EEWORLDEEWORLDEEWORLD

Part Number

Search

325025H

Description
3AB Slo-Blo Fuse 325/326 Series
File Size90KB,1 Pages
ManufacturerLittelfuse
Websitehttp://www.littelfuse.com
Download Datasheet View All

325025H Overview

3AB Slo-Blo Fuse 325/326 Series

Next
Previous
Axial Lead and Cartridge Fuses
Ceramic Body
3AB
Slo-Blo
®
Fuse 325/326 Series
UL
®
®
®
QPL
Ceramic body construction permits higher interrupting ratings and volt-
age ratings. Ideal for applications where high current loads are expected.
ELECTRICAL CHARACTERISTICS:
% of Ampere
Rating
110%
135%
200%
Ampere
Rating
1/100–30
1/100–30
1/100–3.2
4 – 30
Opening
Time
hours,
Minimum
hour,
Maximum
sec.,
Min.;
30 sec.
Max.
sec.,
Min.;
60 sec.
Max.
4
1
5
5
AGENCY APPROVALS:
Listed by Underwriters Laboratories from 1/4
through 10 amperes. Certified by CSA from 1/4 through 30 amperes.
Recognized under the component program of Underwriters Laboratories
for 12-30A.
AGENCY FILE NUMBERS:
UL E10480, CSA LR 29862.
FUSES TO MIL SPEC:
See F03B cartridge type in Military Section.
326
000
Series
6.985 (.275")
6.35 (.25")
31.75
(1.25")
325
000
Series
0.813 (.032") (
1/100
-15A)
1.016 (.040") (20 -30A)
PATENTED
INTERUPTING RATING:
0.010 - 20A
25 - 30A
0.010 - 3.2A
4 - 20A
Cartridge
Catalog
Number
326.010
326.031
326.062
326.100
326.125
326.150
326.175
326.187
326.200
326.250
326.300
326.375
326.400
326.500
326.600
326.700
326.750
326.800
326
001
326
01.2
326
1.25
326
01.5
326
01.6
326
002
326
02.5
326
02.8
326
003
326
03.2
326
004
326
005
326
6.25
326
007
326
008
326
010
326
012
326
015
326
020
326
025
326
030
10,000A @ 125VAC
400A @ 125VAC
100A @ 250VAC
400A @ 250VAC
Axial Lead
Catalog
Number
325.010
325.031
325.062
325.100
325.125
325.150
325.175
325.187
325.200
325.250
325.300
325.375
325.400
325.500
325.600
325.700
325.750
325.800
325
001
325
01.2
325
1.25
325
01.5
325
01.6
325
002
325
02.5
325
02.8
325
003
325
03.2
325
004
325
005
325
6.25
325
007
325
008
325
010
325
012
325
015
325
020
325
025
325
030
Nominal
Resistance
Cold Ohms
3300.0000
330.
91.0
33.3
22.3
15.3
8.84
7.67
6.72
4.40
3.20
2.14
1.92
1.29
0.940
0.716
0.636
0.568
0.386
0.284
0.266
0.196
0.175
0.120
0.0830
0.0690
0.0600
0.0535
0.0755
0.0518
0.0343
0.0225
0.0191
0.0131
0.0066
0.0049
0.0033
0.0024
0.0019
Nominal
Melting I
2
t
A
2
Sec.
0.00148
0.0110
0.0276
0.0870
0.100
0.143
0.220
0.230
0.213
0.432
0.690
1.20
1.33
2.50
3.90
6.42
7.00
8.20
16.3
22.0
24.0
40.1
45.0
80.0
136.0
170.0
200.0
214.0
9.71
25.0
60.4
47.3
67.1
137.0
129.0
245.0
575.0
1030.0
1690.0
32.385
(1.275")
38.1
(1.50") TYP.
Axial Lead Material: Solder coated copper.
ORDERING INFORMATION:
Ampere
Rating
1/100
1/32
1/16
1/10
1/8
15/100
.175
3/16
2/10
1/4
3/10
3/8
4/10
1/2
6/10
7/10
3/4
8/10
1
1
2
/
10
1
1
/
4
1
1
/
2
1
6
/
10
2
2
1
/
2
2
8
/
10
3
3
2
/
10
4
5
6
1
/
4
7
8
10
12
15
20
25
30
Voltage
Rating
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
125
125
Average Time Current Curves
.375A
.500A
.750A
1.0A
1.5A
2.0A
2.5A
3.0A
3.5A
4.0A
5.0A
1000
8
100
10
TIME IN SECONDS
1
0.1
0.01
0.05 0.1
1
10
CURRENT IN AMPERES
100
1000
w w w. l i t t e l f u s e . c o m
293
AXIAL LEAD AND
CARTRIDGE FUSES
The process of WEBENCH design + 5V to 3V power supply design
The device is powered by a 5V power supply, but in addition to the 5V power supply, there are also ICs with a 3V working voltage in the mainboard system, so a 5V to 3V voltage conversion power supply ...
armcu Analogue and Mixed Signal
Experiment 7. Lamp with switch
1. Experimental results All the lights are off. Then I press a button and the ()th light comes on. Then I press another button and the ()th light comes on. When I release the button, the light goes ou...
rain MCU
Sony speaker disassembly
[i=s]This post was last edited by dcexpert on 2015-5-29 15:38[/i] I just disassembled a Sony speaker. It was a bit difficult without special tools. My fingernails were almost broken.It is still analog...
dcexpert Talking
Application principle of thermocouple temperature measurement
Thermocouples are one of the most commonly used temperature detection elements in industry. Its advantages are: ① High measurement accuracy. Because the thermocouple is in direct contact with the obje...
aq2 Industrial Control Electronics
Which transistor-controlled MOS tube switch circuit is better?
Which of the following control circuits is better?The MOS tube is turned on with 12V, and the 51 microcontroller is powered by 5V. I am not sure which of the following two control circuits is better. ...
Knight97538 Power technology
What is the circle for CLKOUT?
What is the dot on CLKOUT? What is generated on the PCB? I saw it in someone else's circuit diagram. It is already a PDF and I can't see the prototype....
cl17726 PCB Design

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1086  2340  763  267  2253  22  48  16  6  46 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号