EEWORLDEEWORLDEEWORLD

Part Number

Search

313LCPJCZFLCT

Description
SUBMERSIBLE LEVEL TRANSMITTER
File Size90KB,2 Pages
ManufacturerETC2
Download Datasheet View All

313LCPJCZFLCT Overview

SUBMERSIBLE LEVEL TRANSMITTER

SUBMERSIBLE LEVEL TRANSMITTER
Model 313L
GENERAL PURPOSE
FEATURES:
All-welded, stainless steel construction
Rugged, all encapsulated electronics.
Leakproof
1/2” NPT conduit thread standard
Standard
PRESSURE RANGES:
• From 0-3 through 0-100 psig
(See ordering guide.)
ACCURACY:
• From
±0.1%
FSO (RSS) to
±0.5%
FSO (RSS)
(See specifications & ordering guide.)
with Option LJ
tapered inlet with
stand off plate
ORDERING GUIDE
Ordering: Specify model, and pressure range and indicate modifications or
accessories required.
Use the following codes to identify desired item. Example 313L-B-PZ-LJ
MODEL
SERIES
RANGE
OPTIONS
MODEL
313L 4-20mA
SERIES
B
±0.5%
FSO (RSS)
C
±0.2%
FSO (RSS)
D
±0.1%
FSO (RSS)
•/•/•
OPTIONS
AA
None (standard connector)
CZ
Alternate cable length (specify)
ALTERNATE PRESSURE PORT
FH
1/8” NPT (F)
FL
1/8” NPT (M)
LD
Tapered inlet
LJ
Tapered inlet with standoff plate
PRESSURE RANGE
psi
in wc
PG
3
XK
100
PJ
5
XM
150
PL
7.5
XO
200
PN
10
XQ
300
PP
15
PR
20
PO
25
PT
30
PV
50
PX
75
PZ
100
GENERAL
CT
Tefzel jacketed cable
GA
Standardized output to
±0.5%
FSO
GB
Alternate output, pressure units, or full scale
outputs that are non-standard
GE
Improved temperature compensation to
±0.5%
FSO
unless otherwise specified
GG
Alternate calibration signal
GH
Internal calibration resistor set to 100
±0.5%
FSO
unless other wise specified
JH
Remote cable mounted (in-line) zero & span controls. 3’ cable on open
side. Length of cable on closed side as required. (500’ maximum)
GZ
Customer special
Specifications printed on reverse side of this brochure.
GP:50 reserves the right to make product improvements and amendments to the product specification stated throughout this
brochure without prior notification. Please contact the factory on all critical dimensions and specifications for verification.
TOPE Co., Ltd.
Tel. (02) 8228-0658 • Fax. (02) 8228-0659 • E-mail: tope@ms1.hinet.net • Website: www.sensor.com.tw
SL5B-313L.02C
TI Blog - Tips for Debugging Audio Amplifiers
[i=s]This post was last edited by qwqwqw2088 on 2020-5-11 11:40[/i]1. Component placement TheClass D amplifier generates PWM pulses, the speaker terminals are bridge-tied load configuration, and the s...
qwqwqw2088 Analogue and Mixed Signal
Ask the moderator (2)
Thank you, moderator.Moderator also knows that I am definitely not a microwave researcher. The thing is this: our experiment requires that one microwave be equally divided into two paths, and then one...
xujia525 RF/Wirelessly
Testimonials
From now on, eeworld has my presence....
永远菲 Buy&Sell
TI C2000 TMS320F28335 timer configuration
[align=left][color=rgb(102, 102, 102)][font=Roboto, Helvetica,]TMS320F28335 has three CPU Timers, namely Timer0, Timer1, and Timer2. Timer2 is reserved for the operating system DSP/BIOS. When the oper...
Jacktang Microcontroller MCU
How is the 4-20mA output circuit of a pressure sensor or temperature sensor usually implemented?
[i=s]This post was last edited by zjqmyron on 2019-12-2 09:33[/i]How is the 4-20mA output circuit of pressure sensor and temperature sensor usually implemented?How competitive is this GP8102 solution?...
zjqmyron Integrated technical exchanges
High-fidelity inverter
High accuracy...
zhshmzd123654 Power technology

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 274  2798  1982  444  930  6  57  40  9  19 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号