800-034-ADN2Z18-13NX-12

Description
Cable Assembly, 22AWG,
CategoryThe connector    Connector bracket   
File Size311KB,4 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Environmental Compliance
Download Datasheet Parametric View All

800-034-ADN2Z18-13NX-12 Overview

Cable Assembly, 22AWG,

800-034-ADN2Z18-13NX-12 Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
MakerGlenair
Reach Compliance Codecompli
Conductor surface treatmentSILVER
ConnectorSide1PLUG
ConnectorSide2RECEPTACLE
Connector bracket typeCABLE ASSEMBLY
structureSTRANDED
insulator materialTFE
Jacket materialTHERMOPLASTIC POLYURETHANE
Maximum operating temperature105 °C
Minimum operating temperature-30 °C
shieldYES
Wire gauge22 AWG
800-034
Abrasion-Resistant Polyurethane Jacket
provides cold temperature flexibility and
high strength. Low smoke/zero halogen
material meets requirements for low
toxicity.
90% Tinned Copper Braid
is terminated
directly to connector with stainless steel
BAND-IT®
strap.
Watertight Overmold
provides strain
relief and protection.
C
Series 800 Harsh Environment Shielded Cordsets
These overmolded cordsets withstand abrasion and chemical exposure. Low smoke zero halogen jacket reduces the amount of
toxic and corrosive gasses emitted during combustion. Cable construction features silver coated stranded conductors with TFE
insulation, tinned copper braid shield and extruded polyurethane jacket. Choose single-ended pigtails or double-ended "back-
to-back" versions. Braid shield is attached directly to connector with
BAND-IT®
straps. Semi-rigid polyamide overmold provides
strain relief and environmental sealing.
Series 801 cordsets are now available with size #20HD, #16 and #12 contacts. Ordering information is found on the following
pages.
HARSH ENVIRoNMENt CoRDSEt SpECIFICAtIoNS
Cable Jacket Material
Cable Shield
Conductors
BanD-It®
Shield Termination Band
Current Rating
Test Voltage (Dielectric Withstanding Voltage)
Insulation Resistance
Operating Temperature
Solvent Resistance, Polyamide Overmold
Shielding Effectiveness
Cable jacket Flammability and Toxicity
Thermoplastic Polyurethane, Black, Low-Smoke, Zero-Halogen
Tin-Coated Copper Braid, 90% Minimum Coverage
Silver Coated Stranded Wire, TFE Insulated, Per M22759/11
Stainless Steel
#23 5 Amps, #20HD 7.5 Amps, #16 13 Amps, #12 23 Amps
#23 500 VAC, #20HD 750 VAC, #16 and #12 1800 VAC Sea Level
200 megohms minimum
-30° C. to +105° C.
Excellent Resistance to Most Solvents, Fuels, and Oils; Poor Resistance to
Strong Acids and Bipolar Solvents (Alcohol)
50 dB minimum from 100MHz to 1000MHz.
Toxicity Index 3.9 per NES 713
Oxygen Index 28% per ASTM D-2863
Smoke Index 24 per NES 711
© 2010 Glenair, Inc.
www.glenair.com
Dimensions in inches (millimeters) and are subject to change without notice.
CAGE Code 06324
Printed in U.S.A.
E-Mail: sales@glenair.com
GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497 • 818-247-6000 • FAX 818-500-9912
C-23
7 - MARCH - 2013
Series 800
Series 800 Mighty Mouse with uN Mating thread
overmolded Cordsets
TIG arc welding inverter power supply
Tungsten inert gas welding is a typical inert gas shielded welding method. Under the protection of argon (Ar), the arc heat generated between the tungsten electrode and the workpiece is used to melt t...
zbz0529 Power technology
Model and process of embedded system development
[b]1 Structure of embedded system 1.1 Hardware architecture of embedded system [/b] As shown in Figure 5-1, it is the hardware model structure of embedded system. This system is mainly composed of mic...
soso Embedded System
Common English for Integrated Circuits
Line unit and tributary unitPhase - lockTiming referenceHot plugRinging currentExternal synchronization modeSynchronous holdover modeInternal free - run modePointer justificationJitter ( suppress ) wo...
settleinsh FPGA/CPLD
How far is high-altitude Wi-Fi from us?
As the construction of WIFI hotspots on the ground is in full swing, everyone has begun to turn their attention to the sky. In today's ubiquitous wireless network, airplanes have become the last virgi...
azhiking Wireless Connectivity
The ultimate setup for your next Python project
Whether you are working on some machine learning/AI stuff, building a web app in Flask, or just writing some quick Python scripts, it is always useful to have some templates ready for your project tha...
dcexpert MicroPython Open Source section
請解緊急
請問實體是哪個實體 我一直找不到為何會error 我是直接打成是還要打甚麼嗎 書上都沒寫一直找不到 [img=110,0]https://bbs.eeworld.com.cn/forum.php?mod=image&aid=178013&size=300x300&key=65d1aa8367db7850&nocache=yes&type=fixnone[/img]...
aq62386238 FPGA/CPLD

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1859  1996  1907  12  719  38  41  39  1  15 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号