EEWORLDEEWORLDEEWORLD

Part Number

Search

255XCXP-125VDC

Description
Power/Signal Relay, 3PDT, Latched, 0.02A (Coil), 125VDC (Coil), 1800mW (Coil), 10A (Contact), 28VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount,
CategoryMechanical and electronic products    relay   
File Size353KB,2 Pages
ManufacturerStruthers-Dunn
Download Datasheet Parametric View All

255XCXP-125VDC Overview

Power/Signal Relay, 3PDT, Latched, 0.02A (Coil), 125VDC (Coil), 1800mW (Coil), 10A (Contact), 28VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount,

255XCXP-125VDC Parametric

Parameter NameAttribute value
Reach Compliance Codeunknow
ECCN codeEAR99
body width36.7 mm
body height94.4 mm
Body length or diameter66.8 mm
Maximum coil current (DC)0.02 A
Coil power1800 mW
Coil resistance6200 Ω
Maximum coil voltage (DC)125 V
Coil/Input Power TypeDC
Contact (AC) maximum rated R load10A@120VAC
Maximum contact current (AC)10 A
Maximum contact current (DC)10 A
Contact (DC) maximum rated R load10A@28VDC
Maximum contact voltage (AC)120 V
Maximum contact voltage (DC)28 V
Contact/Output Power TypeAC/DC
Electrical life100000 Cycle(s)
Installation featuresTHROUGH HOLE-STRAIGHT MOUNT
operating hours25 ms
Maximum operating temperature60 °C
Minimum operating temperature-20 °C
physical size66.8mm x 36.7mm x 94.4mm
GuidelineCSA; UL
Relay actionLATCHED
Relay function3PDT
Relay typePOWER/SIGNAL RELAY
release time20 ms
surface mountNO
Termination typeSOLDER
Base Number Matches1
255 Series - Industrial Latching Relays
3PDT or 4PST, 10 Amp
File No. E13224
The 255 Series is a two coil latching version of the general purpose type 219 relay. When the
operate coil is momentarily energized, contacts transfer and remain so even after coil power is
removed. The second coil when momentarly energized, provides electrical reset of the contacts.
All contacts operate from a common armature to prevent contatct overlapping. Coils are rated for
continous duty. Both coils can be energized at the same time with no damage. The operate coil is
dominant
GENERAL SPECIFICATIONS (@ 25° C)
Contacts:
Contact Configuration
Contact Material
Contact Rating
120 / 240VAC Resistive
28VDC Resistive
Contact Resistance, Initial
Coil:
Coils Available
Nominal Coil Power
Input Voltage Tolerance - AC
Input Voltage Tolerance - DC
Drop out voltage
Duty
Timing:
Operate Time (max)
Release Time (max)
Up to 3PDT or 4PST
Silver Alloy Gold Diffused
10 Amp / 5 Amp
10 Amp
100 milliohms max @ 6VDC
AC and DC
4.9VA 1.8W
85% to 110% of nominal
80% to 110% of nominal
10% of nominal
Continuous
25mS
20mS
Operate
255 Wire Diagram
(Top View)
6
5
4
3
2
1
Dielectric Strength:
1500Vrms
Across Open Contacts
1500Vrms
Between Mutally Insulated Points
100 Megohms min @ 500VDC
Insulation Resistance
Temperature:
Operating
Storage
Life Expectancy:
Electrical (full load operations)
Mechanical (no load operations)
Miscellaneous:
Mounting Position
Mating Socket
Enclosure
Weight
-20 to 60°C (-4 to 140°F)
-40 to 105°C (-40 to 221°F)
Reset
8
7
9
10
11
12
255XBX (DPDT)
6
5
4
3
2
1
Operate
100,000
10,000,000
Any
27390D
Clear Polycarbonate
11.8oz (300 grams)
6
Reset
8
7
9
10
11
12
255ABX (1 N.O + DPDT)
Reset
5
4
3
2
1
6
5
4
3
2
1
Operate
Operate
Reset
8
7
8
9
10
11
12
7
9
10
11
12
255XCX (3PDT)
255BXB (2 N.O. + 2 N.C.)
4/7
www.struthers-dunn.com
(843) 664-3303
Seeking routines for the CAN bus part of the STM32-SK development board
I recently started debugging the CAN bus and found that the STM32-SK development board connected CAN_TX and CAN_RX to two ordinary GPIOs (PB8 and PB9). I was curious about how two ordinary GPIOs can i...
BITCH stm32/stm8
Problems with frequency modulation using MAX2607
This is a verification board. The error is because the minimum spacing was changed when making a homemade PCB board. Please don't mind. L3 and L4 should be 120nh in theory, but since they were not ava...
VHDLI2C11 RF/Wirelessly
Job-Seeking English (III): A Complete English Vocabulary on Work Experience
[b][font=宋体][size=14pt]Work experience [/font][font=宋体]Work experience[/font][font=宋体]occupational history [/font][font=宋体]work experience[/font][font=宋体]professional history [/font][font=宋体]professio...
lijiaoeeworld Talking about work
TM4C123GXL remote code update implementation?
It is divided into two parts: 1. The resident program (including main) needs to realize the serial communication function, that is, wait for the PC to send the binary file bin of the user program (inc...
huye566 Microcontroller MCU
Test the blinky program of RL78G14 in CubeSuite+
[align=left]Environment Description: CubeSuite+ [/align][align=left]Hardware: RPB RL78G14 [/align][align=left] [/align][align=left] [/align][align=left] [/align][align=left]Purpose of the experiment: ...
蓝雨夜 Renesas Electronics MCUs
How to view the state machine?
I am new to Verilog. Can you please tell me what tool I can use to view the state machine flow chart I wrote? (For Xilinx chips)...
xiaoxin1 FPGA/CPLD

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 493  1372  2065  1549  1827  10  28  42  32  37 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号