Part Number

Search

313LBPLCZFLCT

Description
SUBMERSIBLE LEVEL TRANSMITTER
File Size90KB,2 Pages
ManufacturerETC2
Download Datasheet View All

313LBPLCZFLCT Overview

SUBMERSIBLE LEVEL TRANSMITTER

SUBMERSIBLE LEVEL TRANSMITTER
Model 313L
GENERAL PURPOSE
FEATURES:
All-welded, stainless steel construction
Rugged, all encapsulated electronics.
Leakproof
1/2” NPT conduit thread standard
Standard
PRESSURE RANGES:
• From 0-3 through 0-100 psig
(See ordering guide.)
ACCURACY:
• From
±0.1%
FSO (RSS) to
±0.5%
FSO (RSS)
(See specifications & ordering guide.)
with Option LJ
tapered inlet with
stand off plate
ORDERING GUIDE
Ordering: Specify model, and pressure range and indicate modifications or
accessories required.
Use the following codes to identify desired item. Example 313L-B-PZ-LJ
MODEL
SERIES
RANGE
OPTIONS
MODEL
313L 4-20mA
SERIES
B
±0.5%
FSO (RSS)
C
±0.2%
FSO (RSS)
D
±0.1%
FSO (RSS)
•/•/•
OPTIONS
AA
None (standard connector)
CZ
Alternate cable length (specify)
ALTERNATE PRESSURE PORT
FH
1/8” NPT (F)
FL
1/8” NPT (M)
LD
Tapered inlet
LJ
Tapered inlet with standoff plate
PRESSURE RANGE
psi
in wc
PG
3
XK
100
PJ
5
XM
150
PL
7.5
XO
200
PN
10
XQ
300
PP
15
PR
20
PO
25
PT
30
PV
50
PX
75
PZ
100
GENERAL
CT
Tefzel jacketed cable
GA
Standardized output to
±0.5%
FSO
GB
Alternate output, pressure units, or full scale
outputs that are non-standard
GE
Improved temperature compensation to
±0.5%
FSO
unless otherwise specified
GG
Alternate calibration signal
GH
Internal calibration resistor set to 100
±0.5%
FSO
unless other wise specified
JH
Remote cable mounted (in-line) zero & span controls. 3’ cable on open
side. Length of cable on closed side as required. (500’ maximum)
GZ
Customer special
Specifications printed on reverse side of this brochure.
GP:50 reserves the right to make product improvements and amendments to the product specification stated throughout this
brochure without prior notification. Please contact the factory on all critical dimensions and specifications for verification.
TOPE Co., Ltd.
Tel. (02) 8228-0658 • Fax. (02) 8228-0659 • E-mail: tope@ms1.hinet.net • Website: www.sensor.com.tw
SL5B-313L.02C
How to choose between DT4215 and 15B for multimeter selection
I am planning to buy a multimeter. Most of the use scenarios require testing voltages of 600-900V (occasionally overvoltages of 1000+), so I have been using Fluke's 15B+. The meters in the company are...
bigbat Analog electronics
Development process of 6833
I would like to ask you guys: I am using MT68332 microcontroller recently. I would like to ask about the development process. I use the tool sds. My laptop does not have a parallel port. I would like ...
azhe Embedded System
How to use ADC12 to measure the power supply of MSP430X149
Connect the ××cc and DVcc of 149 to the positive pole of the power supply, and the ××ss to the negative pole, and then use ADC12 for testing. The program is as follows;#includevoid main(void){volatile...
kongxianglong Microcontroller MCU
Probe Technology Primer
Probe Technology Primer Personal safety is of utmost importance when measuring electronic systems or circuits. You need to be sure to understand the performance and usage regulations of the measuremen...
feifei PCB Design
Found the problem with sensortile
After searching for a day and repeatedly comparing with the schematic diagram, I found that the U2 (LDO) on the SensorTile board had no output. This is a 1.8V LDO, which provides basic power to the sy...
dcexpert ST Sensors & Low Power Wireless Technology Forum
D-LC resonant amplifier D topic 172697592 group
[i=s] This post was last edited by paulhyde on 2014-9-15 08:58 [/i] D-LC Resonant Amplifier D Question 172697592 Group D-LC Resonant Amplifier D Question 172697592 Group...
蓝盾 Electronics Design Contest

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1079  921  2761  861  2403  22  19  56  18  49 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号