EEWORLDEEWORLDEEWORLD

Part Number

Search

2122AH1SK

Description
OFF-DELAY RELAY, DPDT, MOMENTARY, 50526mW (COIL), 10A (CONTACT), 30VDC (CONTACT), PANEL MOUNT
CategoryMechanical and electronic products    relay   
File Size283KB,3 Pages
ManufacturerTE Connectivity
Websitehttp://www.te.com
Download Datasheet Parametric View All

2122AH1SK Overview

OFF-DELAY RELAY, DPDT, MOMENTARY, 50526mW (COIL), 10A (CONTACT), 30VDC (CONTACT), PANEL MOUNT

2122AH1SK Parametric

Parameter NameAttribute value
Reach Compliance Codeunknow
ECCN codeEAR99
body width38.6 mm
body height100 mm
Body length or diameter38.6 mm
Coil current (AC) maximum value0.421 A
Coil power50526 mW
Coil resistance285 Ω
Maximum coil voltage (AC)120 V
Coil/Input Power TypeAC
Contact (AC) maximum rated R load10A@120VAC
Maximum contact current (AC)10 A
Maximum contact current (DC)10 A
Contact (DC) maximum rated R load10A@30VDC
Maximum contact voltage (AC)120 V
Maximum contact voltage (DC)30 V
Contact/Output Power TypeAC/DC
Electrical life100000 Cycle(s)
Manufacturer's serial number2100
Installation featuresPANEL MOUNT
Maximum operating temperature85 °C
Minimum operating temperature-55 °C
physical size38.6mm X 38.6mm X 100mm
GuidelineCE; MIL-R-6106E
Relay actionMOMENTARY
Relay functionDPDT
Relay typeOFF-DELAY RELAY
sealHERMETICALLY SEALED
surface mountNO
Termination typeSOLDER
Base Number Matches1
Catalog 1308242
Issued 3-03
AGASTAT
2100
series
Miniature Electropneumatic
Timing Relay
Users should thoroughly review the technical data before selecting a product
part number. It is recommended that users also seek out the pertinent
approvals files of the agencies/laboratories and review them to ensure the
product meets the requirements for a given application.
Design Features
• High Repeat Accuracy over voltage and temperature extremes
• Hermetically sealed units are designed for high shock and vibration
applications
• Instant recycling – easy linear adjustment
• Exclusive Dial Head adjustment – no needle valves
• Delay ranges from milliseconds to 3 minutes
• DPDT contacts
Repeat Accuracy:
NORMAL VERTICAL POSITION
+5% at 25°C; +7% at 85°C; +8% at -55°C.
The average time between -55°C and 85°C will be within +20% of the
average @ 25°C with a proportionally reduced effect at lesser extremes.
In extremely short delay settings an additional 8 msec. variation may result
on AC models due to "half cycle" alternating current effect.
Setting Tolerance:
Factory time setting, when specified, subject to addition-
al +5% tolerance.
Position Sensitivity:
HORIZONTAL POSITION: Approximately 5% increase from the initial time in
the vertical position.
INVERTED POSITION: Approximately 10% increase from the initial time in
the vertical position.
Reset Time:
2112 Series: 25 msec.; 2122 Series: 75 msec.
Relay Release Time:
25 msec. (2112 Series)
Relay Operate Time:
75 msec. (2122 Series)
Operating Voltage:
Coil Data
Nominal Resistance
Operating
Ohms
Code Voltage
±10%
M
N
P
R
Y
12VDC
28VDC
48VDC
110VDC
125VDC
30
131
500
3200
3380
Nominal
Operating
Voltage
Resistance
Ohms
±10%
Design & Construction
Sealed patented timing head
circulates air under controlled pressure
through a variable orifice to provide adjustable timing. Circular-path Dial
Head principle replaces traditional needle valve.
Snap-action switch assembly
provides sustained contact pressure during
timing cycles. Specially designed over center mechanism assures flutter-
free load transfer after extended delay periods.
Precision-wound solenoid assembly
supplies the basic motive force
when the control circuit is closed.
These assemblies are mounted in a rigid self-supporting framework within
a steel enclosure. This rugged construction assures permanent alignment
of all operating members, the key to this unit's long trouble-free operation.
Code
S
S
T
U
Operation
Series 2112 (On-Delay) -
Applying rated voltage to the
solenoid coil starts the preset time delay. At the end of the
delay period the NC contacts break and the NO contacts
make. Contacts remain in this position until the coil is de-
energized, when the switch instantaneously returns to its
original position. De-energizing the coil, either during or
after the delay period, will immediately (within 25 msec.) re-
cycle the unit. It will then provide another full delay period
on re-energization.
Series 2122 (Off-Delay) -
Applying rated voltage to the
