EEWORLDEEWORLDEEWORLD

Part Number

Search

KG492A2TXA261XCV01

Description
Rocker Switch, DPDT, Latched, 10A, 12VDC, Solder/quick Connect Terminal, Rocker Actuator, Panel Mount
CategoryMechanical and electronic products    switch   
File Size192KB,5 Pages
ManufacturerAPEM
Environmental Compliance  
Download Datasheet Parametric View All

KG492A2TXA261XCV01 Overview

Rocker Switch, DPDT, Latched, 10A, 12VDC, Solder/quick Connect Terminal, Rocker Actuator, Panel Mount

KG492A2TXA261XCV01 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerAPEM
Reach Compliance Codecompliant
ECCN codeEAR99
Actuator typeROCKER
body width20 mm
body height35.5 mm
Body length or diameter43.7 mm
Contact (AC) maximum rated R load10A@250VAC
Maximum contact current (AC)10 A
Maximum contact current (DC)10 A
Contact (DC) maximum rated R load10A@12VDC
Maximum contact voltage (AC)250 V
Maximum contact voltage (DC)12 V
Electrical life10000 Cycle(s)
JESD-609 codee4
Manufacturer's serial numberKG
Installation featuresPANEL MOUNT
Maximum operating temperature65 °C
Minimum operating temperature-10 °C
method of packingBULK
sealIP65
surface mountNO
Switch actionLATCHED
switch functionDPDT
Switch typeROCKER SWITCH
Terminal surfaceSilver (Ag)
Termination typeSOLDER/QUICK CONNECT
KG series
Power rocker switches
Distinctive features and specifications
K
Protected rocker
K
Illuminated or non-illuminated
K
VDE (EN 61058-1) approved
K
Sealed to IP65
ELECTRICAL SPECIFICATIONS
MATERIALS
• Currrent/voltage rating :
- functions 1 (ON-OFF) and 6 (ON-ON) : 15A 12VDC, 10A 24VDC,
15A 250VAC max., 10mA 14VDC min.
- functions 4 ( ON ON ON) and 4-1R (ON ON MOM) :
8A 12VDC, 5A 24VDC, 8A 250VAC max.
- other functions : 10A 12VDC, 8A 24VDC, 10A 250VAC max.
• VDE approved ratings : 12(4)A 250VAC, T85/55°C
• Initial contact resistance : 10 mΩ max. at 1A 2VDC
• Insulation resistance : 1.000 MΩ min. at 500VDC
• Dielectric strength : 2.000 Vrms 50 Hz min. between terminals
• Electrical life : 10.000 cycles min.
• Mechanical life : 2 position models : 100.000 cycles min.
3 position models : 30.000 cycles min.
ENVIRONMENTAL SPECIFICATIONS
• Case : thermoplastic UL94-V0
• Terminals : brass, silver plated
• Contacts : silver grain
• Contact roller : brass, nickel plated
AGENCY APPROVAL
EN 61058-1
Availability
: double pole models,
functions ON-OFF and ON-ON.
Marking
: to order switches
marked VDE, add “VDE” at the
end of model number.
• Degree of protection : IP65
• Shock resistance : 100 g according to IEC 512-4, test 6c
• Vibration resistance : 10-500 Hz - 10 g according to IEC 512-4, test 6d
• Salt spray resistance : 96 hours according to IEC 512-6, test 11f
• Operating temperature : 2 position models : -40°C to + 85°C
3 position models : -10°C to + 65°C
MATRIX MOUNTING
25.00 mini.
(.984 min.)
4.00
(.157)
49.00 mini.
(1.929 min.)
12.20
(.480)
Dimensions
: First dimensions are in mm while
inches are shown as bracketed numbers.
Tolerance
: The general tolerance for
dimensions in this brochure is ± 0,3 (.012).
Overall dimension tolerance is ± 0,5 (.020).
Packaging unit
: 40 pieces
Dimensions, specifications and data shown in this brochure are subject to change without notice.
26
www.apem.com
APEM
Microwave Transmission Technology and Application of Television Signals
[i=s]This post was last edited by jameswangsynnex on 2015-3-3 19:58[/i][Abstract]The microwave transmission technology of television signals is introduced, the characteristics of microwave transmissio...
JasonYoo Mobile and portable
Why does the data received by 430 from hx711 not change?
[font=宋体]It's just my program[/font] [font=宋体]The LCD only shows a fixed number and it doesn't change[/font] [font=宋体]I don't know why? [/font] [font=宋体]Is there anyone who knows how to do this? [/fon...
宇飞天 Electronics Design Contest
FPGA beginners getting started, please give me some advice
Let me talk about my own situation first: I just finished learning Verilog HDL by myself, downloaded ModelSim-Altera 6.4a, and can use it to do some simple simulations, and the test program is mainly ...
scm FPGA/CPLD
[Newbie Help] Routing nodes broadcast information to other routing nodes
If I have 1 coordinator and N routers, I hope that after networking, I can realize information exchange between N points, and any routing node broadcasts to other routing nodes. But I can't find simil...
a102308667 RF/Wirelessly
Electronic Transformer
[i=s]This post was last edited by paulhyde on 2014-9-15 09:21[/i] Electronic Transformer...
wuhanjikaifei Electronics Design Contest
Battery internal resistance measurement methods used in two industries
[size=14px] In industry applications, the precise measurement of battery internal resistance is carried out through special equipment. Let me talk about the battery internal resistance measurement met...
bjhyyq Power technology

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1561  1359  64  1331  2242  32  28  2  27  46 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号