Industrial Line – PMR20W Series
20W SINGLE & DUAL OUTPUT HIGH PERFORMANCE DC/DC CONVERTER
Specifications
INPUT
Voltage range
24V nominal input
9-36VDC
48V nominal input
18-75VDC
110V nominal input
43-160VDC
24V, 48V input
Common chock
110V input
Pi filter
24V input
50VDC 1sec max
48V input
100VDC 1sec max
110V input
170VDC 1sec max
30mA p-p, nominal Vin and full load.
Power up 30mS typ. Remote on/off 30mS typ.
Nominal Vin and constant resistive load.
24V input
9VDC max
48V input
18VDC max
110V input
43VDC max
24V input
8VDC max
48V input
16VDC max
110V input
40VDC max
Positive logic (standard):
DC/DC ON: Open or 3V < Vr < 15V
DC/DC OFF: Short or 0V < Vr < 1.2V
Negative logic (option):
DC/DC ON: Short or 0V < Vr < 1.2V
DC/DC OFF: Open or 3V < Vr < 15V
Remote off input current: 2.5mA, nominal Vin.
Input filter
Input surge voltage
Reflected ripple
Start up time
Start up voltage
Features
• Railway application
• 20 watts maximum output power
• Ultra low quiescent current
• Single output up to 4.5A
• High efficiency up to 89%
• 4:1 ultra wide input voltage range
• Six-sided continuous shield
• Fixed switching frequency
• CE mark meets 2006/95/EC, 93/68/EEC & 2004/108/EC
• UL60950-1, EN60950-1, IEC60950-1 & EN50155
safety approvals pending
• Compliant to RoHS EU Directive 2002/95/EC
• Suitable for Railway applications
Shutdown voltage
Remote ON/OFF
6)
OUTPUT
Power
Voltage accuracy
Min load
Voltage adjustability
5)
Line regulation
Load regulation
20W max.
±1%.
0%.
±10%, single output
Single ±0.2%. Dual ±0.5%. LL to HL at full load.
No load to full load: Single ±0.2%. Dual ±1%.
10% load to 90% load:
Single ±0.1%. Dual ±0.8%.
Cross regulation (dual) ±5%, asymmetrical load 25%/100% FL.
Ripple and noise
See table, At 20MHz bandwidth,
(measured with a 0.1uF/50V MLCC).
Temperature coefficient ±0.02%/°C max.
Transient response
250uS,recovery time 25% load step change.
Overload protection
3.3V output
3.7-5.4VDC
5V output
5.6-7.0VDC
12V output
13.5-19.6VDC
15V output
16.8-20.5VDC
Overload protection
150% max, % of FL at nominal input.
Short circuit protection Hiccup, automatics recovery.
ENVIRONMENTAL
Operating ambient temp
7)
Max case temperature
Storage temperature
Thermal impedance
8)
Thermal shock
Vibration
Relative humidity
–40°C to +101°C (with derating).
+105°C.
–55°C to +125°C.
Nature convection: 12°C/W.
Nature convection with heat-sink: 10°C/W.
EN61373, MIL-STD-810F.
EN61373, MIL-STD-810F.
5-95% RH.
GENERAL
Efficiency
Isolation voltage
Isolation resistance
Isolation capacitance
Switching frequency
Case material.
Base material
Potting material
Dimensions
Weight
MTBF
1)
STANDARDS
Safety standards
EMC
EMI
9)
ESD
Radiated immunity
Fast transient
10)
Surge
10)
Conducted immunity
See table.
1600VDC min, input to output.
1000VDC min, input (output) to case..
10
9
ohms, min.
3000pF, max.
330KHz typ.
Nickel-coated copper.
FR4 PCB.
Silicon (UL94-V0).
50.8 x 25.4 x 10.2 mm.
30g.
BELLCORE-TR-NWT-000332 1.630 x 10
6
hrs.
MIL-HDBK-217F 4.950 x 10
5
hrs.
IEC60950-1, UL60950-1, EN60950-1, EN50155.
Designed to meet EN50155.
EN55022, EN55011 24VDC & 48VDC Class B
110VDC Class A
EN61000-4-2Air ±8kV
Criteria A
EN61000-4-320V/m
Criteria A
EN61000-4-4 ±2kV
Criteria A
En61000-4-5 ±2kV
Critiera A
EN61000-4-610Vr.m.s.
