Electromechanical Relay, 3PDT-CO, MBB, 121VDC (Coil), 1W@110VDCmW (Coil), Random, AC/DC Output
CategoryMechanical and electronic products    relay   
File Size3MB,14 Pages
ManufacturerFINDER
Download Datasheet Parametric View All

55.13.9.110.2081 Overview

Electromechanical Relay, 3PDT-CO, MBB, 121VDC (Coil), 1W@110VDCmW (Coil), Random, AC/DC Output

55.13.9.110.2081 Parametric

Parameter NameAttribute value
MakerFINDER
Reach Compliance Codecompli
body width20.7 mm
body height35.8 mm
Body length or diameter27.7 mm
Coil operating voltage (DC)88 V
Coil power1000 mW
Coil resistance12500 Ω
Maximum coil voltage (DC)121 V
Nominal coil voltage110 V
Coil/Input Power TypeDC
Contact (AC) maximum rated power R load2500VA@400VAC
Contact (AC) maximum rated R load20A@400VAC
Maximum contact current (AC)20 A
Maximum contact voltage (AC)400 V
Contact/Output Power TypeAC/DC
Dielectric strength between coil and contacts2000 Vrms
Dielectric strength between breaking contacts1000 Vrms
Electrical life200000 Cycle(s)
End contact materialSILVER CADMIUM OXIDE
Input switching control typeRandom
Number of terminals11
operating hours10 ms
Maximum operating temperature85 °C
Minimum operating temperature-40 °C
PCB hole count11
physical size27.7mm x 20.7mm x 35.8mm
Relay actionMBB
Relay style3 FORM C
Relay function3PDT-CO
release time5 ms
Terminal length0.0048 inch
Termination typeSOLDER
55
55 Series - General purpose relays 7 - 10 A
Features
Printed circuit mount, general purpose
2, 3 & 4 Pole relays
55.12 - 2 Pole 10 A
55.13 - 3 Pole 10 A
55.14 - 4 Pole 7 A
AC coils & DC coils
Cadmium Free contacts (preferred version)
Contact material options
RT III (wash tight) option available
SERIES
55.12
55.13
55.14
Plug-in / PCB Relays
2 pole, 10 A
PCB mount
3 pole, 10 A
PCB mount
4 pole, 7 A
PCB mount
55.12
55.13
55.14
F
OR
UL
RATINGS SEE
:
“General technical information” page
V
Contact specification
Contact configuration
Rated current/Maximum peak current
Rated load AC1
Rated load AC15 (230 V AC)
Single phase motor rating (230 V AC)
Breaking capacity DC1: 30/110/220V
Minimum switching load
Standard contact material
Coil specification
Nominal voltage (U
N
)
Rated power AC/DC
Operating range
Holding voltage
Must drop-out voltage
Technical data
Mechanical life AC/DC
Electrical life at rated load AC1
Operate/release time
X-2013, www.findernet.com
Copper side view
Copper side view
Copper side view
2 CO (DPDT)
A
VA
VA
kW
A
10/20
250/400
2,500
500
0.37
10/0.25/0.12
300 (5/5)
AgNi
V AC (50/60 Hz)
V DC
VA (50 Hz)/W
AC
DC
AC/DC
AC/DC
cycles
cycles
ms
1.5/1
(0.8…1.1)U
N
(0.8…1.1)U
N
0.8 U
N
/0.5 U
N
0.2 U
N
/0.1 U
N
20 · 10
6
/50 · 10
6
200 · 10
3
10/5
4
1,000
–40…+85
RT I
3 CO (3PDT)
10/20
250/400
2,500
500
0.37
10/0.25/0.12
300 (5/5)
AgNi
6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240
6 - 12 - 24 - 48 - 60 - 110 -125 - 220
1.5/1
(0.8…1.1)U
N
(0.8…1.1)U
N
0.8 U
N
/0.5 U
N
0.2 U
N
/0.1 U
N
20 · 10
6
/50 · 10
6
200 · 10
3
10/5
4
1,000
–40…+85
RT I
4 CO (4PDT)
7/15
250/250
1,750
350
0.125
7/0.25/0.12
300 (5/5)
AgNi
Rated voltage/Maximum switching voltage V AC
mW (V/mA)
1.5/1
(0.8…1.1)U
N
(0.8…1.1)U
N
0.8 U
N
/0.5 U
N
0.2 U
N
/0.1 U
N
20 · 10
6
/50 · 10
6
150 · 10
3
11/3
4
1,000
–40…+85
RT I
Insulation between coil and contacts (1.2/50 µs) kV
Dielectric strength between open contacts V AC
Ambient temperature range
Environmental protection
Approvals
(according to type)
°C
1
protel99 layer cannot be set
I have opened all the layers in my protel99 software, but when I draw, I can only see a single layer and I can't see the flying wires. I want to be able to see both the top and bottom floorsStartFragm...
forumal PCB Design
A perverted usage of macro definition in C language
When debugging a program, we often need to output some debugging information. When debugging is completed, it is no longer needed. So how can we quickly switch between debugging and release status? Us...
冰人 Embedded System
Using vc33 under win7 32 bit
Hello everyone, I plan to control vc33 through the emulator XDS510PLUS under Windows 7 32-bit, but I found that it is incompatible and cannot be used. So I have a few questions to ask: 1) The relation...
xcuresme Microcontroller MCU
Request help!!!
Please help me if you are experienced with M430F5438!!!What is the function of the 10-bit frequency integrator in the clock system circuit block diagram of M430F5438? ? ? What is the purpose of settin...
雨西关 Microcontroller MCU
Huawei Logic Level Design Specification Textbook
Huawei Logic Level Design Specification Textbook...
guoxiao69 Analog electronics
Xilinx Spartan-6 LX9 Microblaze Trial Experience
Fortunately, I got the opportunity to try Xilinx Spartan-6 LX9 Microblaze. Thanks to EE and the administrator. I had some contact with Altera before and this was my first contact with Xilinx, learning...
常见泽1 FPGA/CPLD

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 958  641  2748  2503  2560  20  13  56  51  52 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号