EEWORLDEEWORLDEEWORLD

Part Number

Search

2645LPA229001L0

Description
Rocker Switch, (on)-on, Momentary, 8A, 24VDC, Screw Terminal, Rocker Actuator, Panel Mount
CategoryMechanical and electronic products    switch   
File Size333KB,8 Pages
ManufacturerAPEM
Download Datasheet Parametric View All

2645LPA229001L0 Overview

Rocker Switch, (on)-on, Momentary, 8A, 24VDC, Screw Terminal, Rocker Actuator, Panel Mount

2645LPA229001L0 Parametric

Parameter NameAttribute value
MakerAPEM
Reach Compliance Codecompli
Actuator colorORANGE
Actuator length0.394 inch
Actuator materialPOLYAMIDE
Actuator typeROCKER
body width24.9936 mm
body height16.9926 mm
Body length or diameter32.004 mm
center contact materialSILVER
Contact (AC) maximum rated power R load0.16HP@250VAC
Contact (AC) maximum rated R load10A@250VAC
Maximum contact current (AC)10 A
Maximum contact current (DC)8 A
Contact (DC) maximum rated R load8A@24VDC
Contact function(ON)-ON
Contact resistance0.01 mΩ
Maximum contact voltage (AC)250 V
Maximum contact voltage (DC)24 V
Dielectric withstand voltage2500VRMS V
Electrical life10000 Cycle(s)
End contact materialSILVER
Shell materialPOLYAMIDE
Insulation resistance1000000000 Ω
Manufacturer's serial number2600
Installation featuresPANEL MOUNT
Maximum operating temperature85 °C
Minimum operating temperature-20 °C
surface mountNO
Switch actionMOMENTARY
Switch typeROCKER SWITCH
Terminal length0.437 inch
Termination typeSCREW
2600 series
Power rocker switches
Distinctive features and specifications
Three rocker shapes : plain, V-shaped or concave
Various rocker colours
Frame with protection guard on 2600LP models
Illuminated or non-illuminated
UL, CSA, VDE and NF (EN 61058-1) approved
ELECTRICAL SPECIFICATIONS
• Max. current/voltage rating with resistive load and approved ratings : see table below.
• Initial contact resistance : 10mΩ max.
• Insulation resistance : 1.000 MΩ min. at 500VDC
• Dielectric strength : 2.500 Vrms 50 Hz min. between terminals
3.000 Vrms 50 Hz min. between terminals and metal panel
• Electrical life : 10.000 cycles at full load
APPROVED RATINGS
FUNCTIONS
CSA (double pole)
CSA 22-2
DIRECT CURRENT
NF
EN 61058-1
UL (double pole)
UL 1054
VDE
EN 61058-1
24 VDC
12 VDC
D
ON - OFF
ON - ON
1/6 HP 125VAC
16A 125VAC
16A 250VAC
1/3 HP 250VAC
10A 125VAC
10A 250VAC
1/6 HP 125/250VAC
-
10A 125VAC
10A 250VAC
1/6 HP 250VAC
1/6 HP 125VAC
16A 125VAC
16A 250VAC
1/3 HP 250VAC
10A 125VAC
10A 250VAC
1/6 HP 125/250VAC
-
-
10(4)A 250VAC
T 85/55
-
10A
15A
ON - OFF - ON
ON - ON - ON
OTHERS
L I option
10(4)A 250VAC
-
L I option
10(4)A 250VAC
L I option
10(4)A 250VAC
-
L I option
10(4)A 250VAC
8A
5A
8A
10A
8A
10A
MATERIALS
GENERAL SPECIFICATIONS
• Case : melamine/polyester
• Frame : polyamide
• Actuator : polyamide
• Contacts :
A
: silver
C
: copper, silver plated
• Panel thickness : 0,8 mm to 4 mm (.031 to .157)
• Operating temperature :
- silver contacts (A) : -20°C to +85°C
- silver plated contacts (C) : -10°C to +55°C
AGENCY APPROVALS
EN 61058-1
EN 61058-1
Availability
: consult factory for details of approved models.
Marking
: approved models are standard marked.
APEM
www.apem.com
D-45
Good stuff to share with you
I wish you all a happy learning!...
zhuizhu12345 DSP and ARM Processors
Instructions on data transfer between arm and coprocessor registers
Today, I encountered the mcr and mrc instructions while reading the bootloader. I had never come across them before, so I checked the documentation to understand them. Both the mcr and mrc instruction...
呱呱 ARM Technology
Design of Battery Charger Using Mixed-Signal Approach
As battery-powered electronic devices become more widely used and more powerful, the need for battery charger designs with good applicability has also emerged. If only standard components are used, ba...
jimmyjf Power technology
Please help me figure out why after the water light starts cycling from left to right at the beginning of this program, other buttons don't work
#include #include #define GPI0_LED P0 #define GPI0_KEY P1 void Delay10ms(unsigned int c); unsigned char Key_Scan(); void LED1(); void LED2(); void LED3(); void LED4(); void LED5(); void LED6(); void L...
xinxinxin2015 51mcu
[RVB2601 Creative Application Development] Infrared Device Control
In the project, we plan to use infrared control equipment, so this article introduces how to write and send infrared equipment protocols. The following is based on the standard NEC infrared protocol. ...
流行科技 XuanTie RISC-V Activity Zone
How to Get PCB Pin Density
Can I directly get the average pin density of a PCB board in Altium Designer?...
dianzinihao PCB Design

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2585  1054  2094  1164  499  53  22  43  24  11 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号