hole count11
physical size27.7mm x 20.7mm x 35.8mm
Relay actionMBB
Relay style3 FORM C
Relay function3PDT-CO
release time5 ms
Terminal length0.0048 inch
Termination typeSOLDER
55
55 Series - General purpose relays 7 - 10 A
Features
Printed circuit mount, general purpose
2, 3 & 4 Pole relays
55.12 - 2 Pole 10 A
55.13 - 3 Pole 10 A
55.14 - 4 Pole 7 A
AC coils & DC coils
Cadmium Free contacts (preferred version)
Contact material options
RT III (wash tight) option available
SERIES
55.12
55.13
55.14
Plug-in / PCB Relays
2 pole, 10 A
PCB mount
3 pole, 10 A
PCB mount
4 pole, 7 A
PCB mount
55.12
55.13
55.14
F
OR
UL
RATINGS SEE
:
“General technical information” page
V
Contact specification
Contact configuration
Rated current/Maximum peak current
Rated load AC1
Rated load AC15 (230 V AC)
Single phase motor rating (230 V AC)
Breaking capacity DC1: 30/110/220V
Minimum switching load
Standard contact material
Coil specification
Nominal voltage (U
N
)
Rated power AC/DC
Operating range
Holding voltage
Must drop-out voltage
Technical data
Mechanical life AC/DC
Electrical life at rated load AC1
Operate/release time
X-2013, www.findernet.com
Copper side view
Copper side view
Copper side view
2 CO (DPDT)
A
VA
VA
kW
A
10/20
250/400
2,500
500
0.37
10/0.25/0.12
300 (5/5)
AgNi
V AC (50/60 Hz)
V DC
VA (50 Hz)/W
AC
DC
AC/DC
AC/DC
cycles
cycles
ms
1.5/1
(0.8…1.1)U
N
(0.8…1.1)U
N
0.8 U
N
/0.5 U
N
0.2 U
N
/0.1 U
N
20 · 10
6
/50 · 10
6
200 · 10
3
10/5
4
1,000
–40…+85
RT I
3 CO (3PDT)
10/20
250/400
2,500
500
0.37
10/0.25/0.12
300 (5/5)
AgNi
6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240
6 - 12 - 24 - 48 - 60 - 110 -125 - 220
1.5/1
(0.8…1.1)U
N
(0.8…1.1)U
N
0.8 U
N
/0.5 U
N
0.2 U
N
/0.1 U
N
20 · 10
6
/50 · 10
6
200 · 10
3
10/5
4
1,000
–40…+85
RT I
4 CO (4PDT)
7/15
250/250
1,750
350
0.125
7/0.25/0.12
300 (5/5)
AgNi
Rated voltage/Maximum switching voltage V AC
mW (V/mA)
1.5/1
(0.8…1.1)U
N
(0.8…1.1)U
N
0.8 U
N
/0.5 U
N
0.2 U
N
/0.1 U
N
20 · 10
6
/50 · 10
6
150 · 10
3
11/3
4
1,000
–40…+85
RT I
Insulation between coil and contacts (1.2/50 µs) kV
Dielectric strength between open contacts V AC
Ambient temperature range
Environmental protection
Approvals
(according to type)
°C
1
Comment on Deyisupport's excellent blog posts and win gifts!
Comment on the blog, get a surprise, grab the post to win a gift~ Comment on Deyisupport's excellent blog, grab the post to win a gift event grandly opened! Event time: From now until January 20, 2014...
phantom7 Analogue and Mixed Signal
ART-Pi Evaluation RTE Environment Build RTOS Project
[i=s]This post was last edited by BinWin on 2021-6-8 22:36[/i]I am very lucky to get the opportunity to review ART-Pi. Without further ado, let's start powering it up and using it. It can be seen that...
BinWin Real-time operating system RTOS
Tablet computer based on SEED-DIM3517
Tablet computer based on SEED-DIM3517...
zhuhaijun753 ARM Technology
Ask about the address allocation of local variables
I use IAR3.2, F149 chip. When programming, I defined a local variable in the timer interrupt. During hardware simulation, I observed in the WATCH window that this variable has an initial value of 102 ...
niuqing Microcontroller MCU
How to use .net compact framework2.0 of vs2005 to develop Wince program? Urgent!
I developed a WinCE project with vs2005, which can run on a PC, but when I put it on the development board, I get a Not Supported Exception when I run the program. I used a generic class List<>, which...
wangliqin_85 Embedded System
stm32 rtc (transfer)
1: For 32768HZ crystal, any 6pF--12.5pF is fine (except for those with quality problems), not the legendary beast. 2 (Important): At least one ceramic capacitor (100nF X7R dielectric material) must be...
fuqing5542 stm32/stm8

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2565  1040  1336  600  2188  52  21  27  13  45 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号