Criteria A
20130404
INDUSTRIAL LINE
www.powerbox.info
Industrial Line – PMR20W Series
20W SINGLE & DUAL OUTPUT HIGH PERFORMANCE DC/DC CONVERTER
MODEL
NUMBER
PMR20-24S3P3W
PMR20-24S05W
PMR20-24S12W
PMR20-24S15W
PMR20-24D12W
PMR20-24D15W
PMR20-48S3P3W
PMR20-48S05W
PMR20-48S12W
PMR20-48S15W
PMR20-48D12W
PMR20-48D15W
PMR20-110S3P3W
PMR20-110S05W
PMR20-110S12W
PMR20-110S15W
PMR20-110D12W
PMR20-110D15W
INPUT
RANGE
9 ~ 36 VDC
9 ~ 36 VDC
9 ~ 36 VDC
9 ~ 36 VDC
9 ~ 36 VDC
9 ~ 36 VDC
18 ~ 75 VDC
18 ~ 75 VDC
18 ~ 75 VDC
18 ~ 75 VDC
18 ~ 75 VDC
18 ~ 75 VDC
43 ~ 160 VDC
43 ~ 160 VDC
43 ~ 160 VDC
43 ~ 160 VDC
43 ~ 160 VDC
43 ~ 160 VDC
OUTPUT
VOLTAGE
3.3 VDC
5 VDC
12 VDC
15 VDC
± 12 VDC
± 15 VDC
3.3 VDC
5 VDC
12 VDC
15 VDC
± 12 VDC
± 15 VDC
3.3 VDC
5 VDC
12 VDC
15 VDC
± 12 VDC
± 15 VDC
OUPUT CURRENT
MIN LOAD
FULL LOAD
0mA
4500mA
0mA
4000mA
0mA
1670mA
0mA
1330mA
0mA
± 833mA
0mA
± 667mA
0mA
4500mA
0mA
4000mA
0mA
1670mA
0mA
1330mA
0mA
± 833mA
0mA
± 667mA
0mA
4500mA
0mA
4000mA
0mA
1670mA
0mA
1330mA
0mA
± 833mA
0mA
± 667mA
OUTPUT
3)
RIPPLE&NOISE
75mVp-p
75mVp-p
100mVp-p
100mVp-p
100mVp-p
100mVp-p
75mVp-p
75mVp-p
100mVp-p
100mVp-p
100mVp-p
100mVp-p
75mVp-p
75mVp-p
100mVp-p
100mVp-p
100mVp-p
100mVp-p
NO LOAD
2)
EFFICIENCY
3)
INPUT CURRENT
6mA
85%
6mA
88%
6mA
89%
6mA
88%
6mA
88%
6mA
89%
4mA
85%
4mA
88%
4mA
89%
4mA
89%
4mA
88%
4mA
89%
3mA
85%
3mA
87%
3mA
88%
3mA
88%
3mA
88%
3mA
89%
CAPACITOR
4)
LOAD MAX
7000μF
5000μF
850μF
700μF
± 500μF
± 350μF
7000μF
5000μF
850μF
700μF
± 500μF
± 350μF
7000μF
5000μF
850μF
700μF
± 500μF
± 350μF
Notes:
1. BELLCORE TR-NWT-000332. Case 1: 50% Stress, Temperature at 40ºC. MIL-HDBK-217F Notice2 @Ta=25ºC, Full load(Ground, Benign, controlled environment)
2. Typical value at nominal input and no load.
3. Typical value at nominal input and full load.
4. Test by minimum input and constant resistive load.
5. Trimming allows the user to increase or decrease the output voltage set point of the module. This is accomplished by connecting an external resistor between the TRIM pin and either the
+OUTPUT pin or the -OUTPUT pin.
6. The CTRL pin voltage is reference to -INPUT. The order number please see product standard table.
7. Operating ambient temperature: Converter can meet the railway T2 and TX temperature requirement.
T2: -40ºC ~ +70ºC as all models , TX: -40ºC ~ +85ºC as power derating to 55% output power.(with Heat-sink as power derating to 70% output power)
Test condition with vertical direction by natural convection (20LFM).
8. Heat-sink is optional and P/N: 7G-0020C-F
9. EN55022 and EN55011
24VDC & 48VDC input: To meet Class B without external filter.
110VDC input: To meet Class A without external filter.
10. An external input filter capacitor is required if the module has to meet EN61000-4-4, EN61000-4-5.
The filter capacitor Powerbox suggest: 24VDC & 48VDC input: Nippon chemi-con KY series, 220μF/100V, ESR 48mW.
110VDC input: Rubycon BXF series, 100μF/250V.
CAUTION: This power module is not internally fused. An input line fuse must always be used.
Derating Curve
PMR20-24D15W Derating Curve
PMR20-24D15W Derating Curve With Heat-Sink (note 8)
INDUSTRIAL LINE
www.powerbox.info
Industrial Line – PMR20W Series
20W SINGLE & DUAL OUTPUT HIGH PERFORMANCE DC/DC CONVERTER
Efficiency
PMR20-24D15W Efficiency VS Input Voltage
PMR20-24D15W Efficiency VS Output Load
Mechanical
PIN CONNECTION
PIN
SINGLE
1
+INPUT
2
–INPUT
3
+OUTPUT
4
TRIM
5
–OUTPUT
6
CTRL
DUAL
+INPUT
–INPUT
+OUTPUT
COMMON
–OUTPUT
CTRL
EXTERNAL OUTPUT TRIMMING
Output can be externally trimmed by using the
method shown below.
TRIM UP
TRIM DOWN
5
4
R
D
4
3
R
D
PRODUCT STANDARD TABLE
OPTION
Negative logic remote ON/OFF(Standard)
Positive logic remote ON/OFF
Without ON/OFF logic pin
Negative remote logic ON/OFF without TRIM pin
Without ON/OFF logic &TRIM pin
Positive remote logic ON/OFF without TRIM pin
SUFFIX
-A
-B
-C
-D
-E
INDUSTRIAL LINE
www.powerbox.info