(Above which the useful life may be impaired. For user guidelines, not tested.)
Storage Temperature .......................................................... 65°C to +150°C
Note:
Stresses greater than those listed under MAXIMUM
Ambient Temperature with Power Applied .......................... 40°C to +85°C
RATINGS may cause permanent damage to the
Supply Voltage to Ground Potential (Inputs & Vcc Only) ........ 0.5V to +7.0V device. This is a stress rating only and functional
Supply Voltage to Ground Potential (Outputs & D/O Only) ..... 0.5V to +7.0V operation of the device at these or any other conditions
above those indicated in the operational sections of
DC Input Voltage ................................................................... 0.5V to +7.0V
this specification is not implied. Exposure to absolute
DC Output Current ............................................................................. 120mA maximum rating conditions for extended periods may
Power Dissipation ................................................................................. 0.5W affect reliability.
DC Electrical Characteristics
(Over the Operating Range, T
A
= 40°C to +85°C, V
CC
= 5V ±5%)
Parameters Description
V
IH
V
IL
I
IH
I
IL
I
OZH
V
IK
I
OS
V
H
R
ON
Input HIGH Voltage
Input LOW Voltage
Input HIGH Current
Input LOW Current
High Impedance Output Current
Clamp Diode Voltage
Short Circuit Current
(3)
Input Hysteresis at Control Pins
Switch On Resistance
(4)
V
CC
= Min., V
IN
= 0.0V, I
ON
= 48mA
V
CC
= Min., V
IN
= 2.4V, I
ON
= 15mA
Test Conditions
(1)
Guaranteed Logic HIGH Level
Guaranteed Logic LOW Level
V
CC
= Max., V
IN
= V
CC
V
CC
= Max., V
IN
= GND
0 A, B V
CC
V
CC
= Min., I
IN
= 18mA
A (B) = 0V, B (A) = V
CC
100
150
5
10
7
15
0.7
Min.
2.0
0.5
0.8
±1
±1
±1
1.2
V
mA
m
V
ohm
µA
Typ
(2)
Max.
Units
V
Capacitance
(T
A
= 25°C, f = 1 MHz)
Parameters
(5)
C
IN
C
OFF
C
ON
Description
Input Capacitance
A/B Capacitance, Switch Off
A/B Capacitance, Switch On
Test Conditions
V
IN
= 0V
V
IN
= 0V
V
IN
= 0V
Typ
Max.
6
6
8
Units
pF
Notes:
1. For conditions shown as Max. or Min., use appropriate value specified under Electrical Characteristics for the
applicable device type.
2. Typical values are at V
CC
= 5.0V, T
A
= 25°C ambient and maximum loading.
3. Not more than one output should be shorted at one time. Duration of the test should not exceed one second.
4. Measured by the voltage drop between A and B pin at indicated current through the switch. ON resistance is determined
by the lower of the voltages on the two (A,B) pins.
5. This parameter is determined by device characterization but is not production tested.