256 x 9, 512 x 9, 1,024 x 9, 2,048 x 9, 4,096 x 9 and 8,192 x 9
COMMERCIAL AND INDUSTRIAL
TEMPERATURE RANGES
ABSOLUTE MAXIMUM RATINGS
(1)
Symbol
V
TERM
(2)
T
STG
I
OUT
Rating
Terminal Voltage with
Respect to GND
Storage Temperature
DC Output Current
Com'l & Ind'l
–0.5 to +5
–55 to +125
–50 to +50
Unit
V
°C
mA
RECOMMENDED OPERATING
CONDITIONS
Symbol
V
CC
GND
V
IH
V
IL
T
A
T
A
Parameter
Supply Voltage
Commercial/Industrial
Supply Voltage
Input High Voltage
Commercial/Industrial
Input Low Voltage
Commercial/Industrial
Operating Temperature
Commercial
Operating Temperature
Industrial
Min.
3.0
0
2.0
-0.5
0
-40
Typ.
3.3
0
—
—
—
—
Max.
3.6
0
5.5
0.8
70
85
Unit
V
V
V
V
°C
°C
NOTE:
1. Stresses greater than those listed under ABSOLUTE MAXIMUM RATINGS may cause
permanent damage to the device. This is a stress rating only and functional operation
of the device at these or any other conditions above those indicated in the operational
sections of the specification is not implied. Exposure to absolute maximum rating
conditions for extended periods may affect reliability.
2. V
CC
terminal only.
DC ELECTRICAL CHARACTERISTICS
(Commercial: V
CC
= 3.3V ± 0.3V, T
A
= 0°C to +70°C;Industrial: V
CC
= 3.3V ± 0.3V, T
A
= -40°C to +85°C)
IDT72V201
IDT72V211
IDT72V221
IDT72V231
IDT72V241
IDT72V251
Commercial and Industrial
(1)
t
CLK
= 10, 15, 20 ns
Typ.
—
—
—
—
—
—
Symbol
I
LI
(2)
I
LO
(3)
V
OH
V
OL
I
CC1
(4,5,6)
I
CC2
(4,7)
Parameter
Input Leakage Current (Any Input)
Output Leakage Current
Output Logic “1” Voltage, I
OH
= –2mA
Output Logic “0” Voltage, I
OL
= 8mA
Active Power Supply Current
Standby Current
Min.
–1
–10
2.4
—
—
—
Max.
1
10
—
0.4
20
5
Unit
µA
µA
V
V
mA
mA
NOTES:
1. Industrial temperature range product for the 15ns speed grade is available as a standard device. All other speed grades are available by special order.
2. Measurements with 0.4
≤
VIN
≤
VCC.
3.
OE
≥
V
IH,
0.4
≤
V
OUT
≤
V
CC
.
4. Tested with outputs disabled (I
OUT
= 0).
5. RCLK and WCLK toggle at 20 MHz and data inputs switch at 10 MHz.
6. Typical I
CC1
= 0.17 + 0.48*f
S
+ 0.02*C
L
*f
S
(in mA) with V
CC
= 3.3V, T
A
= 25
°
C, f
S
= WCLK frequency = RCLK frequency (in MHz, using TTL levels), data switching at f
S
/2,
C
L
= capacitive load (in pF).
7. All Inputs = V
CC
- 0.2V or GND + 0.2V, except RCLK and WCLK, which toggle at 20 MHz.
Sailing is gaining more and more attention. How to use modern technology to assist training and improve competition results is particularly important. Considering the real-time data collection in t...[Details]
In recent years, the market for mobile/portable devices such as smartphones and laptops has continued to grow rapidly. While these products continue to integrate more new features to enhance the ...[Details]
In public places such as schools, government agencies, factories and mines, as well as public corridors in residential areas, the phenomenon of long-burning lights is very common, which causes a h...[Details]
1. Introduction
Light control circuit plays a vital role in urban street lamps or corridor lighting. With light control circuit, the lights can be automatically turned on and off according to ...[Details]
When choosing a laptop battery, you should consider several factors, such as power, appearance, and quality.
Regarding power, we often see that a manufacturer uses values such as the number ...[Details]
Editor's note: In order to help technicians or engineers who have knowledge of PIC microcontroller assembly language quickly master the method of using C language to program PIC microcontrollers, t...[Details]
Vertical cavity surface emitting lasers (VCSELs) are gradually replacing traditional edge emitting lasers, especially in low bandwidth and short-distance communication systems where cost factors ar...[Details]
Capacitors
are basic components in various electronic devices and are widely used for bypassing, coupling,
filtering
, tuning, etc. in electronic circuits. However, to use capacitors,...[Details]
Since the late 1990s, with the demand for higher system efficiency and lower power consumption, the technological update of telecommunications and data communication equipment has promoted the deve...[Details]
0 Introduction
In order to improve the automation control of shortwave transmitters, so that they can automatically process from far to near, the technicians here use the ICS system to complete the ...[Details]
Fruit planting is an important part of China's agricultural development, and fruit tree pest control operations are becoming more and more important. At present, the overall level of pesticide applica...[Details]
Leakage current is generated by parasitic resistance paths between the measurement circuit and a nearby voltage source. This current can significantly reduce the accuracy of low current measurement...[Details]
Rated capacity refers to the maximum output power of the UPS (the product of voltage V and current A).
Usually, the UPS power supplies sold on the market are marked with "W" (watt) for smaller...[Details]
0 Introduction
With the rapid development of modern power electronics technology, various power electronic devices have been widely used in various fields such as power systems, industry, an...[Details]
Globally, the market for airbags and other restraint systems consists of different geographical regions, each with its own characteristics and needs. North America first introduced airbags in mass-...[Details]