Off-Line PC Mount Transformer
ELECTRONICS INC.
EPC3079-X
• Dual Primaries : 115 V / 230 V
• UL 94V-0 Recognized Components
• UL 1446 Class F Insulation System
• Meets or exceeds CSA/TUV/VDE Specifications
for Creepage, Clearance and Dielectric Strength
Electrical Parameters @ 25° C
Part
Number
EPC3079-1
EPC3079-2
EPC3079-3
EPC3079-4
EPC3079-5
EPC3079-6
EPC3079-7
Primary Voltage
Series
Parallel
Connection
Connection
115
115
115
115
115
115
115
Secondary Voltage
Parallel
Series
Connection
Connection
Secondary Current (A-Rms)
Parallel
Series
Connection
Connection
.500
.400
.310
.250
.210
.180
.140
Power
Rating
(VA)
5.0
5.0
5.0
5.0
5.0
5.0
5.0
1.0
10
230
5.0
0.82
12.6
230
6.3
0.62
16
230
8.0
0.50
20
230
10
0.42
24
230
12
0.36
28
230
14
0.28
36
230
18
• Switching Frequency :
50 Hz - 500 Hz
• Isolation :
4000 Vrms •
Package
1.630
(41.40)
1.440
(36.58)
Pri.
4
3
2
1.380
(35.05)
1
Schematic
Sec.
8
7
6
5
.188 (4.76)
.200
(5.08)
.400
(10.16)
.800
(20.32)
.025 Sq.
(.630)
1.00
(25.40)
5
6
1
2
Mounting Screw Size #4
(Qty. : 2)
Screw
Hole
7
8
3
4
Unless Otherwise Specified Dimensions are in Inches /mm ± .010 /.25
PCA ELECTRONICS, INC.
16799 SCHOENBORN ST.
NORTH HILLS, CA 91343
Product performance is limited to specified parameters. Data is subject to change without prior notice.
CSC3079-X
Rev. -
7/11/02
TEL: (818) 892-0761
FAX: (818) 894-5791
http://www.pca.com