EEWORLDEEWORLDEEWORLD

Part Number

Search

56.32.8.060.2380

Description
Electromechanical Relay, DPDT, AC/DC Output
CategoryMechanical and electronic products    relay   
File Size2MB,10 Pages
ManufacturerFINDER
Download Datasheet Parametric View All

56.32.8.060.2380 Overview

Electromechanical Relay, DPDT, AC/DC Output

56.32.8.060.2380 Parametric

Parameter NameAttribute value
MakerFINDER
Reach Compliance Codecompli
body width20.7 mm
body height37.2 mm
Body length or diameter27.7 mm
Coil operating voltage (AC)48 V
Coil resistance1200 Ω
Maximum coil voltage (AC)66 V
Nominal coil voltage60 V
Coil/Input Power TypeAC
Contact (AC) maximum rated R load20A@400VAC
Maximum contact current (AC)20 A
Maximum contact voltage (AC)400 V
Contact/Output Power TypeAC/DC
Dielectric strength between coil and contacts4000 Vrms
Dielectric strength between breaking contacts1000 Vrms
Electrical life100000 Cycle(s)
End contact materialSilver Cadmium Oxide
Number of terminals8
operating hours8 ms
physical size27.7mm x 20.7mm x 37.2mm
GuidelineCSA; IMQ; PCT; UL; VDE
Relay functionDPDT
release time3 ms
Terminal length0.007 inch
Termination typeQUICK CONNECT
56
56 Series - Miniature power relays 12 A
Features
Plug-in - 12 A Power relay, 2 & 4 pole
Flange mount option -
(Faston 187, 4.8x0.5 mm termination)
AC coils & DC coils
Lockable test button and mechanical flag indicator
Cadmium Free contacts (standard version)
Contact material options
96 series sockets
Coil EMC suppression
Accessories
European Patent
SERIES
56.32/56.34
56.32-0300
Plug-in / PCB Relays
1
2 or 4 pole changeover contact
Plug-in/Faston 187
2 pole normally open contact
(≥1.5 mm gap)
Plug-in/Faston 187
56.32
56.32-0300
56.34
* For 4 CO (4PDT) only.
F
OR
UL
RATINGS SEE
:
“General technical information” page
V
Contact specification
Contact configuration
Rated current/Maximum peak current
Rated load AC1
Rated load AC15 (230 V AC)
Single phase motor rating (230 V AC)
Breaking capacity DC1: 30/110/220 V
Minimum switching load
Standard contact material
Coil specification
Nominal voltage (U
N
)
Rated power AC/DC
Operating range
Holding voltage
Must drop-out voltage
Technical data
Mechanical life AC/DC
Electrical life at rated load AC1
Operate/release time
XI-2013, www.findernet.com
56.32
56.34
56.32-0300
2 CO (DPDT)
A
VA
VA
kW
A
12/20
250/400
3,000
700
0.55
4 CO (4PDT)
2NO (DPST-NO) -
≥1.5mm
gap
12/20
250/400
3,000
700
0.55
12/1/0.5
500 (10/5)
AgNi
Rated voltage/Maximum switching voltage V AC
12/0.5/0.25
500 (10/5)
AgNi
mW (V/mA)
V AC (50/60 Hz)
V DC
VA (50 Hz)/W
AC
DC
AC/DC
AC/DC
cycles
cycles
ms
V AC
°C
8/3
4
1.5/1
6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 - 400*
6 - 12 - 24 - 48 - 60 - 110 - 125 - 220
2/1.3
(0.8…1.1)U
N
(0.8…1.1)U
N
(0.85…1.1)U
N
0.8 U
N
/0.6 U
N
0.2 U
N
/0.1 U
N
20 · 10
6
/50 · 10
6
100 · 10
3
10/4
5
1,000
–40…+70
RT I
1.5/—
(0.85…1.1)U
N
0.85 U
N
/—
0.2 U
N
/—
20 · 10
6
/—
100 · 10
3
8/4
4
2,000
–40…+70
RT I
Insulation between coil and contacts (1.2/50 µs) kV
Dielectric strength between open contacts
Ambient temperature range
Environmental protection
Approvals
(according to type)
Detailed explanation and analysis of operation parameters [TI FAE sharing]
[b]Detailed explanation and analysis of operation parameters [TI FAE sharing] [/b] [list] [*][color=rgb(205, 23, 31)][url=http://www.deyisupport.com/question_answer/analog/amplifiers/f/52/t/18865.aspx...
蓝雨夜 Analogue and Mixed Signal
StarterWare Learning Notes for TI Processors Based on C6000 DSP
[i=s]This post was last edited by Jacktang on 2017-10-17 21:47[/i] [p=26, null, left][color=#333333][font=Arial][size=14px]1. Directory structure[/size][/font][/color][/p][p=26, null, left][color=#333...
Jacktang Microcontroller MCU
I really want to participate! Learn!!
I really want to participate! study!!...
lanhua ST MEMS Sensor Creative Design Competition
How to read and write data to iic device?
I would like to ask those who have experience with iic, can iic devices send and receive data through writefile and readfile? Or do I need to use deviceiocontrol? Thank you...
lvjg Embedded System
Wireless coding remote control doorbell production
Compared with traditional doorbells, coded remote control doorbells eliminate the trouble of wiring. Due to the use of encoding and decoding technology, multiple machines do not interfere with each ot...
yuandayuan6999 DIY/Open Source Hardware
Debugging Problems with AT89C51CC01 and JM12864M LCD Modules
Recently, I am working on a vehicle instrument display, which uses the CAN bus to connect the vehicle controller and the display instrument. The part I worked on was the instrument part. Because CAN c...
homer76 51mcu

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1647  997  834  2336  1835  34  21  17  48  37 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号