EEWORLDEEWORLDEEWORLD

Part Number

Search

MMC-13-A-6040-1-C-1-K-0

Description
Splitter/Coupler, 1X3 Port, 60/40 Ratio,
CategoryWireless rf/communication    Optical fiber   
File Size179KB,1 Pages
ManufacturerLaser Components USA Inc.
Download Datasheet Parametric View All

MMC-13-A-6040-1-C-1-K-0 Overview

Splitter/Coupler, 1X3 Port, 60/40 Ratio,

MMC-13-A-6040-1-C-1-K-0 Parametric

Parameter NameAttribute value
MakerLaser Components USA Inc.
Reach Compliance Codeunknow
Fiber optic equipment typesSPLITTER/COUPLER
Fiber type50/125, MMF
Maximum insertion loss6.7 dB
Maximum operating temperature85 °C
Minimum operating temperature-40 °C
Nominal operating wavelength1060 nm
Port configuration1X3
Split ratio/coupling ratio60/40
Fiber
Optics
FBT Coupler
Multimode Coupler
Specifications (50/50)
Parameter
Central Wavelength
Configuration
Insertion Loss*
Directivity
TDL
Operating & Storage Temperature
Package
Dimensions
(in mm)
Light Duty ( B )
Medium Duty ( L )
Heavy Duty (K, R)
3.0(Ф) x 55.0(L)
3.0(Ф) x 60(L)
100 x 12 x 8
3.0(Ф) x 60(L)
100 x 12 x 8
95 x 75 x 6
630, 850, 980, 1060, 1310, 1550 nm
1x2, 2x2
1x3
6.7 dB
6.4 dB
1x4
≤7.8
dB
7.5 dB
≥ 40 dB
≤ 0.2
dB
- 40° C ~ + 85° C
3.0(Ф) x 60(L)
100 x 12 x 8
95 x 75 x 6
3.0(Ф) x 60(L)
100 x 12 x 8
130 x 100 x 6
5.0(Ф) x 60(L)
135 x 100 x 10
130 x 100 x 8.5
1x8
11.5 dB
≤11
dB
1x16
15 dB
14.2 dB
50/125 Fiber
4.9 dB
4.6 dB
62.5/125, 100/140, 105/125 Fiber
Tap Coupler
Coupling
Ratio
60/40
70/30
80/20
90/10
95/5
99/1
Maximum Insertion Loss
50/125 µm
4.5/6.5 dB
3.9/8.0 dB
3.2/10.0 dB
2.7/13.5 dB
2.4/17.0 dB
1.4/22.0 dB
62.5/125 µm
3.6/5.8 dB
3.0/7.0 dB
2.4/9.0 dB
1.9/12.5 dB
1.5/16.5 dB
1.1/22.0 dB
100/140 µm &
105/125 µm
3.0/5.0 dB
2.3/6.3 dB
1.7/8.3 dB
1.2/12.0 dB
1.0/16.0 dB
0.8/22.0 dB
09/18 / V02 / IF / lightel/couplers/multimode-coupler
* All data tested under LED direct launching conditions.
Note1: All values specified are without connectors.
Note2: Higher performance specifications are available upon request.
Ordering Information
M M C
Port Number
12:
22:
13:
14:
18:
116:
1x2
2x2
1x3
1x4
1x8
1 x 16
Grade
A: A Grade
Coupling Ratio
xy % : xy %
EVEN: Even split
Fiber Type
Wavelength
A: 630 nm
B: 850 nm
C: 1060 nm
D: 980 nm
E: 1310 nm
H: 1550 nm
Fiber Length
1: 1 meter
2: 2 meter
S: Special
Pigtail Style
Connector
0: None
1: FC/PC
3: SC/ PC
9: Special
C: ST
(=Package style)
B: bare fiber
L: 900
m
loose tube
K: 2mm cable
R: 3mm cable
1: 50/125 µm
2: 62.5/125 µm
3: 100/140 µm
4: Special
5: 105/125 µm, NA=0.15
6: 105/125 µm, NA=0.22
1
Germany & Other Countries
Laser Components GmbH
Tel: +49 8142 2864 – 0
Fax: +49 8142 2864 – 11
info@lasercomponents.com
www.lasercomponents.com
United Kingdom
Laser Components (UK) Ltd.
Tel: +44 1245 491 499
Fax: +44 1245 491 801
info@lasercomponents.co.uk
www.lasercomponents.co.uk
[Raspberry Pi 4B Review] + OPENCV Simple License Plate Location
In recent years, license plate recognition has attracted more and more attention. Especially in intelligent transportation systems, license plate recognition plays a huge role. The automatic recogniti...
29447945 Special Edition for Assessment Centres
How does the 430 microcontroller detect the order in which its three pins jump in sequence?
The three pins of other modules (such as 1, 2, 3) will jump in sequence. It may be 1, 2, 3, or 3, 2, 1. The interval between their jumps will also vary slightly depending on the environment.I connecte...
chaengli Microcontroller MCU
! ! We are looking for supply chain managers, purchasing engineers, and production managers! !
Supply Chain SupervisorResponsibilities1 Continuously improve supplier management, cost control, delivery guarantee system and process2 Responsible for establishing and maintaining the procurement mat...
hardcoremotor Recruitment
Prepare emergency plans for ICS, EPKS and tricon control systems according to GB/T29639-2013
The main function of the emergency plan is that when the system cannot work normally, the instrument personnel can use the plan to promptly determine the cause of the failure and take emergency treatm...
yunrun Industrial Control Electronics
VxWorks File Capture
Hello everyone, I have the following questions: The file system is DosFd. I need to intercept a file. For example, if there is a 4M file, I want to delete the last 1M and only keep the first 3M. I can...
tanling79467240 Real-time operating system RTOS
PCB design considering EMC grounding techniques
In PCB design, grounding is an important measure to suppress noise and prevent interference. There are different grounding methods according to different circuits. Only correct grounding can reduce or...
szglmjh PCB Design

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1844  1540  680  806  1183  38  32  14  17  24 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号