EEWORLDEEWORLDEEWORLD

Part Number

Search

330R102U063JS0

Description
-55 ˚C to 105 ˚C Ultra-Long-Life, Switching Power Grade Radial High Ripple and Ultra-Long Life
File Size361KB,5 Pages
ManufacturerETC2
Download Datasheet View All

330R102U063JS0 Overview

-55 ˚C to 105 ˚C Ultra-Long-Life, Switching Power Grade Radial High Ripple and Ultra-Long Life

Type 330
–55 °C to 105 °C Ultra-Long-Life, Switching Power Grade Radial
High Ripple and Ultra-Long Life
The Type 330 is the ultra-long-life version of the Type 300 capacitor.
With an astonishing, 50,000-hour
expected life operating
continuously at full load and 65 ºC the 330 is the choice for power
supply outputs and UPS battery stiffening. The exceptionally low
ESRs enable high ripple-current capability. With series inductance
of 12 to 16 nH and ripple currents to 16 amps one of these capacitors
can save by replacing three or four of the 12.5 mm diameter
capacitors routinely at the output of switching power supplies. Type
330 R delivers even lower ESR and higher ripple. Type 330 has three
leads for rugged, reverse-proof mounting. Two leads are available as
Types 331 and 331R.
Highlights
Specifications
Operating Temperature:
Rated Voltage:
Capacitance:
Capacitance Tolerance:
Leakage Current:
Cold Impedance:
Ripple Current Multipliers:
• Expected Life > 20 years @ 45 °C
• Ripple Current to 16 amps
• ESRs to 6
• > 90% capacitance at –40 °C
• Replaces multiple capacitors
–55 °C to +105 °C
6.3 to 250 Vdc
270 µF to 33,000 µF
6.3 to 100 Vdc; –10 + 75%, 160 to 250 Vdc; –10 + 50%
≤ 0.5 √CV µA, 4 mA max, 5 min.
–55 °C multiple of 25 °C Z ≤ 4 for 6.3 & 7.5 V, 3 for 10 to 50 V,
2 for > 50 V
Ambient Temperature
45 °C
1.66
55 °C
1.52
65 °C
1.37
75 °C
1.20
85 °C
1.00
95 °C
0.75
105 °C
0.36
Frequency
50 Hz 60 Hz 120 Hz
.77” Diameter
6.3 & 7.5 V
10 to 40 V
50V
63 & 75 V
100 to 250 V
.895” Diameter
6.3 & 7.5 V
10 to 40 V
50V
63 & 75 V
100 to 250 V
1.02” Diameter
6.3 & 7.5 V
10 to 40 V
50V
63 & 75 V
100 to 250 V
0.84
0.81
0.76
0.77
0.76
0.88
0.86
0.81
0.81
0.81
1.00
1.00
1.00
1.00
1.00
1.12
1.15
1.23
1.23
1.24
1.17
1.22
1.35
1.35
1.37
1.19
1.25
1.42
1.42
1.44
1.20
1.26
1.44
1.44
1.46
0.82
0.80
0.75
0.75
0.76
0.86
0.84
0.80
0.80
0.81
1.00
1.00
1.00
1.00
1.00
1.14
1.17
1.27
1.26
1.25
1.20
1.25
1.42
1.40
1.38
1.23
1.29
1.50
1.48
1.46
1.24
1.30
1.52
1.50
1.48
0.82
0.78
0.76
0.74
0.76
0.86
0.83
0.81
0.80
0.81
1.00
1.00
1.00
1.00
1.00
1.15
1.20
1.25
1.28
1.24
1.21
1.30
1.38
1.43
1.37
1.24
1.35
1.45
1.52
1.44
1.25
1.36
1.47
1.54
1.46
360 Hz 1 kHz 5 kHz 10 kHz & up
Complies with the EU Directive
2002/95/EC requirement
restricting the use of Lead (Pb),
Mercury (Hg), Cadmium (Cd),
Hexavalent chromium (Cr(VI)),
PolyBrominated Biphenyls
(PBB) and PolyBrominated
Diphenyl Ethers (PBDE).
Load Life:
Shelf Life:
10,000 h at full load at 85 °C
∆ Capacitance ±20%
ESR 200% of limit
DCL 100% of limit
500 h at 105 °C, capacitance, ESR and DCL, initial requirements
CDM Cornell Dubilier • 140 Technology Place • Liberty, SC 29657 • Phone: (864) 843-2277 • Fax: (864) 843-3800 • www.cde.com
What is the principle behind this?
[url=http://www.instructables.com/id/A-Low-Cost-Atomic-Force-Microscope-%E4%BD%8E%E6%88%90%E6%9C%AC%E5%8E%9F%E5%AD%90%E5%8A%9B%E9%A1%AF%E5%BE%AE%E9%8F%A1/]http://www.instructables.com/id/A-Low-Cost-At...
蓝雨夜 Creative Market
Automotive electronic protection circuit
...
zero3360 Automotive Electronics
After the upgrade of ChinaSat 9, there is image but no sound
My phone is ABS-S, and the chipset is: Hi2030E+AVL1108EGa+MAX2119c+3-crystal 12-core panel; the upgrade program is the software of Hi2030E+AVL1108+MAX2119c+3-crystal 12-core panel. After the upgrade, ...
xchromosome Embedded System
[Modelsim FAQ] Error loading design
Cause of the problemThe prompt message indicates that there is no Verilog simulation license, indicating that the software usage license has not been obtained.Even if you use a non-free version of Mod...
小梅哥 FPGA/CPLD
Why is there no SCLK output when TIM4 is read using SPI?
As the title says, in order to synchronize with the slave machine, M4 should actively output the clock to the slave machine....
oursunny Microcontroller MCU
Principle of oscillometric blood pressure signal detection (a common method of measuring blood pressure)
Principle of oscillometric blood pressure signal detection (a common method of measuring blood pressure)First, inflate the cuff, and the cuff blocks the blood flow signal in the blood vessel. When it ...
QWE4562009 Test/Measurement

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 198  2247  660  2380  1151  4  46  14  48  24 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号