Description
Rocker Switch, SPDT, Latched And Momentary, 4A, 30VDC, Solder Terminal, Rocker Actuator, Through Hole-straight
CategoryMechanical and electronic products    switch   
File Size289KB,10 Pages
ManufacturerAPEM
Environmental Compliance  
Download Datasheet Parametric View All

SY232A-6X601U627/1U4602 Overview

Rocker Switch, SPDT, Latched And Momentary, 4A, 30VDC, Solder Terminal, Rocker Actuator, Through Hole-straight

SY232A-6X601U627/1U4602 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerAPEM
Reach Compliance Codecompli
ECCN codeEAR99
Actuator typeROCKER
body width8.2 mm
body height11.7 mm
Body length or diameter15.75 mm
Contact (AC) maximum rated R load5A@125VAC
Maximum contact current (AC)5 A
Maximum contact current (DC)4 A
Contact (DC) maximum rated R load4A@30VDC
Maximum contact voltage (AC)125 V
Maximum contact voltage (DC)30 V
Electrical life40000 Cycle(s)
Manufacturer's serial numberS
Installation featuresTHROUGH HOLE-STRAIGHT
Maximum operating temperature85 °C
Minimum operating temperature-20 °C
method of packingBULK
sealEPOXY TERMINAL SEALED
surface mountNO
Switch actionLATCHED AND MOMENTARY
switch functionSPDT
Switch typeROCKER SWITCH
Termination typeSOLDER
S and SR series
Washable rocker and paddle switches
Distinctive features and specifications
Sealed
• Secure assembly of the two case parts
• Internally sealed bushing
• Epoxy sealed terminals
Process compatible (S series)
• Wave solderable
• Washable
Optional ESD protection
ELECTRICAL SPECIFICATIONS
MATERIALS
D
• Max. current/voltage rating with resistive load :
- silver contacts (A or 1) : 2A 250VAC - 5A 125VAC - 4A 30VDC
- brass, gold plated contacts (CD or 0) : 0,4VA 20VAC or DC
- silver, gold plated contacts (AD or 2) : 2A 250VAC - 5A 125VAC - 4A 30VDC
(300mA 30VDC for gold plating)
• Initial contact resistance : 10 mΩ max.
• Insulation resistance : 1.000 MΩ min.
• Dielectric strength : 1.000 Vrms 50 Hz min.
• Electrical life with nominal load :
Contacts
A or 1
CD or 0
AD or 2
Number of cycles
2 positions
40.000
100.000
40.000
3 positions
40.000
50.000
40.000
• Case and cover : UL94-V0,
polyamide, glass filled or PES
• Actuator : polyamide
• Contacts
CD
or
0
: brass, gold plated
A
or
1
: silver
AD
or
2
: silver, gold plated
• Terminal seal : epoxy
GENERAL SPECIFICATIONS
AGENCY APPROVALS
• Mechanical strength :
Terminals are strengthened by a bracket or a ground plate ensuring the
rigidity of the switch on the board. Actuator strength is 10N max.
• Operating temperature : -20°C to +85°C
• Storage temperature : -40°C to +85°C
• Moisture :
The insulating materials employed and the complete seal permit the switches
to withstand a 56 days moisture test (IEC 68-2-3).
• Soldering - thermal shock (S series only) :
The switches are especially designed for flow soldering at 260°C during
5 seconds owing to high temperature polymer parts.
• Iron soldering (SR series) : 300°C 5 sec. max.
• Solderability : The switches are tested at 235°C according to IEC 68-2-20
after accelerated aging.
Availability
: consult factory for
details of approved models.
Marking
: to order switches
marked UL, complete appropriate
box of ordering format.
D-10
www.apem.com
APEM
MM's work attitude
I listened to the traffic radio this morning, and the main topic today was "fighting". As a result, a girl said that fighting is the worst thing, which hurts the body and costs money. Every time they ...
向农 Talking about work
[Altera SoC Experience Tour] Problems caused by installing multiple versions of Quartus II
I applied for a SoCkit board for trial, so I need to update the Quartus II in my computer. Since I must use ArriaGX devices in my project, I cannot uninstall the previous Quartus II12.1. There are two...
coyoo FPGA/CPLD
Does the STLink working indicator light on the 3-in-1 board when the USB is plugged in?
I recently got a 3-in-1 board and I can't connect it with MDK4.1. I observed that there is an LED on the STlink board. Does it light up when the USB is plugged in? Or does it need to be connected?...
zizimolan stm32/stm8
100W24v output board, change to 12V output
Dear teachers and technical experts:Hello!I now have a 100W 24V output switching power supply, and I want to make a 100W 12V output power supply. I would like to ask, should I modify the 24V board or ...
何生生 Switching Power Supply Study Group
[2013 Young Teachers Summer Training Materials] LaunchPad Pocket Experiment Platform—MSP-EXP430G2.pptx
[size=6][color=#ff0000][b]Download address: This file is large, please download patiently [url]https://download.eeworld.com.cn/detail/qinkaiabc/283462[/url][/b][/color][/size]...
qinkaiabc Microcontroller MCU
Huaqing Vision Course Notes
Huaqing Yuanjian Embedded Course Second Lecture NotesThe second phase is the main course of their training. The quality is pretty good. Interested friends can download it and have a look. It's free!!:...
115515296 ARM Technology

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1740  511  906  393  1012  36  11  19  8  21 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号