EEWORLDEEWORLDEEWORLD

Part Number

Search

0459844461

Description
36 CONTACT(S), FEMALE, POWER CONNECTOR, SOLDER, RECEPTACLE
CategoryThe connector    The connector   
File Size420KB,7 Pages
ManufacturerMolex
Websitehttps://www.molex.com/molex/home
Environmental Compliance
Download Datasheet Parametric View All

0459844461 Overview

36 CONTACT(S), FEMALE, POWER CONNECTOR, SOLDER, RECEPTACLE

0459844461 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerMolex
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
Is SamacsysN
Other featuresPOLARIZED
Body/casing typeRECEPTACLE
Connector typeRECTANGULAR POWER CONNECTOR
Contact to complete cooperationGOLD (30)
Contact completed and terminatedTIN (150)
Contact point genderFEMALE
Contact materialNOT SPECIFIED
DIN complianceNO
empty shellNO
Filter functionNO
IEC complianceNO
JESD-609 codee3
MIL complianceNO
Manufacturer's serial number45984
Plug informationMULTIPLE MATING PARTS AVAILABLE
Mixed contactsYES
Installation typeBOARD
OptionsGENERAL PURPOSE
Shell materialPOLYETHYLENE
Termination typeSOLDER
Total number of contacts36
UL Flammability Code94V-0
Base Number Matches1
This document was generated on 05/27/2010
PLEASE CHECK WWW.MOLEX.COM FOR LATEST PART INFORMATION
Part Number:
Status:
Overview:
Description:
0459844461
Active
extreme_lphpower
1.27mm (.050"), 12.00mm (.472") Pitch, EXTreme LPHPower™ Receptacle Header,
Right Angle, 4 Power Contacts, 32 Signal Contacts, Select Gold (Au) Plating, for
3.18mm (.125") Thick PC Board, with Guide Posts, with Press-fit Plastic Pegs
Documents:
3D Model
Drawing (PDF)
Product Specification PS-45984-001 (PDF)
RoHS Certificate of Compliance (PDF)
image - Reference only
Series
Agency Certification
CSA
UL
LR19980
E29179
EU RoHS
China RoHS
ELV and RoHS
Compliant
REACH SVHC
Contains SVHC: No
Halogen-Free
Status
Halogen-Free
Need more information on product
environmental compliance?
Email productcompliance@molex.com
For a multiple part number RoHS Certificate of
Compliance, click here
Please visit the Contact Us section for any
non-product compliance questions.
General
Product Family
Series
Application
Overview
Product Name
PCB Receptacles
45984
Board-to-Board
extreme_lphpower
EXTreme LPHPower™
Physical
Circuits (Loaded)
Circuits (maximum)
Circuits Detail
Color - Resin
Durability (mating cycles max)
Flammability
Glow-Wire Compliant
Guide to Mating Part
Keying to Mating Part
Lock to Mating Part
Material - Metal
Material - Plating Mating
Material - Plating Termination
Material - Resin
Number of Rows
Orientation
PC Tail Length (in)
PC Tail Length (mm)
PCB Locator
PCB Retention
PCB Thickness Recommended (in)
PCB Thickness Recommended (mm)
Packaging Type
Pitch - Mating Interface (in)
Pitch - Mating Interface (mm)
Plating min: Mating (µin)
Plating min: Mating (µm)
Plating min: Termination (µin)
Plating min: Termination (µm)
Polarized to Mating Part
Polarized to PCB
Stackable
Surface Mount Compatible (SMC)
36
36
4 Power, 32 Signal
Black
250
94V-0
No
Yes
Yes
No
High Performance Alloy (HPA), Phosphor Bronze
Gold
Tin
High Temperature Thermoplastic
2
Right Angle
0.177 In
4.50 mm
Yes
Yes
0.125 In
3.18 mm
Tray
0.050 In, 0.472 In
1.27 mm, 12.00 mm
30
0.75
150, 75
1.875, 3.75
Yes
Yes
No
Yes
Search Parts in this Series
45984Series
Mates With
45985 EXTreme LPHPower™ Headers,
1.57mm (.062") Card Edge
CC4072------Dual 4-input OR gate.pdf
CC4072------Dual 4-input OR gate This is a simple introduction to the CC4072 chip dual 4-input OR gate basic tutorial...
rain MCU
100 super practical questions and answers on the basics of oscilloscopes
1. How to use an oscilloscope to detect and analyze the reliability of a designed product? A: Oscilloscopes have long been one of the most effective tools for testing electronic circuits. By observing...
btty038 Test/Measurement
AD637RMS-DC conversion problem
AD637 is used to convert AC signals into DC: 1. When the input signal is the signal source, the frequency is 10.6kHz and the amplitude is about 4.5Vpp. The circuit design adopts figure 5 in the data s...
yunmeizhi1990 Analog electronics
Why is 485 communication isolated?
Why is 485 communication isolated?...
ljk926 Microcontroller MCU
Willful DIY: Naked Technology Life: Stripping Off POP3's Clothes
Some time ago, I wrote an article about the SMTP principle interaction process and implementation methods. In fact, a complete mail protocol system includes a client and a mail proxy server. Both the ...
wateras1 RF/Wirelessly
GCC 9.4 released: no longer mandatory code contribution copyright transfer to FSF
Reprinted from: https://www.cnbeta.com/articles/tech/1135425.htmIn addition to the release of GCC 9.4, the GCC Steering Committee today announced the deprecation of an existing long-standing policy: t...
dcexpert Talking

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 340  958  680  338  1875  7  20  14  38  2 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号