coil for at least 75 msec. (for accurate timing) will instanta-
neously transfer the switch, breaking the NC contacts and
making the NO contacts. Contacts remain in this position
as long as the coil is energized. The preset time delay
period begins as soon as the coil is de-energized, at the
end of which the switch returns to its original position.
No power is required during the timing period.
Re-
energizing the coil, either during or after the delay period,
will immediately start a new cycle with full delay period.
120V 60 Hz 190 (2112 Series)
120V 60Hz 285 (2122 Series)
240V 60Hz
765
115V 400Hz
2600
Transients:
Insensitive to transients of +1500 VAC for 10 milliseconds
Dielectric:
1000V RMS @ 60Hz between non-connected terminals.
Contact Rating (DPDT Contacts):
30V
DC
Inductive (Amps)
Resistive (Amps)
2
10
110V
DC
.75
1
120V
60Hz
3
10
120V
400Hz
2
10
240V
60Hz
1.5
5
Based on 100,000 operations electrical, 1,000,000 mechanical. Inductive and
capacitive load should not have inrush currents that exceed five times normal
operating load.
Ambient Temperature Range:
-55°C to +85°C
Weight:
Maximum, any unit - 17 ozs.
Mounting/Terminals:
Chassis mounting tabs, octal plugs and external (-4)
or internal (-5) adjustment. Panel mounting back plate, internal adjustment,
and solder hook terminals (-9).
Operation
(Listed values at nom. voltage, 25°C unless noted).
Operating Mode:
2112:
On-delay (delay on pull-in);
2122:
Off-delay (delay on drop-out)
Timing Adjustment:
All standard models offer easy linear adjustment over
one of nine timing ranges listed below. For applications requiring frequent
readjustment, the external knob model with calibrated dial is recommended.
For tamper-proof installation or where readjustment is infrequent, the internal
key model may be preferred. This model requires removal of the cover plate
for timing adjustment. Hermetically sealed models provide a slotted
adjusting screw under the cap nut on the top cover.
Timing Ranges:
Code
A
B
C
D
E
F
Range
.03 to .1 sec.
.1 to .3 sec.
.15 to 1.0 sec.
.375 to 3.0 sec.
.75 to 10.0 sec.
1.0 to 30.0 sec.
Code
G
H
J
K
L
Range
2.0 to 60.0 sec.
5.0 to 120.0 sec.
5.0 to 180.0 sec.
1.5 to 30.0 cycles
3.0 to 120.0 cycles
--4
--5
--9
These are minimum standards; where more severe environmental
conditions must be met, please consult the factory.
Dimensions are shown for
1254
reference purposes only.
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Specifications and availability
subject to change.
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
iar7.51.A
I am a student doing graduation project. Does anyone have the software iar7.51.A? It is best to crack it. Please send me a copy. Thank you very much! Email: tohappykeke@163.com...
myt88716 RF/Wirelessly
Magnetic materials for sensors
According to the principle of differential transformer sensor, when the two secondary coils of the differential transformer are differentially connected and the iron core is in the middle position, th...
songrisi Sensor
Meteor shower design based on 51 single chip microcomputer, providing schematic diagram and source code
The design principle is simple. The required components are as follows: 1. One stc89s52 microcontroller 2. One 11.0592MHz crystal oscillator 3. Two 30Pf capacitors 4. 24 5mm diameter high brightness w...
vivienluo 51mcu
The first National Sensor Technology Application Exchange Conference and China Sensor Technology Engineers Annual Conference will be held in Beijing
In March 2013, the first National Sensor Technology Application Conference and China Sensor Technology Engineers Annual Conference organized by the China Electronics Society will be held in Beijing. T...
中国电子学会 Embedded System
Newbie help: Can I use ccs to directly read audio files?
As the title says, can I use CCS to directly read WAV files and store the data in an array? Please help me....
shifanno1 DSP and ARM Processors
High current withstand voltage 27VDC-DC step-down IC compatible with CX8505/FR9886 series
[i=s] This post was last edited by lianyiwei11 on 2014-11-14 12:34 [/i] [align=left]LY5523 3A, 30V Synchronous Rectification Buck Regulator [/font] [/align] [align=left]Overview [/align] LY5523 is a s...
lianyiwei11 Power technology

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1694  1440  2509  797  783  35  29  51  17  16 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号